Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Yokogawa GM90MB-01N0 is a module base used in the SMARTDAC+ GM modular data acquisition platform. It provides the physical mounting and system-side connection structure needed to integrate compatible GM modules into the overall system architecture.
Unlike measurement modules that process field signals, the GM90MB-01N0 functions as part of the system infrastructure. It establishes the mechanical and electrical interface between the installed module and the SMARTDAC+ GM platform, allowing the corresponding module to be securely integrated into the system.
In a typical installation, the module base is used together with the appropriate SMARTDAC+ GM module and system power arrangement. Its function becomes particularly relevant when assembling a new GM system, adding modules to an existing installation, or replacing a damaged mounting interface during maintenance.
The module base should therefore be selected according to the GM system configuration and the module intended for installation. Correct positioning and connection are important for maintaining proper mechanical engagement and communication or power paths between the installed module and the rest of the system.
| Parameter | Specification |
|---|---|
| Manufacturer | Yokogawa |
| Model | GM90MB-01N0 |
| Product Family | SMARTDAC+ GM |
| Product Type | Module Base |
| System | SMARTDAC+ GM Data Acquisition System |
| Module Function | Module mounting and system interface |
| Application | Mounting compatible SMARTDAC+ GM modules |
| System Role | Modular system infrastructure |
| Installation | SMARTDAC+ GM modular architecture |
| Dimensions | 135 × 57.7 × 103.5 mm |
| Weight | 0.15 kg |
The GM90MB-01N0 acts as the interface between a compatible SMARTDAC+ GM module and the system installation. The module is mounted onto the base, while the base establishes the required physical and system-side connection with the surrounding GM architecture.
Its operation is therefore closely tied to the module installed on it. The base itself does not perform signal measurement or data processing; instead, it allows the functional module to become part of the complete acquisition system.
SMARTDAC+ GM System → GM90MB-01N0 Module Base → Compatible GM Module → Measurement / Data Acquisition Functions
During replacement or system expansion, the base provides the structural foundation needed to position the module correctly and maintain the intended system interface.
The GM90MB-01N0 occupies the modular infrastructure layer of the SMARTDAC+ GM architecture. It connects the installed functional module with the physical and system-side structure of the data acquisition platform.
| System Element | Function |
|---|---|
| GM90MB-01N0 | Provides the mounting and system interface for a compatible GM module |
| SMARTDAC+ GM Module | Performs the applicable measurement, signal interface, or system function |
| GM90PS-1N1D0 | Provides system power within the GM architecture |
| SMARTDAC+ GM Main Unit | Coordinates system operation and data acquisition functions |
| Communication Interface | Transfers system and measurement data to external equipment |
| Field / Test Signals | Provide the source data acquired by the installed functional modules |
| Application | Typical Use |
|---|---|
| Industrial Data Acquisition | Provides the mounting infrastructure for modular GM acquisition systems |
| Process Monitoring | Supports installation of GM modules used for process signal collection |
| Equipment Testing | Used when assembling modular test and measurement equipment |
| Production Monitoring | Provides a physical system interface for modules used in manufacturing data collection |
| Laboratory Measurement | Supports modular GM configurations used for repeatable measurement tasks |
| System Expansion | Allows compatible modules to be integrated into an existing GM installation |
| Component | Function |
|---|---|
| SMARTDAC+ GM Functional Module | Installs on the module base to perform the required system function |
| Yokogawa GM90PS-1N1D0 | Provides system power for the SMARTDAC+ GM architecture |
| SMARTDAC+ GM Main Unit | Provides the central platform for system operation and data acquisition |
| Communication Interface | Connects the GM system with external monitoring or control equipment |
| Module Wiring / Connections | Provides the applicable signal or system connections |
| SMARTDAC+ GM System Hardware | Forms the complete modular installation around the module base |
| Model | Product Type | Typical Application |
|---|---|---|
| Yokogawa GM90MB-01N0 | SMARTDAC+ GM Module Base | Mounting and system interface for compatible GM modules |
| Yokogawa GM90PS-1N1D0 | SMARTDAC+ GM Power Supply Module | System power supply |
| Yokogawa GM10 | SMARTDAC+ GM Data Acquisition Module | Modular data acquisition |
| Yokogawa GX90XA | SMARTDAC+ Analog Input Module | Analog measurement acquisition |
The GM90MB-01N0 is a module base used to mount and interface compatible SMARTDAC+ GM modules with the overall system architecture. It is an infrastructure component rather than a measurement-processing module.
No. The module base itself does not perform the primary signal acquisition function. The functional GM module installed on the base handles the applicable measurement or system task.
The intended GM module compatibility, mounting position, interface condition, mechanical engagement, and surrounding system connections should be checked before the system is powered up.
Yes. A damaged, contaminated, loose, or improperly seated base can affect the physical or system-side connection of the installed module. If a module behaves abnormally after replacement or installation, the base and interface should be inspected as part of the troubleshooting process.