Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE IC641SUG716 Series Six TCP/IP Ethernet Upgrade Disk is a software-related upgrade component for GE Series Six PLC systems. Rather than functioning as a conventional PLC input, output, CPU, or communication interface module, it is associated with upgrading the communication capabilities of an existing Series Six installation.
The purpose of a TCP/IP Ethernet upgrade is to bring Ethernet-based networking capability into a legacy PLC environment, allowing the control system to work with modern network infrastructure where the installed hardware and configuration support the upgrade.
For maintenance and modernization projects, this type of upgrade component can be useful when an existing Series Six controller remains operational but its original communication method no longer fits the plant’s networking requirements. It can help extend the practical service life of legacy automation equipment without immediately replacing the complete PLC system.
Because the IC641SUG716 is an upgrade medium rather than a standalone Ethernet interface module, it should be evaluated together with the target Series Six hardware, applicable firmware or software requirements, and the communication hardware that will ultimately provide the network connection.
| Parameter | Specification |
|---|---|
| Manufacturer | GE |
| Model | IC641SUG716 |
| Product Family | Series Six |
| Product Type | TCP/IP Ethernet Upgrade Disk |
| Primary Function | Ethernet / TCP/IP Communication Upgrade |
| System Role | Communication Upgrade |
| Application | Legacy PLC Networking |
| Installation | GE Series Six Control System |
| Dimensions | 80 × 50 × 20 mm |
| Weight | 0.018 kg |
The IC641SUG716 is focused on extending the networking capabilities of a GE Series Six control environment.
Key characteristics include:
The upgrade should not be treated as a replacement for physical Ethernet hardware. The complete communication architecture still needs the appropriate interface hardware, network connections, configuration, and compatible Series Six equipment.
The IC641SUG716 is associated with the software or configuration upgrade side of Ethernet communication within a Series Six environment.
A simplified communication path can be represented as:
Series Six PLC → Ethernet Communication Hardware → TCP/IP Network → Supervisory / Host System
The upgrade disk supports the transition from a legacy control-system communication environment toward TCP/IP-based Ethernet networking.
In practical terms, the upgrade process may involve loading or applying the required software or system information to compatible Series Six equipment. Once the appropriate communication hardware and configuration are in place, the PLC system can participate in an Ethernet-based network.
The disk itself does not function as an Ethernet switch, network cable, or standalone communication card. Its role is related to enabling the required upgrade within a compatible Series Six architecture.
For this reason, successful implementation depends on more than simply having the upgrade disk available. The target controller, communication interface, software environment, and network configuration should all be checked before beginning the upgrade.
The IC641SUG716 belongs to the communication modernization layer rather than the conventional I/O layer.
A typical upgraded architecture can be viewed as:
Series Six PLC → Ethernet Interface → TCP/IP Network → SCADA / HMI / Engineering Station
This type of architecture allows a legacy PLC installation to participate in an Ethernet-based plant network while retaining the existing control hardware where practical.
The distinction between the upgrade component and the physical Ethernet interface is important. The IC641SUG716 supports the upgrade process, while the actual network connection depends on compatible communication hardware and the surrounding infrastructure.
For plant modernization, this approach can be useful when the control logic and field wiring remain serviceable but the existing communication architecture needs to connect with newer supervisory or engineering systems.
The IC641SUG716 is particularly relevant to facilities maintaining legacy GE Series Six PLC installations.
| Application | Typical Use |
|---|---|
| Factory Automation | Updating legacy PLC communication |
| Process Control | Connecting established PLC systems to Ethernet infrastructure |
| Manufacturing Lines | Modernizing PLC-to-supervisory communication |
| Material Handling | Supporting network integration of legacy controllers |
| Plant Monitoring | Enabling communication with higher-level systems |
| SCADA Integration | Supporting Ethernet-based control-system networking |
| PLC Modernization | Extending the communication capability of existing equipment |
| Legacy System Maintenance | Maintaining older Series Six installations |
The actual implementation depends on the communication hardware and software configuration of the target PLC system.
Because the IC641SUG716 is an upgrade component, preparation is especially important before applying it to an operating control system.
The existing PLC configuration should be documented before beginning the upgrade. This includes controller information, communication hardware, current network connections, software configuration, and any existing communication-dependent applications.
Recommended checks include:
For an operating production system, communication upgrades should be planned as controlled maintenance activities. A communication change can affect SCADA, HMI, engineering stations, data collection, and other systems even when the PLC control logic itself remains unchanged.
The IC641SUG716 works as part of a broader communication architecture rather than operating independently.
| Component | Function |
|---|---|
| GE Series Six PLC | Executes the control application |
| Compatible Ethernet Interface | Provides the physical/network communication path |
| TCP/IP Network | Carries Ethernet-based data |
| Ethernet Switch | Connects networked devices |
| Engineering Workstation | Provides configuration and maintenance access |
| SCADA System | Collects and displays process information |
| HMI | Provides operator interaction |
| Network Cabling | Carries Ethernet communication |
| PLC Program / Configuration | Defines the controller’s operating behavior |
| Plant Network Infrastructure | Connects the PLC system with other automation equipment |
When planning an Ethernet upgrade, all of these elements should be considered as part of the communication chain.
For Series Six communication modernization, related products should be selected according to the required communication function and the existing controller architecture.
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| GE IC641SUG716 | TCP/IP Ethernet Upgrade Disk | Series Six Ethernet communication upgrade |
| GE Series Six Communication Hardware | Communication Hardware | PLC network integration |
| GE Series Six CPU Modules | PLC Controller Hardware | Control program execution |
| GE Series Six I/O Modules | PLC I/O Hardware | Field signal acquisition and control |
| GE Series Six Interface Boards | Interface Hardware | System-level hardware integration |
| Industrial Ethernet Switches | Network Hardware | Connecting PLC and network devices |
The IC641SUG716 should not be confused with a physical Ethernet communication module. When planning a replacement or modernization project, the upgrade component and the required network interface hardware should be evaluated separately.
The IC641SUG716 is associated with a TCP/IP Ethernet communication upgrade for compatible Series Six installations. It is intended to support communication modernization rather than act as a conventional PLC I/O module.
No. The upgrade disk should not be treated as a standalone Ethernet interface. The complete implementation requires compatible Series Six communication hardware and the appropriate Ethernet network infrastructure.
A communication upgrade can change the way the controller interacts with external systems. Keeping a backup of the existing PLC program and configuration provides a recovery point if the upgrade encounters compatibility, configuration, or communication problems.
Testing should extend beyond checking whether the PLC powers up normally. Verify communication between the PLC and its intended network devices, then check SCADA, HMI, engineering-station access, data exchange, and any other applications that depend on the PLC network connection. This confirms that the upgrade works within the complete control-system architecture.