• GE DS200TCTEG1ABA TC2000 Trip Module
  • GE DS200TCTEG1ABA TC2000 Trip Module
  • GE DS200TCTEG1ABA TC2000 Trip Module
  • GE DS200TCTEG1ABA TC2000 Trip Module
Product Overview The GE DS200TCTEG1ABA MARK V TC2000 Trip Module is a specialized turbine protection and trip interface board designed for the GE Mark V Speedtronic turbine control system. It belongs to……
GE DS200TCTEG1ABA TC2000 Trip Module
  • GE
  • DS200TCTEG1ABA
  • TC2000 Trip Module
  • USA
  • 200 × 120 × 35 mm
  • 0.82 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 29

Our advantage

GE DS200TCTEG1ABA TC2000 Trip Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE DS200TCTEG1ABA TC2000 Trip Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE DS200TCTEG1ABA TC2000 Trip Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE DS200TCTEG1ABA TC2000 Trip Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE DS200TCTEG1ABA MARK V TC2000 Trip Module is a specialized turbine protection and trip interface board designed for the GE Mark V Speedtronic turbine control system. It belongs to the DS200 series and is identified by the functional acronym TCTE.

The module is designed to support turbine trip-related functions within the Mark V control architecture. It provides relay-based interface capability for turbine protection and shutdown circuits, allowing control-system logic to interact with dedicated trip and protective equipment.

The DS200TCTEG1ABA is equipped with 20 plug-in relays and multiple signal connectors. These components allow the module to exchange discrete control and trip-related signals with other parts of the turbine control system.

Unlike a general-purpose PLC output module, the DS200TCTEG1ABA is specifically associated with the TC2000 trip function of the GE Mark V architecture. It therefore forms part of a larger turbine protection and control system rather than operating as an independent controller.

The specified dimensions of the DS200TCTEG1ABA are 200 × 120 × 35 mm, with a specified weight of 0.82 kg.

Technical Specifications

Parameter Details
Manufacturer GE
Model DS200TCTEG1ABA
Product Series Mark V DS200
Product Type TC2000 Trip Module
Functional Acronym TCTE
Control System GE Mark V Speedtronic
Main Function Turbine trip and protection interface
Number of Relays 20 plug-in relays
50-Pin Connectors 3
50-Pin Connector IDs JLY, JLX, JLZ
12-Pin Connectors 2
12-Pin Connector IDs JN, JM
Dimensions 200 × 120 × 35 mm
Weight 0.82 kg
Board Type Industrial turbine-control PCB
Installation Mark V control cabinet
Application Turbine protection and trip control
Signal Type Discrete / relay interface
Typical Equipment Gas turbines, steam turbines and power-generation systems
Architecture Mark V turbine control and protection

Function and Working Principle

The primary function of the DS200TCTEG1ABA is to support turbine trip-related functions within the Mark V control system.

A turbine protection system must be capable of responding rapidly when a critical operating condition occurs. Depending on the turbine configuration, trip conditions may involve excessive speed, abnormal pressure, temperature conditions, protection-system inputs, or other predefined shutdown conditions.

The DS200TCTEG1ABA provides relay-based interface capability within this protection architecture.

A simplified signal path can be represented as:

Protection Signal → Mark V Control Architecture → TC2000 Trip Module → Relay Interface → Trip Circuit → Turbine Shutdown Equipment

The module contains 20 plug-in relays, which can be used as part of the discrete trip and protection signal architecture.

The relay circuits can interface with external trip-related equipment and provide the electrical switching required by the turbine protection system.

The exact function of each relay depends on the turbine-specific design and wiring configuration.

The DS200TCTEG1ABA should therefore be considered an important component of the overall turbine protection chain rather than a standalone logic controller.

Role in Industrial Control Systems

The DS200TCTEG1ABA has a specialized role within the turbine trip and protection portion of the GE Mark V architecture.

Normal turbine operation depends on continuous control of fuel, speed, temperature, pressure, valves, and auxiliary equipment. At the same time, the control system must be capable of initiating a controlled shutdown when dangerous or abnormal conditions are detected.

The TC2000 Trip Module provides an interface for these trip-related functions.

The module may work alongside:

  • Mark V control processors
  • Turbine trip circuits
  • Protection sensors
  • Overspeed protection systems
  • Terminal boards
  • Digital I/O interfaces
  • Relay output circuits
  • Solenoid trip devices
  • Emergency shutdown circuits
  • Turbine control cabinets

The board does not independently replace the complete turbine protection system. Instead, it forms part of the electrical and control interface used to execute turbine trip functions.

Its position in the system makes accurate wiring and correct board identification particularly important during maintenance.

Industrial Applications

The GE DS200TCTEG1ABA is primarily associated with GE Mark V Speedtronic turbine control systems.

Typical applications include:

  • Gas turbine control
  • Steam turbine control
  • Combined-cycle power plants
  • Turbine generator systems
  • Industrial turbine packages
  • Mechanical-drive turbine systems
  • Compressor-drive turbines
  • Power-generation automation
  • Turbine protection systems
  • Emergency shutdown systems
  • Turbine trip circuits
  • Legacy GE Speedtronic installations

In a gas turbine application, protection systems must respond to abnormal operating conditions while maintaining a reliable control path.

The DS200TCTEG1ABA can form part of this protection architecture by providing relay-based interfaces between the Mark V control system and associated trip circuits.

This makes the module particularly important in applications where reliable turbine shutdown and protection functions are required.

Installation and System Integration

Correct installation of the DS200TCTEG1ABA is essential because the module can be connected to turbine protection and trip circuits.

Before replacing an existing module, technicians should document the original wiring configuration and verify the complete board identification.

Recommended installation procedures include:

  1. Follow the approved turbine shutdown procedure.
  2. Isolate the appropriate control-system power.
  3. Verify the complete DS200TCTEG1ABA part number.
  4. Record the board revision information.
  5. Document all connector positions.
  6. Identify the JLY, JLX and JLZ connectors.
  7. Identify the JN and JM connectors.
  8. Record the original cable orientation.
  9. Inspect the replacement board for physical damage.
  10. Check connectors and relay components.
  11. Install the module in the designated Mark V cabinet location.
  12. Reconnect all cables according to the original configuration.
  13. Verify associated terminal-board connections.
  14. Restore power according to the approved procedure.
  15. Check Mark V diagnostic indications.
  16. Verify the trip-related signal paths.
  17. Test relay operation according to approved procedures.
  18. Complete system-level protection testing before returning the turbine to service.

The module should be handled using appropriate electrostatic-discharge precautions.

Because trip circuits are safety-critical, technicians should not rely solely on physical connector similarity when installing a replacement. The complete part number, revision, wiring arrangement, and system documentation should be verified.

Compatible System Components

The DS200TCTEG1ABA operates as part of a larger turbine control and protection architecture.

Component Function
Mark V Control Processor Executes turbine-control logic
Digital I/O Hardware Transfers discrete control and status signals
Terminal Boards Provide field wiring interfaces
Trip Circuits Carry turbine shutdown commands
Overspeed Protection Detects excessive turbine speed
Protection Sensors Monitor critical operating conditions
Solenoid Trip Devices Execute shutdown-related actions
Relay Output Boards Provide additional discrete output interfaces
Emergency Shutdown Circuits Support rapid turbine shutdown
Turbine Control Cabinet Houses control and protection hardware

The exact combination of components depends on the individual turbine and Mark V system configuration.

Recommended Alternative Models

The following models may be considered when evaluating related GE Mark V turbine trip and protection hardware:

Model Type Key Feature Application
DS200TCTEG1ABA TC2000 Trip Module 20 plug-in relays Mark V turbine trip
DS200TCTEG1A TC2000 Trip Module Related TCTE architecture Turbine protection
DS200TCTEG1 TC2000 Trip Module Original TCTE configuration Mark V trip systems
DS200TCTGG1AFF Simplex Trip Board Turbine trip interface Mark V protection
DS200TCTGG1AEC Simplex Trip Board Trip-system interface Turbine protection
DS200TCTSG1A Simplex Trip Card Dedicated trip function Mark V turbine systems

These models belong to related GE Mark V trip and protection hardware families, but they should not automatically be treated as direct replacements.

Different trip boards may have different signal assignments, relay configurations, connector arrangements, and system architectures.

For safety-critical turbine applications, the replacement should always be selected according to the complete original part number and the specific Mark V configuration.

Key Advantages

The GE DS200TCTEG1ABA provides several advantages for Mark V turbine-control applications:

  • Provides dedicated TC2000 trip interface functionality
  • Supports turbine protection architecture
  • Includes 20 plug-in relays
  • Provides multiple signal connectors
  • Supports discrete trip-related circuits
  • Interfaces Mark V control logic with external protection equipment
  • Supports turbine shutdown functions
  • Integrates into existing Mark V control cabinets
  • Suitable for gas and steam turbine applications
  • Supports maintenance of legacy GE Speedtronic systems
  • Provides a compact dedicated trip-module solution

Its primary advantage is its dedicated role in the turbine trip interface, allowing the existing Mark V architecture to coordinate control and protection functions through relay-based circuits.

Technical FAQs

What is GE DS200TCTEG1ABA?

The GE DS200TCTEG1ABA is a MARK V TC2000 Trip Module designed for turbine trip and protection interface functions.

What is the main function of DS200TCTEG1ABA?

Its primary function is to provide relay-based interface capability for turbine trip and protection circuits within the GE Mark V architecture.

How many relays does DS200TCTEG1ABA have?

The module contains 20 plug-in relays.

What are the dimensions of DS200TCTEG1ABA?

The specified dimensions are 200 × 120 × 35 mm.

What is the weight of DS200TCTEG1ABA?

The specified weight is 0.82 kg.

What connectors are used on DS200TCTEG1ABA?

The module has three 50-pin connectors identified as JLY, JLX and JLZ, together with two 12-pin connectors identified as JN and JM.

Is DS200TCTEG1ABA a PLC processor?

No. It is a dedicated TC2000 trip interface module within the Mark V turbine control architecture.

What is the DS200TCTEG1ABA used for?

It is used to support turbine trip, protection, shutdown, and other discrete relay-interface functions according to the turbine-specific Mark V configuration.

Can DS200TCTGG1AFF replace DS200TCTEG1ABA?

It should not automatically be considered a direct replacement. Although both are associated with turbine trip functions, their hardware configurations and system assignments can differ.

What should be checked before replacing DS200TCTEG1ABA?

Technicians should verify the complete part number, board revision, connector arrangement, relay configuration, terminal-board wiring, trip logic, and Mark V system documentation.

Why is correct replacement important for this module?

The board can participate in turbine trip and protection circuits. Incorrect hardware or wiring can affect shutdown-related functions, so replacement should be performed only after complete compatibility and system checks.

Conclusion

The GE DS200TCTEG1ABA MARK V TC2000 Trip Module is a specialized turbine protection and trip-interface component designed for GE Mark V Speedtronic control systems.

With 20 plug-in relays, three 50-pin connectors, and two 12-pin connectors, the module provides a dedicated interface between Mark V control architecture and turbine trip-related electrical circuits.

The specified dimensions are 200 × 120 × 35 mm, with a weight of 0.82 kg.

The DS200TCTEG1ABA works together with Mark V processors, digital I/O hardware, terminal boards, protection sensors, trip circuits, solenoid devices, and other turbine-control components.

For maintenance engineers, system integrators, and procurement teams, accurate identification of the complete DS200TCTEG1ABA part number is essential. Related Mark V trip boards may appear similar while having different relay configurations, signal assignments, revisions, and applications.

When correctly matched with the existing turbine configuration, the DS200TCTEG1ABA provides a practical interface solution for maintaining the trip and protection functions of legacy GE Mark V turbine control systems.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501