• GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay
  • GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay
  • GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay
  • GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay
Product Overview The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay is a multifunctional protection and control device designed for industrial power distribution systems. It provid……
GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay
  • GE
  • 350-C-P5-G5-H-S-M-N-P-SN-D-N
  • Multilin 350 Feeder Protection Relay
  • USA
  • 201.51 × 168.2 × 244.2 mm
  • 4.1 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 23

Our advantage

GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay is a multifunctional protection and control device designed for industrial power distribution systems. It provides reliable feeder protection, monitoring, control, and fault management functions for electrical networks.

Designed for demanding industrial environments, the Multilin 350 relay continuously monitors electrical operating conditions and provides fast response when abnormal conditions occur. It integrates protection functions, measurement capability, programmable logic, and communication features into a compact relay solution.

The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N is widely applied in feeder protection systems, switchgear applications, industrial power networks, and electrical control installations.

With dimensions of 201.51 × 168.2 × 244.2 mm and a weight of 4.1 kg, this relay provides a practical solution for panel-mounted protection applications where reliability, flexibility, and efficient installation are required.


Technical Specifications

Parameter Details
Manufacturer GE
Model Number 350-C-P5-G5-H-S-M-N-P-SN-D-N
Product Type Multilin 350 Feeder Protection Relay
Application Feeder protection and control
System Type Industrial electrical distribution system
Protection Function Overcurrent and feeder fault protection
Current Input 5 A configuration
Ground Current Input 5 A configuration
Power Supply High voltage power supply configuration
Control Function Protection logic and feeder control
Communication Function Industrial communication interface
Installation Type Panel and switchgear mounting
Dimensions 201.51 × 168.2 × 244.2 mm
Weight 4.1 kg
Operating Environment Industrial electrical applications

Product Function

The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay is designed to perform the following functions:

  • Protect electrical feeders against abnormal conditions
  • Monitor current and electrical system status
  • Detect feeder faults quickly
  • Provide circuit breaker control functions
  • Support protection coordination
  • Improve power distribution system reliability

The relay continuously analyzes electrical system conditions and initiates protective actions when faults occur, helping minimize equipment damage and reduce operational interruptions.


Key Features

1. Reliable Feeder Protection

The Multilin 350 relay provides protection functions for industrial feeder applications.

Main protection capabilities include:

  • Phase overcurrent protection
  • Ground fault protection
  • Feeder fault detection
  • Electrical equipment protection
  • Circuit breaker trip control

These functions help maintain stable operation and improve the safety of electrical distribution systems.


2. Integrated Monitoring and Control

The GE 350 relay combines protection, monitoring, and control functions in a single device.

Key benefits include:

  • Real-time system monitoring
  • Electrical parameter measurement
  • Fault condition analysis
  • Control output management
  • Improved maintenance efficiency

The integrated design reduces system complexity and provides easier operation for engineers and technicians.


3. Flexible Industrial Communication

The relay supports communication integration with industrial automation systems.

Communication functions allow:

  • Remote monitoring
  • System data exchange
  • Integration with control platforms
  • Improved operation visibility

This makes the relay suitable for modern electrical automation environments.


4. Compact Panel Installation Design

The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N features a compact structure.

Advantages include:

  • Reduced installation space requirements
  • Easy integration into protection cabinets
  • Convenient wiring arrangement
  • Suitable for replacement projects

The 4.1 kg lightweight design simplifies handling and installation during maintenance activities.


System Applications

The GE Multilin 350 Feeder Protection Relay is commonly used in:

  • Industrial power distribution systems
  • Medium-voltage switchgear
  • Electrical substations
  • Manufacturing plants
  • Power generation facilities
  • Transformer feeder protection systems
  • Motor feeder protection applications
  • Industrial automation power systems

Installation & Integration

Recommended installation procedures:

  1. Install the relay into the designated protection panel.
  2. Connect current transformer inputs and control wiring.
  3. Connect communication cables.
  4. Configure protection parameters.
  5. Verify input and output signals.
  6. Perform protection testing before operation.

Correct installation ensures accurate fault detection and reliable protection performance.


Compatible Equipment

The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N relay can be integrated with:

  • GE Multilin protection systems
  • Circuit breakers
  • Current transformers
  • Switchgear equipment
  • Industrial control systems
  • Power monitoring systems
  • Substation automation equipment

Advantages

  • High reliability feeder protection
  • Integrated protection and control functions
  • Suitable for industrial power applications
  • Compact and durable design
  • Flexible system integration
  • Improved electrical safety
  • Reduced equipment downtime
  • Easy maintenance and troubleshooting

Common Fault Diagnosis

1. Relay Power Failure

Possible Causes:

  • Incorrect auxiliary power connection
  • Power supply interruption
  • Internal hardware fault

Recommended Checks:

  • Check auxiliary power input
  • Inspect wiring connections
  • Verify relay status indicators

2. Incorrect Protection Operation

Possible Causes:

  • Incorrect protection settings
  • Current transformer wiring errors
  • Improper configuration

Recommended Checks:

  • Review protection parameters
  • Check CT wiring
  • Perform relay testing

3. Communication Failure

Possible Causes:

  • Communication cable problem
  • Incorrect communication settings
  • Network connection issue

Recommended Checks:

  • Inspect communication cables
  • Verify communication parameters
  • Check connected devices

4. Abnormal Measurement Values

Possible Causes:

  • Incorrect input connection
  • Current transformer polarity problem
  • Configuration error

Recommended Checks:

  • Verify measurement inputs
  • Check wiring polarity
  • Review system configuration

FAQs

Q1: What is GE 350-C-P5-G5-H-S-M-N-P-SN-D-N used for?
The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N is used for feeder protection, monitoring, and control in industrial electrical systems.

Q2: What type of faults can this relay detect?
It can detect feeder-related electrical faults such as overcurrent and ground fault conditions.

Q3: Where is this relay installed?
It is commonly installed in switchgear panels, protection cabinets, and industrial power control systems.

Q4: What is the weight of GE 350-C-P5-G5-H-S-M-N-P-SN-D-N?
The relay weighs approximately 4.1 kg.

Q5: What are the main advantages of this relay?
It provides reliable protection, monitoring capability, communication integration, and improved electrical system stability.


Conclusion

The GE 350-C-P5-G5-H-S-M-N-P-SN-D-N Multilin 350 Feeder Protection Relay is a reliable solution for industrial electrical protection applications. With integrated feeder protection, monitoring, control functions, and flexible installation capability, it helps improve power system safety, operational reliability, and maintenance efficiency.

Its compact design and comprehensive protection features make it suitable for industrial plants, switchgear systems, and electrical distribution networks requiring dependable protection performance.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501