• Yokogawa AMM12-S3 Voltage Input Multiplexer Module
  • Yokogawa AMM12-S3 Voltage Input Multiplexer Module
  • Yokogawa AMM12-S3 Voltage Input Multiplexer Module
  • Yokogawa AMM12-S3 Voltage Input Multiplexer Module
Yokogawa AMM12-S3 Voltage Input Multiplexer Module Product Description The Yokogawa AMM12-S3 is a highly reliable and accurate voltage input multiplexer module designed to handle multiple input signals ……
Yokogawa AMM12-S3 Voltage Input Multiplexer Module
  • Yokogawa
  • AMM12-S3
  • Voltage Input Multiplexer Module
  • Japan
  • 45 × 97 × 103 mm
  • 0.3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail sales@xm-automation.com
Mobile +8613620394314
Whatsapp +8613620394314
WeChat 13620394314

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Product Description

The Yokogawa AMM12-S3 is a highly reliable and accurate voltage input multiplexer module designed to handle multiple input signals and provide efficient data acquisition. This module is ideal for applications that require the measurement and monitoring of multiple voltage signals from field devices, allowing for effective control and automation in complex industrial environments. The AMM12-S3 is equipped with the ability to handle up to 12 voltage inputs, making it a versatile solution for various industrial automation systems.

Compact in size (45 × 97 × 103 mm) and lightweight (0.3 kg), the AMM12-S3 integrates seamlessly into Yokogawa’s modular systems and can be easily mounted in control panels or installed on DIN rails. It supports a wide input voltage range, offering flexibility in a variety of applications such as process control, data acquisition, and remote monitoring.

The AMM12-S3 is designed to provide high accuracy and stability, ensuring that voltage measurements are precise and reliable, even in harsh industrial environments. Its modular design also allows easy integration with other modules, providing a scalable solution for expanding measurement capabilities.

Product Specifications

Specification Details
Dimensions 45 × 97 × 103 mm
Weight 0.3 kg
Input Channels Up to 12 voltage inputs
Input Voltage Range ±10 VDC to ±100 VDC
Sampling Rate 200 samples per second
Power Supply 24 VDC ± 20%
Accuracy ±0.1% of full scale
Mounting DIN rail or panel mountable
Interface Modbus RTU
Operating Temperature -20°C to +60°C
Environmental Rating IP20
Compliance CE, UL certified

Product Applications

The AMM12-S3 voltage input multiplexer module is ideal for a wide range of industrial applications where multiple voltage signals need to be measured and processed simultaneously. Common applications include:

  • Process Control Systems: Used to monitor and control multiple parameters such as temperature, pressure, and flow rates, especially in industries like oil & gas, chemical, and pharmaceuticals.

  • Data Acquisition Systems: Facilitates the collection of voltage data from sensors and devices for analysis and decision-making, enabling real-time monitoring and system optimization.

  • Test and Measurement Equipment: Ideal for laboratories and test facilities that require precise voltage measurements for testing electronic components, circuits, and devices.

  • Automation Systems: Works as part of automated systems that require multiple voltage inputs to regulate processes or machinery operations in manufacturing and production.

  • Remote Monitoring: Useful in applications where remote data collection is necessary, such as in energy management or environmental monitoring.

Product Advantages

  • High-Channel Count: The AMM12-S3 supports up to 12 voltage inputs, making it ideal for systems that require multiple input channels to be monitored simultaneously.

  • Compact and Space-Saving: With its small size (45 × 97 × 103 mm), it is perfect for installations where space is limited, such as in control panels or small enclosures.

  • High Accuracy: With an accuracy of ±0.1% of full scale, the module ensures precise measurements of voltage signals, which is essential for maintaining system reliability and performance.

  • Easy Integration: It seamlessly integrates with other Yokogawa modules and systems, providing a flexible and scalable solution for expanding system capabilities.

  • Versatile Voltage Range: The module supports a wide input voltage range (±10 VDC to ±100 VDC), making it suitable for a variety of applications and field devices.

  • Durable and Reliable: Designed for harsh industrial environments, the module operates within a wide temperature range of -20°C to +60°C, providing durability and reliability under challenging conditions.

  • Modbus RTU Communication: Supports Modbus RTU for easy integration with other industrial systems, enabling data transfer and remote access.

Brand Information

Yokogawa is a leading global provider of industrial automation, control, and measurement solutions. With a reputation for reliability, precision, and innovation, Yokogawa’s products help businesses optimize their industrial processes. From process control and automation to measurement and analysis, Yokogawa’s extensive portfolio of solutions ensures that industries such as oil & gas, energy, manufacturing, and chemicals can operate more efficiently and safely. The AMM12-S3 is a key part of Yokogawa’s modular I/O systems, offering reliable voltage measurement and integration for a variety of industrial applications.


Recommended Related Models from the AMM Series

Model Description Specifications
AMM11-S3 Single-channel I/O communication module 45 × 97 × 103 mm; 0.3 kg; ±10 VDC to ±100 VDC
AMM12T Advanced voltage input module with high-speed sampling 45 × 97 × 103 mm; 0.3 kg; ±10 VDC to ±100 VDC
AMM14-S3 Multi-channel I/O communication module with extended range 45 × 97 × 103 mm; 0.4 kg; ±10 VDC to ±100 VDC
AMM15-S3 High-accuracy I/O module with additional digital channels 45 × 97 × 103 mm; 0.35 kg; ±10 VDC to ±100 VDC
AMM10-S3 Basic voltage input module for small-scale applications 45 × 97 × 103 mm; 0.3 kg; ±10 VDC to ±100 VDC

Recommended Popular Models from Yokogawa

Model Number Description Input/Output Type Dimensions (mm) Weight (kg)
ALR121-SE1 Serial Communication Module Serial (RS-485/422) 130 × 126.7 × 32.8 0.3
ADV161-P50 Multi-Input Signal Converter Voltage/Current 100 × 90 × 50 0.2
ADV159-P01 Multi-Input Signal Converter Voltage/Current 120 × 90 × 45 0.3
AMM12-S3 Voltage Input Multiplexer Module Voltage 45 × 97 × 103 0.3
AMM22C Voltage Input Multiplexer Module Voltage 40 × 100 × 90 0.4


FAQ (Frequently Asked Questions)

  1. Q: What is the primary function of the AMM12-S3?
    A: It is a voltage input multiplexer module designed to handle multiple voltage inputs in industrial automation and control systems.

  2. Q: How many input channels does the AMM12-S3 support?
    A: The module supports up to 12 voltage inputs.

  3. Q: What is the input voltage range for the AMM12-S3?
    A: The module can handle inputs from ±10 VDC to ±100 VDC.

  4. Q: What is the sampling rate of the AMM12-S3?
    A: It can sample up to 200 times per second.

  5. Q: What is the power consumption of the AMM12-S3?
    A: The module consumes approximately 3.5W of power.

  6. Q: How is the AMM12-S3 mounted?
    A: The module can be mounted on DIN rails or directly on panels.

  7. Q: What is the communication protocol supported by the AMM12-S3?
    A: The module supports Modbus RTU for communication with other systems.

  8. Q: Can the AMM12-S3 operate in extreme temperatures?
    A: Yes, it has an operating temperature range of -20°C to +60°C, making it suitable for various industrial environments.

  9. Q: What is the accuracy of the AMM12-S3?
    A: The module has an accuracy of ±0.1% of full scale.

  10. Q: Can the AMM12-S3 be used in energy management systems?
    A: Yes, it is ideal for monitoring voltage inputs in energy management systems.


Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Authenticity guarantee

All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Free warehouse

We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Technical Team

Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.

Yokogawa AMM12-S3 Voltage Input Multiplexer Module

Thoughtful after-sales service

24-hour after-sales service guarantee team, professional and standardized management service system.


Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501