The Siemens 6ES7545-5DA00-0AB0 SIMATIC ET 200SP PROFIBUS DP Communication Module is a CM DP communication module that connects an ET 200SP CPU to a PROFIBUS DP network. It adds a dedicated RS485 fieldbus interface to the distributed I/O system, allowing the ET 200SP controller to exchange process data with other PROFIBUS-compatible automation equipment.
Unlike the point-to-point communication modules used for connecting individual serial instruments, the CM DP handles communication across a PROFIBUS DP fieldbus. It can operate as either a DP Master or a DP Slave, depending on the configured application. This makes it suitable for different control architectures, from managing distributed I/O stations to exchanging data with a higher-level PROFIBUS controller.
The module is installed directly to the right of a compatible ET 200SP CPU. Its external PROFIBUS connection uses a 9-pin D-sub socket, while communication with the CPU takes place through the ET 200SP backplane bus.
A typical application is a production line containing several distributed I/O stations. The central controller can use the CM DP as a PROFIBUS DP Master to communicate with remote DP devices installed near motors, conveyor sections, pneumatic equipment, and machine sensors. Instead of routing every field signal back to the main control cabinet, the distributed stations collect local signals and exchange process data over the PROFIBUS network.
The module supports transmission rates up to 12 Mbit/s and can manage up to 125 DP slaves when operating as a DP Master. Automatic baud rate detection simplifies network commissioning by identifying the transmission rate used on the PROFIBUS segment.
Another useful feature is its support for DPV1 communication services. This allows the system to exchange acyclic data records in addition to the cyclic process data used for normal control operations. Engineers can therefore access device parameters and diagnostic information without treating every communication task as part of the regular I/O update cycle.
The CM DP also supports S7 communication, PG/OP communication, routing, and diagnostic functions. These capabilities are useful when the PROFIBUS network needs to support both machine control and engineering access.
One configuration detail deserves attention: the module operates alternatively as a DP Master or DP Slave, not in both roles simultaneously. The selected operating mode must match the intended network architecture and the capabilities of the connected ET 200SP CPU.
For maintenance engineers working with distributed automation systems, the 6ES7545-5DA00-0AB0 is particularly relevant when PROFIBUS DP connectivity needs to be added to an ET 200SP control station.
| Parameter | Specification |
|---|---|
| Manufacturer | Siemens |
| Model | 6ES7545-5DA00-0AB0 |
| Product Type | CM PROFIBUS DP Communication Module |
| Product Family | SIMATIC ET 200SP |
| Communication Interface | PROFIBUS DP |
| Interface Hardware | RS485 |
| Connector Type | 9-Pin D-sub Socket |
| Operating Mode | DP Master / DP Slave |
| Maximum Transmission Rate | 12 Mbit/s |
| Maximum Number of DP Slaves | 125 |
| Automatic Baud Rate Detection | Yes |
| Maximum Cable Length | 100 m |
| Communication Standard | PROFIBUS DP / DPV1 |
| Maximum Address Area | 120 |
| Maximum User Data per Address Area | 128 Bytes |
| Transfer Memory – Inputs | 244 Bytes |
| Transfer Memory – Outputs | 244 Bytes |
| Communication Services | S7 Communication, PG/OP Communication, Routing |
| Diagnostic Functions | Module Diagnostics, Line Diagnostics |
| Supply Voltage | 24 V DC |
| Permissible Supply Voltage Range | 19.2–28.8 V DC |
| Reverse Polarity Protection | Yes |
| Electrical Isolation | Between Backplane Bus and PROFIBUS Interface |
| Mounting Type | ET 200SP Station / Standard DIN Rail |
| Configuration Software | STEP 7 / TIA Portal |
| TIA Portal Compatibility | V13 Update 3 or Later |
| Protection Rating | IP20 |
| Dimensions | 35 × 117 × 75 mm |
| Weight | 0.104 kg |
The 6ES7545-5DA00-0AB0 operates as the PROFIBUS communication interface for an ET 200SP CPU. It handles the exchange of data between the distributed I/O controller and devices connected to the PROFIBUS DP network.
The basic communication path is:
ET 200SP CPU → Backplane Bus → CM DP Communication Module → RS485 Interface → PROFIBUS DP Network → Connected DP Devices
The way the module handles communication depends on whether it is configured as a Master or Slave.
When operating as a DP Master, the module manages communication with configured DP slave devices. It initiates cyclic data exchange, reads input information, and transfers output data according to the configured network arrangement. The ET 200SP CPU can then use the received process values in its control program.
For example, a manufacturing system may use remote I/O stations to collect signals from conveyor sensors and motor control equipment. The CM DP communicates with these stations over PROFIBUS DP, allowing the controller to receive operating conditions and send output commands without requiring individual field signals to return directly to the central cabinet.
When operating as a DP Slave, the module exchanges data with an external DP Master. The ET 200SP station makes its configured input and output data available through the PROFIBUS connection. This arrangement is useful when an ET 200SP station needs to operate as a distributed subsystem under a higher-level PLC.
The module supports cyclic process data exchange as well as DPV1 acyclic communication. Cyclic communication handles the regular exchange of machine signals, while acyclic services allow access to additional device information, parameters, and diagnostic records.
Automatic baud rate detection identifies the transmission rate of the PROFIBUS network. The supported maximum is 12 Mbit/s, although the actual network rate depends on the configuration and connected devices.
The RS485 interface carries the PROFIBUS signals over the bus cable. Correct cable routing, bus termination, connector installation, and network topology are necessary to prevent communication interruptions, particularly in installations containing multiple distributed stations.
An important configuration point is that DP Master and DP Slave operation are alternative modes. The module must be configured for the required role before the PROFIBUS network is commissioned.
The 6ES7545-5DA00-0AB0 provides the PROFIBUS DP connection for an ET 200SP CPU. It extends the station’s communication capabilities beyond its local I/O arrangement and allows the controller to participate in a larger distributed automation network.
A typical Master configuration follows this structure:
Central Automation System → PROFIBUS DP Network → CM DP Master → ET 200SP CPU → Local I/O Modules
In a Slave configuration, the communication direction is arranged around an external PROFIBUS Master:
Higher-Level PLC / DP Master → PROFIBUS DP Network → CM DP Slave → ET 200SP CPU → Local I/O Modules
| System Component | Function |
|---|---|
| Siemens 6ES7545-5DA00-0AB0 | Provides PROFIBUS DP Master or Slave communication |
| ET 200SP CPU | Executes the control program and manages local I/O operations |
| ET 200SP BaseUnits | Provide electrical and mechanical connections for I/O modules |
| ET 200SP I/O Modules | Acquire field signals and control connected equipment |
| PROFIBUS DP Cable | Carries fieldbus communication signals |
| PROFIBUS D-sub Connector | Provides the physical network connection |
| Remote ET 200SP Station | Collects distributed process signals |
| PROFIBUS DP Slave Devices | Exchange cyclic process data with the Master |
| Higher-Level PLC | Coordinates machine or process control |
| Engineering Station | Supports hardware configuration, diagnostics, and maintenance |
The module is especially useful in systems where the ET 200SP platform needs to communicate with existing PROFIBUS-based automation equipment. It allows the distributed I/O station to participate in the established fieldbus architecture without changing the entire network to another communication standard.
In Master operation, the CM DP handles the communication relationship with configured slave devices. In Slave operation, it makes the ET 200SP station’s process data available to an external controller.
This distinction should be considered when selecting the module for a replacement or expansion project, since the required communication role determines the network configuration and engineering arrangement.
| Application | Typical Use |
|---|---|
| Automotive Manufacturing | Connecting distributed I/O stations and machine control equipment through PROFIBUS DP |
| Packaging Lines | Exchanging sensor and actuator signals between remote stations and the main controller |
| Conveyor Systems | Coordinating distributed motor control and conveyor monitoring equipment |
| Process Automation | Connecting remote measurement and control stations to a PROFIBUS network |
| Water Treatment | Integrating distributed pumping and monitoring stations |
| Material Handling | Communicating with remote I/O stations across warehouse and production equipment |
| Machine Building | Adding PROFIBUS DP connectivity to ET 200SP-based control cabinets |
| Power Generation | Exchanging process information between distributed automation stations |
| Production Monitoring | Collecting equipment status and diagnostic information from PROFIBUS devices |
| Industrial System Modernization | Integrating ET 200SP stations into existing PROFIBUS DP installations |
| Component | Function |
|---|---|
| Siemens 6ES7545-5DA00-0AB0 | ET 200SP CM DP PROFIBUS communication module |
| SIMATIC ET 200SP CPU | Controls the distributed I/O station |
| ET 200SP BaseUnits | Provide mounting and electrical connections for I/O modules |
| ET 200SP Digital Input Modules | Acquire signals from field sensors and switches |
| ET 200SP Digital Output Modules | Control actuators, relays, and other output devices |
| ET 200SP Analog Input Modules | Acquire analog process measurements |
| ET 200SP Analog Output Modules | Provide analog control signals |
| PROFIBUS DP Cable | Transfers fieldbus communication data |
| PROFIBUS 9-Pin D-sub Connector | Provides the physical RS485 network connection |
| PROFIBUS DP Remote I/O Station | Exchanges distributed input and output data |
| SIMATIC S7-1500 PLC | Acts as a higher-level controller or PROFIBUS communication partner |
| STEP 7 / TIA Portal | Configures and diagnoses the automation system |
| Model / Product | Product Type | Typical Application |
|---|---|---|
| Siemens 6ES7137-6AA01-0BA0 | SIMATIC ET 200SP CM PtP Communication Module | RS232 and RS422/485 point-to-point communication |
| Siemens 6ES7137-6BD00-0BA0 | SIMATIC ET 200SP CM AS-i Master | AS-Interface network integration |
| Siemens 6ES7137-6BA00-0BA0 | SIMATIC ET 200SP CM IO-Link Master | IO-Link device communication |
| Siemens 6ES7510-1DJ01-0AB0 | SIMATIC ET 200SP CPU 1510SP-1 PN | Distributed control and PROFINET communication |
| Siemens 6ES7512-1DK01-0AB0 | SIMATIC ET 200SP CPU 1512SP-1 PN | Higher-performance ET 200SP control applications |
| Siemens 6ES7193-6BP00-0DA0 | SIMATIC ET 200SP BaseUnit | Mechanical and electrical connection of ET 200SP I/O modules |
No. The CM DP supports alternative operation as either a DP Master or a DP Slave. The required operating mode must be selected during hardware configuration in STEP 7 or TIA Portal. The network architecture and connected equipment determine which role is appropriate.
When configured as a DP Master, the module supports up to 125 DP slaves. The actual network configuration must also account for the available PROFIBUS addresses, device capabilities, communication timing, and the process data requirements of the connected equipment.
The maximum PROFIBUS transmission rate is 12 Mbit/s. The module supports automatic baud rate detection, allowing it to identify the transmission rate used by the connected PROFIBUS network. The selected rate must be supported by the network devices and installation.
Cyclic communication handles the regular exchange of process data between the DP Master and configured slave devices. It is used for normal machine operation, including reading sensor values and updating output states. Acyclic communication through DPV1 is used to access additional device information, parameters, and diagnostic records. Both communication methods can be used within the supported PROFIBUS DP configuration.