The 6AG2155-6AU01-1CN0 is a SIPLUS ET 200SP high-functionality interface module designed to connect distributed I/O stations to an industrial PROFINET network. It is intended for automation systems that require reliable communication between a central controller and peripheral modules installed near machinery, infrastructure equipment, or remote process areas.
The module is based on the standard 6ES7155-6AU01-0CN0 design and belongs to the SIPLUS extreme RAIL interface-module family. It features conformal coating and an environmental specification intended for demanding railway-related installations.
This model provides a high-functionality interface for the ET 200SP distributed I/O system. Its principal capabilities include support for up to 64 ET 200SP I/O modules, connection of up to 16 ET 200AL modules in supported configurations, S2 system redundancy, multi-module hot swapping, and isochronous operation with a supported cycle time of 0.25 ms.
The interface module acts as the communication link between the PROFINET controller and the distributed I/O station. It does not replace the PLC CPU or the individual I/O modules. Instead, it coordinates station communication and allows the controller to exchange process data with the installed peripheral modules.
The product is particularly relevant to railway equipment, industrial infrastructure, and automation installations where environmental resistance, network availability, and flexible I/O expansion are important design considerations.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Product model | 6AG2155-6AU01-1CN0 |
| Product series | SIPLUS ET 200SP |
| Product family | SIPLUS extreme RAIL interface modules |
| Product designation | IM 155-6 PN HF T1 RAIL |
| Product type | High-functionality distributed I/O interface module |
| Standard base model | 6ES7155-6AU01-0CN0 |
| Communication protocol | PROFINET IO |
| PROFINET interface | Two-port interface; one slot for a BusAdapter |
| Maximum ET 200SP I/O modules | 64, subject to supported configuration |
| Maximum ET 200AL modules | 16, subject to supported configuration |
| Redundancy | S2 system redundancy supported |
| Hot-swapping capability | Multi-module hot swapping, under supported operating conditions |
| Isochronous mode | Supported |
| Specified isochronous cycle time | 0.25 ms |
| Rated supply voltage | 24 V DC |
| Permissible supply voltage | 19.2–28.8 V DC |
| Environmental protection | Conformal coating |
| Standard operating temperature range | -25°C to +60°C |
| Short-duration high-temperature condition | Up to +70°C for 10 minutes under applicable conditions |
| Protection rating | IP20 |
| Dimensions (W × H × D) | 50 × 117 × 74 mm |
| Approximate net weight | 0.170 kg |
| Included component | Server module |
| Typical application | Railway automation, distributed industrial I/O, high-availability PROFINET systems |
The stated dimensions refer to the interface module’s physical envelope. The approximate 0.170 kg weight is the listed product net weight for the order configuration; the interface module itself is approximately 0.120 kg without a BusAdapter. The exact supplied accessories should be confirmed when planning installation or calculating shipping weight.
The following table summarizes the main electrical, communication, environmental, and mechanical characteristics of the 6AG2155-6AU01-1CN0.
| Parameter | Detailed specification |
|---|---|
| Model number | 6AG2155-6AU01-1CN0 |
| Module designation | IM 155-6 PN HF T1 RAIL |
| System family | SIPLUS ET 200SP |
| Functional category | PROFINET distributed I/O interface |
| Standard base model | 6ES7155-6AU01-0CN0 |
| Rated supply voltage | 24 V DC |
| Permissible supply voltage | 19.2–28.8 V DC |
| Power supply type | DC |
| PROFINET interface | Two-port interface with one BusAdapter slot |
| BusAdapter | Selected according to the required physical network connection |
| Communication protocol | PROFINET IO |
| Redundancy function | S2 system redundancy supported |
| Maximum ET 200SP modules | Up to 64, subject to the system configuration |
| Maximum ET 200AL modules | Up to 16, with supported configuration |
| Hot-swapping function | Multi-module hot swapping, subject to system requirements |
| Isochronous operation | Supported |
| Specified isochronous cycle | 0.25 ms |
| Conformal coating | Yes |
| Operating temperature | -25°C to +60°C |
| Short-duration high-temperature rating | +70°C for 10 minutes under specified conditions |
| Protection rating | IP20 |
| Mounting arrangement | Compatible ET 200SP station on a DIN rail |
| Server module | Included |
| Optional network strain relief | Supported accessory, depending on configuration |
| Dimensions (W × H × D) | 50 × 117 × 74 mm |
| Dimensions in centimetres | 5.0 × 11.7 × 7.4 cm |
| Approximate weight without BusAdapter | 0.120 kg |
| Approximate listed net weight | 0.170 kg |
| Main function | Communication between the PROFINET controller and distributed I/O |
| Typical engineering environment | STEP 7 / TIA Portal, with a compatible software version |
| Typical installation | Industrial control cabinet or suitable railway equipment enclosure |
The module’s precise electrical consumption, diagnostic behavior, address limits, and supported network functions should be checked against the complete hardware specification for the intended installation. These values may depend on firmware, the selected BusAdapter, the controller, and the station configuration.
In a distributed automation system, a PLC does not need to be physically located beside every sensor and actuator. Instead, the controller can exchange process data with remote I/O stations over an industrial network.
The 6AG2155-6AU01-1CN0 provides the interface for an ET 200SP station connected to PROFINET. It manages communication between the controller and the installed peripheral modules so that the PLC program can read field inputs and update output values.
For example, a machine may have sensors at several workstations and actuators distributed along a production line. A remote ET 200SP station can collect the local signals and transfer their data to the PLC. The PLC processes the information and sends updated commands back through the same automation architecture.
This arrangement can reduce the amount of field wiring routed to a central cabinet and make it easier to organize I/O by machine section or process area.
The HF designation identifies this as a high-functionality interface module. Compared with more basic interface variants, the model supports advanced system capabilities such as S2 redundancy, multi-module hot swapping, and isochronous operation.
These capabilities are relevant when the automation system has demanding communication, synchronization, or maintenance requirements.
S2 redundancy can help a suitably designed system maintain communication through a supported redundant controller arrangement. Multi-module hot swapping can simplify maintenance in compatible configurations. Isochronous operation can help coordinate time-sensitive processes where the controller, network, and connected devices support the required synchronization.
These features must be configured as part of the complete automation system. Their presence in the interface module alone does not guarantee redundancy, uninterrupted operation, or deterministic performance in an incorrectly configured installation.
The SIPLUS RAIL version is intended for more demanding environmental conditions than many standard automation modules.
Its conformal coating provides additional protection for electronic assemblies against specified environmental influences. The model has a stated operating range of -25°C to +60°C and permits +70°C for 10 minutes under the applicable conditions.
This makes the module a candidate for railway-related equipment and other industrial installations where temperature variation and environmental stresses need to be considered during equipment selection.
It is still necessary to use an appropriate enclosure and comply with the specified installation conditions. The module’s IP20 rating does not permit direct exposure to water or unrestricted exposure to dust.
Railway installations may require distributed monitoring and control across equipment cabinets, auxiliary systems, and infrastructure installations.
The module can serve as the PROFINET interface for a compatible ET 200SP station used to collect equipment-status signals and exchange control data with a central automation controller.
Potential applications include auxiliary equipment monitoring, ventilation control, service systems, and suitable railway infrastructure automation.
The final application must satisfy the relevant railway qualification, safety, and installation requirements. The module should not be assumed to be a safety-certified controller simply because it belongs to a railway-oriented product family.
Some industrial applications place a high value on keeping communication available during certain controller or system faults.
In a properly engineered S2 redundant PROFINET system, the interface module can participate in a supported redundant-controller architecture. This can reduce the risk of losing process communication following a supported redundancy event.
Possible applications include infrastructure monitoring, selected process-control installations, and equipment where a communication interruption could cause significant operational disruption.
The complete system must use compatible controllers, network equipment, engineering configuration, and supported redundancy functions.
The module supports up to 64 ET 200SP I/O modules and up to 16 ET 200AL modules in supported configurations.
This allows a station to accommodate a relatively large range of field signals without requiring every I/O point to be wired directly to a central PLC cabinet.
Applications may include large machines, multi-section production lines, industrial utility systems, and equipment with many sensors and actuators distributed across a physical area.
The actual number of modules that can be used depends on the station configuration, electrical requirements, controller limits, and the specifications of the connected modules.
Isochronous operation can be useful when the control application requires synchronized data exchange at precisely defined intervals.
The specified 0.25 ms cycle capability makes the module relevant to suitable time-sensitive applications where the controller, network configuration, and connected devices support the required operating mode.
Examples may include synchronized machinery and coordinated automation processes. Actual achievable system performance depends on the full network and controller configuration, not on the interface module alone.
Distributed I/O is widely used in manufacturing equipment where sensors and actuators are spread across production stations.
The module can connect an ET 200SP station that handles local digital and analog signals to the central controller. The PLC can then use these signals to coordinate conveyors, pneumatic equipment, drives, machine interlocks, and other production functions.
The modular structure is useful when a machine needs to combine multiple types of I/O and may need to be expanded or maintained over time.
Infrastructure installations may place control equipment in remote cabinets, equipment rooms, tunnels, or other locations where environmental conditions are more demanding than in a conventional office environment.
A distributed I/O station can collect local signals and communicate with the controller over PROFINET. The SIPLUS RAIL interface module can be considered when its environmental ratings and communication capabilities match the installation requirements.
The enclosure, cable routing, power supply, and grounding arrangement remain essential parts of a reliable design.
The module provides a PROFINET interface for a distributed I/O station and supports high-functionality features such as S2 redundancy and isochronous operation.
These capabilities make it suitable for systems that require more than basic remote I/O communication, provided that the associated controller and network components support the intended functions.
The ability to support up to 64 ET 200SP modules and up to 16 ET 200AL modules in supported configurations provides flexibility when designing larger distributed I/O stations.
This can reduce the need to divide a large group of field signals into multiple smaller stations, depending on the layout, network architecture, and system limits.
The supported multi-module hot-swapping function can help maintenance personnel replace eligible modules without shutting down the entire station, when the system has been configured for this operation.
This may reduce maintenance interruptions in suitable installations.
Hot swapping must be performed according to the approved system procedure. Not every module, configuration, or operating condition supports unrestricted replacement while powered.
The conformal coating and specified SIPLUS RAIL temperature range make the product relevant to demanding environmental applications.
These features can be beneficial in railway-related systems and industrial cabinets exposed to environmental stresses.
They do not eliminate the need for proper enclosure protection, environmental assessment, or compliance with the relevant application standards.
The module supports isochronous operation with a specified 0.25 ms cycle capability.
This can be valuable when synchronized data exchange is required by a supported motion-control or time-sensitive automation application.
The final cycle time and synchronization performance depend on the complete system design, including the controller, network configuration, and connected devices.
The ET 200SP platform supports different I/O modules within one distributed station. Engineers can select the digital, analog, or other supported functions required by the machine or process.
This modular design can make maintenance and expansion easier because the station can be organized around the required I/O functions rather than a fixed, all-in-one I/O arrangement.
The module measures approximately 50 × 117 × 74 mm, allowing it to fit into many compact industrial control cabinets.
Its listed net weight is approximately 0.170 kg for the relevant order configuration. The interface module itself weighs approximately 0.120 kg without a BusAdapter.
When planning the cabinet, allow enough space for adjacent modules, wiring, cable bend radius, connector access, heat dissipation, and maintenance work.
Power supply: Use a suitable 24 V DC supply and verify that the voltage remains within the specified 19.2–28.8 V DC range under the expected load.
Controller compatibility: Confirm that the PLC model, firmware, and engineering software support the selected interface module and the intended high-functionality features.
BusAdapter selection: Select a compatible BusAdapter that matches the required physical network connection and cabling arrangement.
PROFINET configuration: Configure the device name, IP settings, network topology, and controller relationship according to the engineering design.
Redundancy configuration: If S2 redundancy is required, confirm compatibility with the controller and network architecture and verify the configuration during commissioning.
Station configuration: Ensure that the number and types of ET 200SP and ET 200AL modules are supported by the interface module and the selected station arrangement.
Environmental limits: Observe the specified temperature range and the +70°C short-duration condition. Do not assume that +70°C is a continuous operating temperature.
Cabinet protection: The IP20 rating means the module needs an appropriate enclosure where protection from water, dust, or accidental contact is required.
Maintenance: Follow the approved procedures for multi-module hot swapping and verify which modules can be replaced under the actual operating conditions.
The following models are related to the SIPLUS ET 200SP interface family or to the standard ET 200SP platform. They are options to evaluate for new designs, extensions, or replacement projects; they are not automatically interchangeable.
| Model | Product description | Key parameters | Dimensions (W × H × D) | Weight (kg) |
|---|---|---|---|---|
| 6AG2155-6AU01-1CN0 | SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL | PROFINET; S2 redundancy; multi-module hot swapping; 0.25 ms isochronous capability; up to 64 ET 200SP modules and 16 ET 200AL modules in supported configurations | 50 × 117 × 74 mm | 0.170 |
| 6ES7155-6AU01-0CN0 | Standard ET 200SP IM 155-6 PN HF | Standard-base high-functionality interface; PROFINET; S2 redundancy; multi-module hot swapping; isochronous operation | 50 × 117 × 74 mm | Approx. 0.147 |
| 6AG2155-6AU00-1CN0 | SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL variant | Railway-oriented SIPLUS interface; PROFINET; conformal coating; high-functionality distributed I/O | 50 × 117 × 74 mm | Approx. 0.147 |
| 6AG2155-6AU01-4BN0 | SIPLUS ET 200SP IM 155-6 PN ST RAIL variant | PROFINET distributed I/O interface; environmental protection for demanding installations; verify exact base model and functionality before replacement | 50 × 117 × 74 mm | Approx. 0.147 |
| 6AG2155-6AA01-4BN0 | SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL | PROFINET interface; supplied two-port RJ45 BusAdapter arrangement; distributed I/O station; single-module hot swapping | 50 × 117 × 74 mm | 0.190 |
Dimensions and weights for related models are reference values and may vary by supplied accessories and product revision. In particular, interface variants differ in supported I/O capacity, redundancy, hot-swapping functions, synchronization, and environmental limits.
– 6AG2155-6AU01-1CN0: Consider this model when the application needs high-functionality PROFINET communication, S2 redundancy, multi-module hot swapping, and isochronous operation in the specified SIPLUS RAIL environment.
– 6ES7155-6AU01-0CN0: Consider the standard version when its environmental ratings are sufficient and the standard product configuration meets the installation requirements.
– 6AG2155-6AU00-1CN0: Evaluate this related SIPLUS RAIL variant when its specific interface and station functions meet the application requirements.
– 6AG2155-6AU01-4BN0: Confirm the exact order code and technical characteristics before treating this as a substitute. Similar model numbers do not guarantee equivalent hardware or functions.
– 6AG2155-6AA01-4BN0: Consider this ST interface variant when its station capacity and supported maintenance functions are sufficient and the supplied two-port BusAdapter arrangement is appropriate.
For a replacement project, compare the complete part number, hardware revision, BusAdapter, supported peripheral modules, firmware requirements, and redundancy configuration before purchasing.
These products cover common PLC controller and distributed I/O functions that may be used alongside a PROFINET interface module in a larger automation system.
| Model | Product description | Key parameters | Dimensions (W × H × D) | Weight (kg) |
|---|---|---|---|---|
| 6ES7511-1AK02-0AB0 | SIMATIC S7-1500 CPU 1511-1 PN | Compact PLC CPU; PROFINET interface; suitable for general machine and process automation | Approx. 35 × 147 × 129 mm | Approx. 0.390 |
| 6ES7512-1DK01-0AB0 | SIMATIC ET 200SP CPU 1512SP-1 PN | Distributed controller with PROFINET communication; compact ET 200SP form factor | Approx. 50 × 117 × 74 mm, CPU dimensions vary by assembly | Verify exact assembly |
| 6ES7155-6AU01-0CN0 | SIMATIC ET 200SP IM 155-6 PN HF | High-functionality PROFINET interface; supports advanced station features, subject to configuration | 50 × 117 × 74 mm | Approx. 0.147 |
| 6ES7131-6BH01-0BA0 | SIMATIC ET 200SP digital input module | Digital input expansion for compatible discrete field signals; check exact channel and electrical ratings | Approx. 15 × 73 × 58 mm | Approx. 0.030 |
| 6ES7132-6BH01-0BA0 | SIMATIC ET 200SP digital output module | Digital output expansion for compatible discrete loads; verify output type and rated current | Approx. 15 × 73 × 58 mm | Approx. 0.030 |
The table gives indicative specifications for comparison. Verify the exact product revision, accessories, and assembly dimensions before using these values for procurement, enclosure design, or shipping calculations.
A typical distributed automation system combines a PLC CPU, a PROFINET interface module, and the I/O modules needed for the application.
The CPU executes the control program and determines the required machine behavior. The interface module manages communication between the controller and the remote station. Digital input modules receive signals from switches and sensors, while digital output modules control compatible loads such as relays, solenoids, and indicator devices.
In a more complex installation, analog I/O modules can be added to measure process values or issue variable control commands. The selected module combination depends on the required signal types, number of I/O points, controller capability, communication architecture, and environmental conditions.
The 6AG2155-6AU01-1CN0 is most useful when the distributed station needs the advanced interface functions and environmental characteristics of the SIPLUS RAIL version.
The 6AG2155-6AU01-1CN0 is a high-functionality SIPLUS ET 200SP PROFINET interface module designed for distributed automation systems in demanding environments.
Its principal capabilities include support for up to 64 ET 200SP modules and 16 ET 200AL modules in supported configurations, S2 redundancy, multi-module hot swapping, and isochronous operation with a specified 0.25 ms cycle capability. It uses a 24 V DC supply, has a stated operating temperature range of -25°C to +60°C, and permits +70°C for 10 minutes under applicable conditions.
The module measures approximately 50 × 117 × 74 mm. Its listed net weight is approximately 0.170 kg for the relevant order configuration, while the interface module without a BusAdapter weighs approximately 0.120 kg.
The product is particularly relevant to railway-related automation, high-availability distributed I/O, and industrial systems that require advanced PROFINET functionality. Its suitability for any specific application depends on the controller, network, station configuration, environmental conditions, and relevant qualification requirements.
Before purchasing or replacing this module, confirm the exact order code, supported hardware revision, BusAdapter arrangement, firmware compatibility, and the required redundancy and hot-swapping functions.