Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider TM3TI4 is an analog input module in the Modicon TM3 expansion family, used to acquire temperature-related signals in compatible PLC control systems. It extends the controller’s ability to monitor process conditions, allowing temperature measurements to become part of an automated machine’s monitoring, sequencing, and control logic.
In applications such as industrial ovens, packaging machinery, environmental chambers, and process equipment, temperature feedback helps the controller determine whether a process is operating within its intended range. The module receives supported sensor signals and makes the resulting input information available to the controller for processing. The PLC program can then use these values for temperature monitoring, alarms, sequence transitions, or coordination with other control devices.
When selecting or replacing the TM3TI4, engineers should confirm the supported sensor types, input channel configuration, measurement range, resolution, and wiring arrangement in Schneider Electric’s official documentation. These details determine whether the module is suitable for the installed temperature sensors and the requirements of the application.
| Parameter | Description |
|---|---|
| Brand | Schneider Electric |
| Model | TM3TI4 |
| Product Series | Modicon TM3 |
| Product Type | Analog Input Module |
| Product Family | Modicon TM3 Expansion Modules |
| Primary Function | Temperature-related analog signal acquisition |
| System Role | PLC temperature input interface |
| Input Signal Type | Temperature sensor signals supported by the module |
| Input Channels | 4 temperature input channels |
| Supported Sensor Types | Verify the supported thermocouple and temperature sensor types in the official datasheet |
| Measurement Range | Depends on the selected sensor type; refer to the manufacturer’s specifications |
| Measurement Resolution | Refer to the official technical documentation |
| Conversion and Update Time | Refer to the model-specific specifications |
| Controller Compatibility | Verify using the Modicon TM3 compatibility documentation |
| Mounting | Follow the manufacturer’s installation instructions |
| Wiring | Use the model-specific sensor wiring diagram |
| Dimensions | 90 × 70 × 23.6 mm |
| Weight | 0.11 kg |
The TM3TI4 acquires signals from supported temperature sensors and supplies measurement information to the PLC through the Modicon TM3 expansion system. The controller uses this information as part of its application logic.
During operation, a connected temperature sensor responds to changes in the monitored process. The module processes the sensor signal according to its supported input type and measurement characteristics, then makes the resulting temperature data available to the controller. The PLC program can compare the measured value with configured limits, evaluate process conditions, and issue control commands through the appropriate output modules.
For example, in an industrial heating process, the controller may monitor temperatures at several points in a chamber. When a measured value reaches a configured threshold, the program can advance a process step, activate an alarm, or adjust the associated control output. The actual response depends on the application program and the equipment connected to the controller.
Accurate operation depends on selecting a supported sensor, using the correct wiring arrangement, configuring the corresponding input type, and applying suitable measurement limits. Sensor faults, incorrect wiring, or an unsuitable input configuration can cause invalid or unexpected readings.
| System Component | Role in the Control Architecture |
|---|---|
| Modicon Logic Controller | Executes the control program and processes temperature measurements |
| TM3 Expansion Connection | Transfers input data between the module and the compatible controller |
| TM3TI4 Analog Input Module | Acquires supported temperature sensor signals for PLC processing |
| Temperature Sensors | Measure temperature at selected machine or process locations |
| Digital Input Modules | Provide discrete feedback such as equipment status and limit-switch signals |
| Digital Output Modules | Execute discrete commands generated by the controller program |
| Analog Output Modules | Provide analog command signals where required by the process |
| Heating or Cooling Equipment | Changes process temperature in response to the relevant control system |
| Programming and Diagnostic Tools | Support input configuration, monitoring, and troubleshooting |
| Application | Typical Use |
|---|---|
| Industrial Ovens | Monitors temperature at selected points during heating and curing processes |
| Packaging Machinery | Tracks temperature in sealing, forming, or other temperature-sensitive machine stages |
| Environmental Chambers | Supplies temperature measurements for environmental testing and control sequences |
| Plastics Processing | Monitors temperature conditions in selected heating zones, subject to sensor compatibility |
| Food and Beverage Equipment | Provides temperature feedback for process monitoring where the installed sensor type is supported |
| Process Skids | Acquires temperature measurements for packaged industrial process systems |
| Laboratory and Test Equipment | Monitors multiple temperature points during automated test cycles |
| General Machine Automation | Adds temperature feedback to PLC applications that require measurement-based decisions |
| Component | Function in the System |
|---|---|
| Compatible Modicon Logic Controller | Processes acquired temperature data and executes the control program |
| Modicon TM3 Digital Input Modules | Receive discrete equipment-status and sensor signals |
| Modicon TM3 Digital Output Modules | Execute discrete control commands from the PLC |
| Modicon TM3 Analog Output Modules | Provide analog control signals where required |
| Supported Temperature Sensors | Supply the temperature signals accepted by the module |
| Sensor Wiring and Terminal Accessories | Provide the required electrical connections between sensors and the module |
| Heating and Cooling Equipment | Regulates process temperature through the wider control system |
| Control Power Supply | Supplies the relevant control-system circuits |
| Programming and Diagnostic Tools | Support configuration, monitoring, and troubleshooting |
| Model or Product Family | Product Type | Relationship |
|---|---|---|
| Schneider Modicon TM3 Analog Input Modules | Analog Input Modules | Provide alternative analog input configurations; confirm signal compatibility before selection |
| Schneider Modicon TM3 Digital Input Modules | Discrete Input Modules | Add discrete feedback from switches and sensors |
| Schneider Modicon TM3 Digital Output Modules | Discrete Output Modules | Add discrete output capability for machine control |
| Schneider Modicon TM3 Analog Output Modules | Analog Output Modules | Provide analog command signals for compatible applications |
| Schneider Modicon TM3 Communication Modules | Communication Expansion Modules | Address supported communication requirements within the system configuration |
| Schneider Modicon Logic Controllers | Programmable Logic Controllers | Process input data and coordinate the overall automation sequence |
The TM3TI4 is a Modicon TM3 analog input module intended for temperature-related signal acquisition. It supplies measurement information from supported temperature sensors to a compatible PLC for monitoring and control logic. Confirm the exact supported sensor types in the official datasheet.
The permitted sensor types and measurement ranges must be checked in Schneider Electric’s official TM3TI4 documentation. Before connecting a sensor, verify its type, wiring requirements, measurement range, and the channel configuration supported by the module.
Potential causes include a damaged sensor, incorrect wiring or polarity, a loose terminal, electrical interference, an unsuitable sensor configuration, or a measurement value outside the supported range. Check the sensor and wiring first, then review the channel configuration and controller diagnostics.
Not automatically. Different analog input modules may support different signal types, sensor configurations, measurement ranges, and channel arrangements. Compare the official specifications and verify controller compatibility before selecting a replacement.