• GE UR 9GH Multilin UR Series Universal Relay CPU Module
  • GE UR 9GH Multilin UR Series Universal Relay CPU Module
  • GE UR 9GH Multilin UR Series Universal Relay CPU Module
  • GE UR 9GH Multilin UR Series Universal Relay CPU Module
Product Overview The GE UR 9GH is a Universal Relay CPU Module for the Multilin UR Series modular protection platform. It serves as the central processing element that coordinates measurement data, prot……
GE UR 9GH Multilin UR Series Universal Relay CPU Module
  • GE
  • UR 9GH
  • Universal Relay CPU Module
  • USA
  • 120 × 30 × 100 mm
  • 0.8 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

GE UR 9GH Multilin UR Series Universal Relay CPU Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE UR 9GH Multilin UR Series Universal Relay CPU Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE UR 9GH Multilin UR Series Universal Relay CPU Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE UR 9GH Multilin UR Series Universal Relay CPU Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE UR 9GH is a Universal Relay CPU Module for the Multilin UR Series modular protection platform. It serves as the central processing element that coordinates measurement data, protection functions, control logic, diagnostics, and communication tasks within a configured UR relay.

In a typical protection cabinet, the CPU module works together with CT/VT input modules, digital and analog I/O, communication interfaces, and other functional modules. Measurement signals collected from field-side interfaces are passed into the relay architecture, where the CPU processes the available information according to the configured protection and control scheme.

The UR 9GH is relevant to applications where modular relay architecture is used for generator, motor, transformer, feeder, or other electrical equipment protection. During maintenance, CPU module compatibility is particularly important because the processor participates in the overall relay configuration and coordination of installed functional modules.


Technical Specifications

Parameter Specification
Product Model UR 9GH
Product Type Universal Relay CPU Module
Product Family Multilin UR
Series Multilin UR Series
Module Type CPU Module
System Role Central processing and relay coordination
Protection Platform Universal Relay
Processing Function Measurement, protection, control, and diagnostic processing
I/O Integration Modular UR Series I/O architecture
Communication Role Relay system communication and data coordination
Configuration UR Series relay configuration
Application Electrical protection and control
Installation Modular relay chassis
Dimensions 120 × 30 × 100 mm
Weight 0.8 kg

Product Features

  • Central processing module for a Multilin UR Series relay configuration.
  • Coordinates information received from measurement and I/O modules.
  • Supports execution of configured protection and control functions.
  • Integrates relay diagnostics and system status information into the processing architecture.
  • Works with the modular structure of the UR Series rather than functioning as an isolated protection device.
  • Suitable for protection systems requiring coordinated processing of electrical measurements, status signals, and control commands.
  • Useful for maintenance and replacement of the CPU section in an existing UR Series relay installation.
  • Supports system-level coordination between the relay processor and installed functional modules.

Working Principle

1. Measurement and status acquisition

Field measurements and status information enter the UR relay through the appropriate CT/VT, digital input, analog input, and other interface modules. These modules form the measurement and signal acquisition layer, while the UR 9GH handles the processing side of the relay architecture.

2. Central processing

The CPU receives available measurement and status information from the modular relay system and processes it according to the configured protection and control functions. The processor therefore provides the link between incoming electrical information and the logical decisions performed by the relay.

3. Protection and control coordination

Once measurement conditions and equipment status are evaluated, the configured relay logic can determine the required protection or control response. The CPU coordinates this processing with the other functional modules installed in the UR relay.

4. Diagnostics and system status

The processor also participates in monitoring the operating condition of the relay system. Diagnostic information can help maintenance personnel distinguish between a field measurement problem, an I/O issue, a configuration problem, communication interruption, or a processor-related fault.

5. Communication and system integration

In an integrated protection system, processed information may be exchanged with other devices or supervisory systems through the relay’s communication architecture. The CPU provides the processing foundation needed to coordinate these system-level data and control functions.


Role in a Multilin UR Series Protection Control Architecture

The UR 9GH sits at the processing center of the modular relay architecture. CT/VT modules provide electrical measurement interfaces, I/O modules handle field signals, communication modules connect the relay to external systems, and the CPU coordinates the information exchanged between these functional sections.

Architecture Layer Typical Function Relationship with UR 9GH
CT/VT Interface Receives electrical measurement signals Supplies measurement information for processing
Digital I/O Handles status and control signals Provides field status and receives coordinated control functions
Analog I/O Handles applicable analog process signals Supplies additional operating information
Communication Interface Connects relay with external systems Exchanges processed relay data and system information
CPU Module Central processing and coordination UR 9GH performs the core processing role
Protection Logic Executes configured protection functions Processed and coordinated by the CPU
Supervisory System Monitoring and higher-level control Receives relevant relay information through communication architecture

Industrial Applications

Application Use of the UR 9GH
Generator Protection Coordinates processing of generator measurement and protection information within the UR relay
Motor Protection Supports processing and coordination of motor protection functions
Transformer Protection Provides central processing for a modular transformer protection configuration
Feeder Protection Processes measurement and status information used by feeder protection logic
Substation Protection Integrates relay processing with field I/O and communication architecture
Electrical Distribution Supports coordinated protection and monitoring of distribution equipment
Industrial Power Systems Provides central relay processing for plant electrical protection systems
Retrofit Projects Can be used when maintaining or servicing compatible modular UR Series protection equipment

Installation and Maintenance

  1. Isolate the relay before servicing — Follow the site’s electrical safety procedure and isolate the relevant equipment before removing or installing the CPU module.
  2. Verify module compatibility — Confirm that the replacement CPU is appropriate for the existing UR Series relay configuration before installation.
  3. Check the relay configuration — Record relevant configuration information before replacing a processor so the installed protection scheme can be restored correctly.
  4. Use ESD protection — Handle the CPU using appropriate electrostatic discharge precautions to reduce the risk of damage to electronic circuitry.
  5. Inspect the module and chassis — Check the connector area, module seating points, and chassis interface for visible contamination or mechanical damage.
  6. Install the module correctly — Align the CPU with the intended chassis position and ensure that it is fully seated without excessive mechanical force.
  7. Check neighboring modules — Confirm that adjacent CT/VT, I/O, communication, and other functional modules remain properly seated after CPU installation.
  8. Restore configuration carefully — If configuration data must be restored, verify that the correct relay configuration is loaded for the particular protection application.
  9. Check system diagnostics — Review available diagnostic information after startup and investigate any module, communication, or configuration alarms.
  10. Verify communication — Confirm communication with connected supervisory, engineering, or substation systems where applicable.
  11. Perform functional testing — Test the relevant protection, control, I/O, and alarm functions according to the site’s commissioning or maintenance procedure.
  12. Document the replacement — Record the installed CPU model, configuration status, test results, and maintenance date for future troubleshooting and service work.

Related Components

Component Function
GE Multilin UR CT/VT Modules Provide current and voltage measurement interfaces for the relay
GE Multilin UR Digital I/O Modules Interface relay logic with field status and control circuits
GE Multilin UR Analog I/O Modules Provide applicable analog signal interfaces
GE Multilin UR Communication Modules Connect the relay with external communication and supervisory systems
GE Multilin UR Relay Chassis Provides the modular mechanical and electrical platform
GE Multilin UR Protection Modules Support application-specific protection functions
Field CTs and VTs Provide electrical measurement signals to the relay
Relay Configuration Software Used for configuration, settings, diagnostics, and maintenance activities

Recommended Related Models

Model Product Type Typical Relationship
GE UR 9AH Universal Relay CPU Module CPU module for Multilin UR Series relay architectures
GE UR 9CH Universal Relay CPU Module Alternative UR Series CPU configuration
GE UR 9EH Universal Relay CPU Module UR Series central processing module
GE UR 9EV Universal Relay CPU Module Related UR Series CPU module
GE UR 8GH CT/VT Ground Protection Module Measurement interface for ground protection applications
GE UR 8LH CT/VT Module CT/VT measurement interface
GE UR 8NH CT/VT Module CT/VT measurement interface for modular relay systems

Key Advantages

  • Centralizes processing within the modular UR Series relay architecture.
  • Coordinates measurement, protection, control, diagnostics, and communication functions.
  • Integrates naturally with the UR Series modular I/O structure.
  • Supports maintenance and replacement of the CPU section without changing the complete protection architecture.
  • Suitable for complex electrical protection systems requiring coordinated processing.
  • Helps establish a clear processing path between field measurement modules and relay protection logic.

Technical FAQs

What is the role of the GE UR 9GH in a Multilin UR relay?

The UR 9GH functions as the CPU section of the relay. It processes information supplied by the installed measurement and I/O modules and coordinates configured protection, control, diagnostic, and communication functions.

Can the UR 9GH be treated as a standalone protection relay?

No. The CPU is one functional part of the modular UR Series architecture. The complete protection system also depends on the installed measurement interfaces, I/O, communication functions, configuration, and application-specific relay modules.

What should be checked when replacing a UR 9GH CPU module?

The replacement should be checked for compatibility with the existing relay configuration and installed modules. Configuration data, module status, diagnostics, communication functions, and applicable protection logic should also be verified after installation.

What symptoms can indicate a CPU-related problem in a UR Series relay?

Possible indications include processor or system diagnostic alarms, abnormal relay initialization, loss of expected system coordination, communication-related problems, or unexpected behavior in configured relay functions. Troubleshooting should also examine power, configuration, neighboring modules, communication paths, and field interfaces before identifying the CPU as the cause.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501