• Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module
  • Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module
  • Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module
  • Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module
Product Overview The Allen-Bradley 2080-TC2 is a two-channel non-isolated thermocouple input plug-in module designed for the Micro800 programmable controller family. It enables temperature measurement b……
Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module
  • Allen Bradley
  • 2080-TC2
  • Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module
  • USA
  • 62 x 20 x 31.5 mm
  • 0.021 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Plug-In Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen-Bradley 2080-TC2 is a two-channel non-isolated thermocouple input plug-in module designed for the Micro800 programmable controller family. It enables temperature measurement by receiving signals from compatible thermocouple sensors and converting them into digital temperature data for the controller.

The module supports eight thermocouple types: J, K, N, T, E, R, S, and B. Each input channel can be configured independently through Rockwell Automation’s Connected Components Workbench (CCW) software, allowing engineers to select the appropriate sensor type and input filter settings for the application.

The 2080-TC2 also includes cold-junction compensation (CJC) support through an external NTC thermistor supplied with the module. This compensation is important for accurate thermocouple measurements because the reference junction temperature must be considered when interpreting the sensor signal.

As a compact plug-in component, the 2080-TC2 can be installed in a compatible Micro800 controller without requiring a separate remote I/O rack. It is suitable for temperature monitoring and process control applications where a small number of thermocouple measurement points are required.

Technical Specifications

Parameter Specification
Brand Allen-Bradley
Model 2080-TC2
Product Family Micro800
Product Type Thermocouple Input Plug-In Module
Number of Channels 2
Input Type Thermocouple
Channel Isolation Non-isolated
Supported Thermocouple Types J, K, N, T, E, R, S, B
Analog Input Resolution 14 bit
Input Accuracy ±1.0°C at 25°C
Cold-Junction Compensation Error ±1.2°C at 25°C
Cold-Junction Compensation External NTC thermistor
Input Impedance Greater than 300 kΩ
Common-Mode Rejection Ratio 100 dB at 50/60 Hz
Normal-Mode Rejection Ratio 70 dB at 50/60 Hz
Open-Circuit Detection Time 8–1515 ms
Input Configuration Connected Components Workbench software
Power Consumption 40 mA at 3.3V DC
Operating Temperature -20–65°C
Storage Temperature -40–85°C
Mounting Micro800 controller plug-in slot
Dimensions 62 × 20 × 31.5 mm
Weight 0.021 kg

The accuracy figures are specified at 25°C. Actual measurement performance depends on sensor type, installation conditions, wiring, and cold-junction compensation.

Operating Principle and Main Functions

1. Two-Channel Temperature Measurement

The 2080-TC2 provides two independent thermocouple input channels. Each channel receives a low-level voltage signal generated by a thermocouple sensor in response to temperature differences.

The module converts these analog signals into digital temperature information that can be used by the Micro800 controller program.

This arrangement allows one controller to monitor two temperature points, such as separate heating zones, process vessels, or machine components.

2. Support for Eight Thermocouple Types

The module supports the following thermocouple types:

  • Type J
  • Type K
  • Type N
  • Type T
  • Type E
  • Type R
  • Type S
  • Type B

Each channel can be configured for its connected thermocouple type. Selecting the correct sensor type is essential because different thermocouples have different temperature-to-voltage characteristics.

3. Cold-Junction Compensation

Thermocouples measure temperature based on the voltage generated between two dissimilar metal conductors. Accurate measurement therefore requires compensation for the temperature at the reference junction.

The 2080-TC2 uses an external NTC thermistor for cold-junction compensation. The thermistor is supplied with the module and must be connected to terminals A3 and B3 according to the installation instructions.

The CJC arrangement is common to both thermocouple channels. Correct installation of the thermistor is important for reliable temperature measurement.

4. Digital Signal Conversion

The module provides 14-bit analog input resolution. It converts the thermocouple signals into digital values that the Micro800 controller can process.

The resulting temperature information can be used in monitoring logic, alarm conditions, sequencing, and PID-based temperature control applications.

5. Input Filtering and Fault Detection

Each channel supports configurable input filtering. Filter settings can help reduce the influence of unwanted electrical noise on temperature measurements.

The module also provides open-circuit, overrange, and underrange detection. These diagnostic functions help the controller identify abnormal sensor conditions and support troubleshooting.

Industrial Applications

Industrial Heating Systems

The 2080-TC2 can monitor temperatures in industrial ovens, heating equipment, furnaces, and thermal processing machinery. Temperature values can be used by the controller to manage heating sequences and generate alarms.

Plastic Processing Equipment

Extrusion machines and plastic molding equipment often require temperature monitoring across several heating zones. The two input channels can monitor selected zones within a Micro800-based control system.

Food and Beverage Processing

Temperature monitoring is important in heating, cooling, and production processes. Compatible thermocouples connected to the 2080-TC2 can provide temperature data for process monitoring and control.

Packaging Machinery

Packaging equipment may include sealing heaters, heated rollers, and temperature-controlled components. The module can monitor these points and provide feedback to the controller.

Laboratory and Test Equipment

Small industrial testing systems may require temperature measurements at multiple locations. The 2080-TC2 offers a compact solution for acquiring thermocouple signals through a Micro800 controller.

General Process Automation

The module can be incorporated into compact process control systems where temperature is an important operating variable, including equipment monitoring, thermal regulation, and automated production processes.

Installation and System Integration

Correct installation and configuration are important for obtaining reliable temperature readings.

1. Controller Compatibility

The 2080-TC2 is designed as a Micro800 plug-in module. Confirm that the specific Micro800 controller model supports this module before installation.

It can be installed in an available compatible plug-in slot. However, removal and insertion under power (RIUP) are not supported. Power must be isolated before installing or removing the module.

2. Thermocouple Wiring

Connect the thermocouple conductors to the appropriate input terminals according to the module wiring diagram. Observe thermocouple polarity and use suitable extension or compensation wire for the selected sensor type.

Incorrect polarity or unsuitable wiring can result in inaccurate temperature readings.

3. Cold-Junction Thermistor Installation

Install the supplied external NTC thermistor at terminals A3 and B3 as specified in the manufacturer’s instructions. The thermistor provides the reference temperature information required for cold-junction compensation.

Because the compensation arrangement is common to both channels, its correct installation affects both temperature measurements.

4. Software Configuration

Use Connected Components Workbench software to configure the module. Select the correct thermocouple type for each channel and set appropriate input filter parameters.

The controller program can then use the temperature data for monitoring, alarm handling, and control functions.

5. Electrical Noise Management

Thermocouple signals are relatively low-level signals and can be affected by electrical interference. Keep sensor wiring away from high-voltage cables, motor power conductors, and variable-frequency drive wiring where possible.

Use appropriate shielding and grounding practices in accordance with the installation documentation.

6. Commissioning and Verification

After installation, verify the thermocouple connections, CJC thermistor wiring, and software configuration. Compare the displayed temperature values with a suitable reference instrument where necessary.

Check for open-circuit, overrange, and underrange indications before placing the system into normal operation.

Troubleshooting and Maintenance

Regular inspection and correct sensor configuration help maintain reliable temperature measurement.

Problem Possible Cause Recommended Action
No temperature reading Disconnected thermocouple Inspect sensor wiring and terminal connections
Temperature reading is inaccurate Incorrect thermocouple type selected Verify channel configuration in CCW
Both channels show abnormal readings CJC thermistor incorrectly connected Check the thermistor connection at A3 and B3
Temperature values fluctuate Electrical interference or loose wiring Inspect cable routing, shielding, and terminals
Open-circuit indication Broken sensor wire or loose connection Check thermocouple continuity
Overrange indication Temperature exceeds the configured sensor range Verify actual process temperature and sensor selection
Underrange indication Input is below the configured measurement range Check sensor type, wiring, and process conditions
Module is not recognized Unsupported controller or installation problem Confirm controller compatibility and module seating

Maintenance should include inspecting sensor wiring, checking terminal connections, verifying thermocouple configuration, and confirming that the CJC thermistor remains correctly installed.

Technical FAQs

1. What is the Allen-Bradley 2080-TC2?

It is a two-channel non-isolated thermocouple input plug-in module designed for Allen-Bradley Micro800 programmable controllers.

2. How many thermocouple inputs does the 2080-TC2 provide?

It provides two thermocouple input channels. Each channel can be configured independently for a supported sensor type.

3. Which thermocouple types are supported?

The module supports J, K, N, T, E, R, S, and B thermocouples.

4. Is the 2080-TC2 an isolated input module?

No. It is a non-isolated thermocouple input module. System designers should consider grounding, sensor wiring, and electrical noise when planning the installation.

5. What is the input resolution?

The module provides 14-bit analog input resolution for thermocouple measurements.

6. How does cold-junction compensation work?

The module uses an external NTC thermistor supplied with the unit. It must be connected to terminals A3 and B3 to provide the reference temperature information required for thermocouple measurement.

7. What is the measurement accuracy?

The published input accuracy is ±1.0°C at 25°C. The specified cold-junction compensation error is ±1.2°C at 25°C.

8. Which software is used to configure the module?

Connected Components Workbench software is used to configure the thermocouple type and input filter settings for each channel.

9. Can the 2080-TC2 be removed while the controller is powered?

No. Removal and insertion under power are not supported. Isolate controller power before installing or removing the plug-in module.

10. What should be checked before replacing a 2080-TC2?

Verify the catalog number, controller compatibility, two-channel non-isolated configuration, thermocouple sensor types, CJC thermistor arrangement, and software configuration. Also inspect the existing sensor wiring before commissioning the replacement.

Conclusion

The Allen-Bradley 2080-TC2 Micro800 2-Channel Non-Isolated Thermocouple Input Module provides a compact solution for acquiring temperature signals in industrial automation systems. Its support for eight thermocouple types, 14-bit resolution, configurable input filtering, and external cold-junction compensation makes it suitable for a variety of temperature monitoring and control applications.

For engineers and maintenance teams working with Micro800 controllers, the 2080-TC2 offers a practical way to integrate thermocouple sensors into compact control systems. Correct sensor selection, CJC thermistor installation, and input configuration are essential for dependable temperature measurement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501