| 15980777398 |

The Allen-Bradley 1783-MS10T is a 10-port managed industrial Ethernet switch from the Stratix 8000 family, developed for industrial automation and control network applications. It provides Layer 2 switching capabilities for connecting PLC controllers, operator interfaces, industrial computers, drives, and other Ethernet-enabled equipment.
Designed for industrial environments, the 1783-MS10T combines managed Ethernet connectivity with a compact installation format. It supports network communication between connected devices and provides management functions that help engineers configure and maintain industrial network infrastructure.
The switch is suitable for applications where reliable communication between automation devices is essential. It can be integrated into machine networks, production lines, and industrial control systems that use Ethernet-based communication.
An important consideration for equipment purchasers is that the 1783-MS10T has been discontinued by Rockwell Automation since November 30, 2020. It may therefore be relevant primarily to existing installations, maintenance projects, and spare-parts replacement requirements.
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Model | 1783-MS10T |
| Product Family | Stratix 8000 |
| Product Type | Managed Industrial Ethernet Switch |
| Network Type | Ethernet |
| Total Number of Ports | 10 |
| Switching Layer | Layer 2 |
| Layer 3 Routing | Not supported |
| Management | Managed |
| DC Power Input Range | 18–60V DC |
| Maximum Input Current | 2A |
| Maximum Power Consumption | 15.7W |
| Power Dissipation | 15.7W |
| Alarm Relay Rating | 1A maximum at 30V DC |
| Maximum Inrush Current | 2A |
| Ethernet Connector | RJ45 |
| Recommended Ethernet Cable | Category 5 or Category 5e |
| Isolation Voltage | 75V continuous |
| Protection Rating | IP20 |
| Operating Temperature | -40°C to +60°C |
| Mounting | Industrial panel installation |
| Dimensions | 153 × 117.5 × 148 mm |
| Weight | 0.9 kg |
| Lifecycle Status | Discontinued |
The listed dimensions and weight follow the supplied product information. Rockwell Automation’s published mechanical dimensions are 153 mm wide, 148 mm high, and 117.5 mm deep. Confirm the exact port arrangement and expansion configuration from the unit label and hardware documentation before replacement.
The 1783-MS10T provides ten Ethernet ports for connecting devices within an industrial network. It allows connected equipment to exchange data through a centralized switching device, reducing the need for separate point-to-point connections between individual devices.
Typical connected equipment includes PLC controllers, HMIs, engineering workstations, industrial computers, and compatible network devices.
The switch operates at Layer 2 of the OSI networking model. It forwards Ethernet frames between connected devices based on their MAC addresses.
This functionality supports communication within an industrial local area network and helps organize connections between automation equipment.
Unlike an unmanaged Ethernet switch, the 1783-MS10T provides network management capabilities. These functions allow authorized personnel to configure and maintain the switch according to the requirements of the industrial network.
Management capabilities can help engineers organize network connections, investigate communication problems, and maintain a consistent network configuration.
The switch includes an alarm relay rated for a maximum of 1A at 30V DC. This output can be incorporated into an external monitoring circuit to provide an indication of relevant switch or network conditions.
The alarm circuit should be wired according to the manufacturer’s terminal assignments and electrical ratings.
The 1783-MS10T accepts an 18–60V DC input, making it suitable for industrial DC power arrangements. Its maximum power consumption is 15.7W, excluding the power requirements of any expansion modules.
A suitable power supply should be selected with adequate capacity for the switch and the complete installation.
In manufacturing facilities, PLCs, HMIs, industrial computers, and other networked devices need to exchange operational data. The 1783-MS10T can provide Ethernet connectivity for these components within a production network.
The switch can be used to connect compatible PLC-based control systems with engineering workstations and other Ethernet-enabled devices. This supports communication between control equipment and supervisory systems.
Automated machinery often contains several network-enabled components. The 1783-MS10T can serve as a centralized switching point for communication between controllers, operator terminals, and other industrial equipment.
Process automation installations rely on communication between controllers, monitoring stations, and industrial computers. The switch can form part of the Ethernet infrastructure supporting these connections.
Because the Stratix 8000 family has been used in established industrial installations, the 1783-MS10T may be required when maintaining existing control networks. Keeping a compatible spare can help maintenance teams address hardware failures without immediately redesigning the entire network.
Correct installation is essential for maintaining stable network communication and protecting the switch from electrical and environmental problems.
1. Verify the Hardware Configuration
Before installation, check the complete catalog number, product series, port arrangement, and any installed expansion components. Do not assume that all Stratix 8000 models have identical port configurations.
2. Check the DC Power Supply
The 1783-MS10T requires an 18–60V DC supply. Confirm that the input voltage is within this range and that the supply can provide sufficient current. Observe the correct wiring and grounding requirements.
3. Connect Ethernet Devices
Use compatible RJ45 Ethernet connections and suitable Category 5 or Category 5e cabling. Inspect cables and connectors for damage, and route network cables appropriately to reduce exposure to electrical interference.
4. Configure Network Management
Set up the switch according to the site’s network architecture and maintenance requirements. Confirm addressing, device connectivity, and management access before placing the equipment into normal operation.
5. Test the Alarm Circuit
If the alarm relay is used, verify its wiring and the external monitoring circuit. Ensure that the connected circuit does not exceed the specified 1A at 30V DC rating.
6. Verify Network Communication
After installation, check the power and Ethernet status indicators and confirm communication between the connected devices. Document the final configuration for future maintenance.
Regular inspection can help identify network and power problems before they affect production operations.
| Problem | Possible Cause | Recommended Action |
|---|---|---|
| Switch does not start | DC supply is missing or outside the specified range | Check the power source and terminal connections |
| Ethernet connection is unavailable | Damaged cable or loose connector | Inspect the RJ45 connection and replace faulty cables |
| Communication is intermittent | Cable faults or network configuration problems | Check network connections and switch configuration |
| Connected device cannot be reached | Incorrect network addressing | Verify IP settings and device configuration |
| Alarm relay does not operate as expected | Incorrect external wiring or alarm configuration | Check relay terminals and monitoring circuit |
| Multiple devices lose communication | Switch power interruption or network failure | Inspect the power supply and connected network links |
| Switch overheats | Poor cabinet ventilation or high ambient temperature | Check installation conditions and operating temperature |
| Replacement switch does not communicate correctly | Hardware or configuration mismatch | Compare port configuration, firmware, and network settings |
For long-term maintenance, inspect power terminals, Ethernet connectors, grounding connections, and cabinet conditions. Back up the switch configuration where applicable and keep records of network settings.
1. What is the Allen-Bradley 1783-MS10T?
The 1783-MS10T is a 10-port managed industrial Ethernet switch belonging to the Allen-Bradley Stratix 8000 family.
2. How many Ethernet ports does it provide?
It provides ten Ethernet ports. Confirm the exact interface and expansion configuration using the product documentation for the specific hardware revision.
3. Does the 1783-MS10T support Layer 3 routing?
No. It is a Layer 2 managed switch and does not provide Layer 3 routing capability.
4. What power supply does the 1783-MS10T require?
It operates with an 18–60V DC input. Its maximum input current is 2A.
5. What is its maximum power consumption?
The published maximum power consumption is 15.7W, excluding expansion module power requirements.
6. Does the switch have an alarm relay?
Yes. Its alarm relay has a maximum rating of 1A at 30V DC.
7. What is the operating temperature range?
The specified operating temperature range is -40°C to +60°C.
8. Is the 1783-MS10T still available as a current Rockwell Automation product?
No. Rockwell Automation lists the model as discontinued, with a discontinuation date of November 30, 2020. Availability may depend on remaining inventory and the industrial spare-parts market.
9. Can the 1783-MS10T be replaced by another Stratix switch?
A replacement may be possible, but it should not be selected based only on the number of Ethernet ports. Engineers should compare network functions, port configuration, power requirements, expansion options, firmware, and the existing network design.
10. What should be checked before purchasing a replacement 1783-MS10T?
Verify the full catalog number, hardware series, physical condition, port configuration, power requirements, and compatibility with the existing Stratix 8000 network. For used or surplus equipment, checking the product label and testing the unit before installation are also recommended.
The Allen-Bradley 1783-MS10T Stratix 8000 Ethernet Managed Switch is a 10-port Layer 2 networking device designed for industrial automation applications. Its managed Ethernet functionality, 18–60V DC power input, alarm relay, and industrial operating temperature range make it a useful component in compatible PLC-based network installations.
Although the model is discontinued, it remains relevant to facilities maintaining existing Stratix 8000 infrastructure. Before purchasing or installing a replacement, engineers should carefully verify the hardware configuration, network requirements, power specifications, and compatibility with the existing automation system.