Product Overview The GE IC200UEX122-B VersaMax Micro Expansion Module is a 14-point discrete I/O expansion unit designed to extend the input and output capacity of compatible GE Fanuc VersaMax Micro PLC……
GE IC200UEX122-B VersaMax Miniature Expansion Module
  • GE
  • IC200UEX122-B
  • VersaMax Miniature Expansion Module
  • USA
  • 95 x 90 x 76 mm
  • 0.54 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 39

Our advantage

GE IC200UEX122-B VersaMax Miniature Expansion Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC200UEX122-B VersaMax Miniature Expansion Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC200UEX122-B VersaMax Miniature Expansion Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC200UEX122-B VersaMax Miniature Expansion Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC200UEX122-B VersaMax Micro Expansion Module is a 14-point discrete I/O expansion unit designed to extend the input and output capacity of compatible GE Fanuc VersaMax Micro PLC systems. It provides additional interfaces for connecting industrial sensors, switches, actuators, and other field devices to a programmable logic controller.

In industrial automation, a PLC must receive signals from field devices and send control signals to external equipment. When the number of available I/O points on the main controller is insufficient, an expansion unit can increase the system’s signal-handling capacity without requiring a complete controller replacement.

The IC200UEX122-B operates with a nominal 24 V DC power supply. Its configuration includes eight 24 V DC digital inputs and six DC transistor outputs. The six outputs consist of two high-current channels and four low-current channels, with electronic short-circuit protection.

This combination makes the module suitable for compact automation systems that need both input monitoring and transistor-based output control. Typical connected devices may include pushbuttons, limit switches, proximity sensors, indicator lamps, and compatible DC actuators.

The module is part of the VersaMax Micro platform and is intended for use with compatible Micro PLC configurations. Before installation or replacement, engineers should confirm the complete catalog number, hardware revision, power requirements, terminal arrangement, and controller compatibility.

Technical Specifications

Parameter Specification
Brand GE Fanuc
Manufacturer GE / Emerson Automation
Model IC200UEX122-B
Product Series VersaMax Micro
Product Type Discrete I/O Expansion Unit
I/O Point Count 14 points
Digital Inputs 8 × 24 V DC
Digital Outputs 6 × DC transistor outputs
High-Current Outputs 2 channels
Low-Current Outputs 4 channels
Output Protection Electronic Short-Circuit Protection (ESCP)
Nominal Power Supply 24 V DC
Power Supply Range 19.2–30 V DC
Typical Input Current 0.16 A at 24 V DC
Input Power Rating 4 W
Isolated 24 V DC User Supply Up to 200 mA
Output Supply External 12/24 V DC supply required
Input Logic Positive or negative logic
Dimensions 95 × 90 × 76 mm
Weight Provided 0.54 kg
Typical Application PLC digital I/O expansion and machine control

Note: The dimensions match the published VersaMax Micro expansion-unit dimensions. The supplied weight of 0.54 kg is retained as the listing value; verify whether it represents the module alone or the packaged item.

Function and Working Principle

The IC200UEX122-B expands a VersaMax Micro PLC system by providing additional digital input and output channels. It allows the controller to monitor more field signals and operate additional external devices.

1. Digital Input Signal Acquisition

The module provides eight 24 V DC digital input circuits. These inputs receive discrete signals from field devices and make their states available to the PLC control program.

Typical input devices include:

  • Pushbuttons and selector switches
  • Mechanical limit switches
  • Inductive proximity sensors
  • Photoelectric sensors
  • Compatible electronic switching devices

The input circuits support positive or negative logic configurations. This flexibility allows the module to accommodate different field-device wiring arrangements when configured correctly.

2. Transistor Output Control

The module provides six DC transistor outputs. Two channels are designed for higher-current applications, while the remaining four are low-current outputs.

These outputs allow the PLC to control compatible DC loads, such as indicator lamps, interface relays, and other industrial switching devices.

The output circuits require an external 12/24 V DC power source. Engineers must observe the specified channel and common-current limits when connecting field loads.

3. Electronic Short-Circuit Protection

The six transistor outputs include electronic short-circuit protection (ESCP). This protection helps protect the output circuits when an abnormal short-circuit condition occurs.

The electronic protection design reduces the need for conventional external fusing for the protected output channels. However, it does not eliminate the need for correct wiring, suitable power supplies, and appropriate protection for the overall electrical installation.

4. Integrated 24 V DC User Power

The expansion unit provides an isolated 24 V DC supply for input circuits and compatible field devices, with a maximum available current of 200 mA.

This auxiliary supply can simplify wiring for small sensor installations. The combined current consumed by the input circuits and connected external devices must remain within the specified limit.

5. PLC Signal Processing

The expansion unit works with the compatible VersaMax Micro controller. Input states are made available to the controller, where the PLC program evaluates the signals and determines the required output actions.

For example, when a sensor detects a product on a conveyor, the PLC can process the input state and activate an output to control an indicator or another suitable device.

Role in Industrial Control Systems

The IC200UEX122-B is an I/O expansion component rather than a standalone PLC CPU. Its purpose is to increase the number of field signals that a compatible controller can handle.

PLC System Expansion

The module adds eight digital inputs and six transistor outputs to the control system. This can be useful when a machine requires additional sensors or DC output points after its original installation.

The VersaMax Micro platform supports expansion units, subject to the controller model’s supported expansion capacity and configuration requirements.

Sensor and Switch Integration

The eight input channels allow the PLC to receive signals from multiple field devices. These signals can represent machine position, product presence, operating status, or safety-related interlock conditions.

Any safety-critical function must use an appropriately designed and certified safety system. This standard expansion module should not be treated as a safety-rated I/O device.

Actuator and Indicator Control

The six transistor outputs provide switching signals for compatible DC loads. They can be used for indicator lamps, interface devices, and selected small actuators within the electrical limits of the module.

For loads that exceed the output ratings, an appropriately rated interposing relay or other interface device may be required.

Compact Control Cabinet Integration

The module’s compact 95 × 90 × 76 mm dimensions make it suitable for space-conscious control installations. Its small form factor supports modular system expansion while allowing the main controller to remain in service.

Industrial Applications

1. Packaging Machinery

Packaging machines use digital signals to monitor product position, machine status, and operating sequences. The IC200UEX122-B can provide additional input points for sensors and output points for compatible DC control devices.

It may be used in feeding, counting, product detection, and auxiliary machine-control functions.

2. Conveyor and Material Handling Systems

Conveyor systems often require multiple sensors to detect products, monitor movement, and coordinate different sections of a production line.

The module can collect signals from proximity switches and photoelectric sensors while providing transistor outputs for compatible indicators and control interfaces.

3. Manufacturing Equipment

In manufacturing machinery, discrete signals are used to monitor machine states and coordinate operating sequences. Additional I/O capacity can help accommodate new switches, sensors, and DC output devices.

The module can support compact PLC installations where the original controller requires more digital I/O points.

4. Assembly and Inspection Stations

Automated assembly stations use sensors to confirm component presence, detect workpiece position, and monitor process completion.

The IC200UEX122-B can provide additional signal channels for these functions, allowing the PLC to coordinate different stages of an assembly sequence.

5. General Industrial Automation

The module can also be used in auxiliary control panels, small production machines, and other compatible VersaMax Micro installations where additional 24 V DC discrete I/O is required.

Its application should always be checked against the electrical requirements of the connected field devices.

Installation and System Integration

Correct installation is essential for stable signal acquisition and reliable output operation.

1. Verify Controller Compatibility

Before installing the IC200UEX122-B, confirm that the main PLC supports the required VersaMax Micro expansion configuration.

Check the controller model, supported expansion-unit count, hardware revision, and applicable system documentation.

2. Confirm the 24 V DC Supply

The module requires a nominal 24 V DC supply, with a documented operating range of 19.2–30 V DC.

Verify that the power supply can support the module’s input requirements and the connected field devices. The auxiliary 24 V DC user supply is limited to 200 mA and should not be overloaded.

3. Connect Digital Inputs

Connect field sensors and switches according to the module’s input wiring diagram. Confirm the required positive or negative logic arrangement and ensure that signal references are correctly connected.

Incorrect wiring or incompatible signal voltage may cause unreliable input detection.

4. Connect Transistor Outputs

The six output channels require an external 12/24 V DC supply. The two high-current channels and four low-current channels have different current capabilities.

Observe the individual output and common-current limits. Do not assume that all six channels can operate simultaneously at their individual maximum ratings.

For inductive loads, follow the manufacturer’s requirements for suitable suppression and load protection.

5. Configure the PLC Program

After physical installation, configure the expansion unit in accordance with the controller’s supported hardware setup.

Assign the additional input and output addresses in the PLC program. Verify that the application logic uses the correct I/O references.

6. Test the Installation

After wiring and configuration, test each input channel using its corresponding field device. Verify that the PLC program detects the correct input states.

Then test the transistor outputs under suitable loads. Confirm output switching, protection behavior, and the response of connected devices before returning the machine to normal operation.

Compatible System Components

The IC200UEX122-B is designed for integration into a compatible VersaMax Micro control system.

Component Function Integration Considerations
VersaMax Micro PLC Main controller Confirm expansion support and controller compatibility
24 V DC power supply Provides module operating power Maintain the specified voltage range and sufficient current capacity
Digital sensors Provide field input signals Confirm 24 V DC signal compatibility
Pushbuttons and limit switches Supply discrete machine-status signals Configure input logic and wiring correctly
DC indicator lamps Provide visual machine status Check transistor output current limits
Interface relays Switch external loads Select suitable coil voltage and current
External DC supply Powers transistor output loads Use the required 12/24 V DC supply arrangement
Control cabinet Houses the PLC and expansion equipment Provide suitable mounting and environmental protection
PLC programming software Configures controller logic and I/O assignments Use software and configuration procedures compatible with the installed PLC

The exact accessories and system components required depend on the machine design. They are not necessarily included with the expansion unit.

Alternative Models and Replacement Considerations

When replacing the IC200UEX122-B, the input voltage, output type, number of I/O points, and controller compatibility must be checked carefully.

Related Model General Function Key Difference
IC200UEX014 14-point VersaMax Micro expansion unit 8 × 24 V DC inputs and 6 × 24 V DC outputs
IC200UEX012 14-point VersaMax Micro expansion unit 8 × 24 V DC inputs and 6 relay outputs
IC200UEX011 14-point VersaMax Micro expansion unit 8 × 24 V DC inputs and 6 relay outputs with 120/240 V AC power configuration
IC200UEX214 28-point VersaMax Micro expansion unit 16 inputs and 12 outputs
IC200UEX222 28-point VersaMax Micro expansion unit 16 inputs and 12 protected transistor outputs

These models are related products, not automatic drop-in replacements. Before substitution, compare:

  • Number of digital input and output points.
  • Input voltage and logic configuration.
  • Transistor or relay output type.
  • Individual output current ratings.
  • Common-current limits.
  • Output power supply requirements.
  • Electronic protection features.
  • Controller compatibility and expansion limits.
  • Physical dimensions and terminal arrangements.
  • PLC I/O addressing and program configuration.

A module with the same number of I/O points may still have a different electrical design. Replacement should be based on the complete technical specification rather than appearance alone.

Key Advantages

Additional Digital I/O Capacity

The module adds 14 discrete I/O points, helping expand compatible VersaMax Micro PLC systems without replacing the main controller.

Flexible Input Configuration

Eight 24 V DC inputs support positive or negative logic arrangements, allowing integration with different types of industrial switches and sensors.

Mixed Transistor Output Channels

Two high-current and four low-current transistor outputs provide different output capabilities for compatible DC loads.

Electronic Short-Circuit Protection

ESCP protection helps protect the six transistor output channels against short-circuit conditions.

Integrated Auxiliary 24 V DC Supply

The built-in isolated supply provides up to 200 mA for compatible input circuits and field devices, helping simplify small control installations.

Compact Design

The 95 × 90 × 76 mm dimensions support installation in compact automation panels.

Modular VersaMax Micro Architecture

The expansion unit supports modular system design, allowing additional discrete I/O capacity to be incorporated into compatible controller configurations.

Technical FAQs

1. What is the GE IC200UEX122-B?

It is a 14-point discrete I/O expansion unit from the GE Fanuc VersaMax Micro series. It provides eight 24 V DC digital inputs and six DC transistor outputs.

2. How many input channels does the module have?

The module has eight 24 V DC digital input channels. They support positive or negative logic configurations.

3. How many output channels are available?

It has six DC transistor outputs: two high-current channels and four low-current channels.

4. Does the IC200UEX122-B have output protection?

Yes. Its six transistor outputs include electronic short-circuit protection (ESCP).

5. What power supply does it require?

The module uses a nominal 24 V DC supply, with a documented operating range of 19.2–30 V DC.

6. Does it provide auxiliary power for sensors?

Yes. It provides an isolated 24 V DC user supply with a maximum available current of 200 mA for input circuits and compatible field devices.

7. Can it control relay devices?

The module has transistor outputs rather than built-in relay outputs. It can control compatible DC interface relay coils when their electrical requirements are within the output ratings.

8. Is the IC200UEX122-B a standalone PLC?

No. It is an expansion unit that operates as part of a compatible VersaMax Micro PLC system. It does not replace the main controller.

9. What should be checked before purchasing a replacement?

Verify the full catalog number, hardware revision, input and output configuration, power requirements, physical condition, and compatibility with the installed controller.

10. Is the supplied weight of 0.54 kg correct?

The supplied listing weight is 0.54 kg. However, the VersaMax Micro manual lists approximately 270 g for the IC200UEX122 expansion unit. Confirm whether the listed 0.54 kg includes packaging, accessories, or another configuration before finalizing shipping information.

Procurement and Maintenance Recommendations

When purchasing the GE IC200UEX122-B, verify the complete catalog number and ensure that the unit matches the electrical requirements of the existing VersaMax Micro system.

For replacement projects, compare the input and output specifications carefully. In particular, confirm that the replacement has the same 24 V DC input arrangement, transistor output configuration, channel-current ratings, and electronic protection features.

For used or surplus modules, request clear photographs of the product label, terminal blocks, connectors, and housing. Check for damaged terminals, corrosion, contamination, or signs of overheating. Where possible, request functional testing of the input and output channels.

During maintenance, inspect field wiring, power connections, and connected loads. Confirm that the output supply remains within its permitted range and that the auxiliary 24 V DC supply is not overloaded.

Keep the PLC program and I/O configuration documented. If an expansion module is replaced, verify the I/O assignments and test all connected field devices before resuming automatic operation.

Conclusion

The GE IC200UEX122-B VersaMax Micro Expansion Module is a compact 14-point discrete I/O unit designed to increase the signal-handling capacity of compatible PLC systems. It provides eight 24 V DC inputs and six transistor outputs, including two high-current and four low-current channels with electronic short-circuit protection.

With its 24 V DC power arrangement, auxiliary field-device supply, and compact dimensions, the module is suitable for a range of industrial machine-control and automation applications. Accurate catalog-number verification, correct electrical wiring, and proper controller configuration are essential for reliable operation and replacement.