The GE IC200UER016 VersaMax Micro Expansion Unit is a 16-point relay output expansion module designed for compatible GE Fanuc VersaMax Micro PLC systems. It increases the available discrete output capacity of a controller, allowing the automation system to operate additional field devices without replacing the main controller.
Manufactured for the GE Fanuc VersaMax Micro platform, the IC200UER016 is designed for industrial applications that require reliable relay-based switching. Its 16 normally open relay outputs can control a range of AC and DC loads within the specified electrical ratings. Typical applications include switching solenoid valves, motor starters, indicator devices, and other industrial control components.
The module uses a nominal 24 V DC power supply and provides 16 independent relay output points. Each output supports a maximum resistive load current of 2 A, subject to the specified voltage and load conditions. Its relay contacts can switch 5–30 V DC or 5–250 V AC devices.
The IC200UER016 is particularly useful when an existing VersaMax Micro PLC system requires additional output points. By adding an expansion unit, engineers can extend machine-control functionality while retaining the existing controller architecture.
With compact dimensions of 95 × 90 × 76 mm and a supplied weight of 0.29 kg, the module is suitable for installations where control-panel space is limited. Before installation, users should verify PLC compatibility, expansion-unit capacity, power requirements, and relay contact ratings.
| Parameter | Specification |
|---|---|
| Brand | GE Fanuc |
| Manufacturer | GE Intelligent Platforms |
| Model | IC200UER016 |
| Product Series | VersaMax Micro |
| Product Type | Relay Output Expansion Unit |
| Number of Points | 16 |
| Output Type | Normally Open Relay Outputs |
| Number of Relay Outputs | 16 |
| Output Contact Type | Form A, SPST |
| Maximum Load Current | 2 A per point |
| Maximum Current per Common | 5 A |
| Output Voltage Range | 5–30 V DC or 5–250 V AC |
| Power Supply | 24 V DC nominal |
| Typical Input Current | 0.16 A at 24 V DC |
| Input Power Rating | 4 W |
| Output Response Time | 15 ms maximum |
| Isolation | 1500 V RMS between field and logic sides |
| Group Isolation | 500 V RMS between groups |
| Maximum Leakage Current | 15 mA |
| Dimensions | 95 × 90 × 76 mm |
| Weight | 0.29 kg |
| Compatible Platform | GE Fanuc VersaMax Micro PLC |
| Typical Applications | Industrial machine control, solenoid switching, relay-based output expansion |
Specifications are based on published VersaMax Micro expansion-unit documentation. Confirm the applicable hardware revision and installation manual before commissioning.
The IC200UER016 expands the discrete output capacity of a compatible VersaMax Micro PLC. It receives output commands from the controller and uses internal relay contacts to switch external electrical loads.
The module provides 16 normally open relay output circuits. Each output can be controlled by the PLC program to switch a connected field device.
When an output is activated, the corresponding relay contact changes state and completes the external load circuit. When the output is deactivated, the normally open contact returns to its open state.
This arrangement allows a single PLC system to control multiple devices, including solenoid valves, contactor coils, and indicator equipment.
One important feature of the IC200UER016 is its ability to switch both AC and DC loads within its specified operating range.
The documented output voltage range is:
This flexibility allows the module to interface with different types of industrial field devices. However, the external load must remain within the relay’s voltage and current limits.
For resistive loads, the maximum rated current is 2 A per output. Inductive loads such as solenoids and contactor coils may require additional consideration because their electrical characteristics can increase contact stress.
The module provides electrical isolation between the field side and logic side. Published specifications identify 1500 V RMS isolation between these sides and 500 V RMS between output groups.
Isolation helps separate PLC control circuitry from external field circuits. It is an important feature when integrating control electronics with industrial loads operating at different electrical potentials.
Appropriate wiring, grounding, and protective measures are still required.
The IC200UER016 does not directly supply operating power to every connected field device. Instead, its relay contacts switch power from an appropriate external AC or DC source.
For example, a PLC output command can activate a relay contact that completes the circuit for a solenoid valve. The external power supply provides the energy required by the valve.
This arrangement makes it possible to use the module with different types of field equipment, provided that the electrical ratings are respected.
The documented maximum response time is 15 ms for both ON-to-OFF and OFF-to-ON transitions.
This switching performance is appropriate for many general-purpose industrial control applications. However, relay outputs are electromechanical devices and are not intended to provide the extremely high switching frequency of solid-state transistor outputs.
Applications involving rapid repetitive switching should be evaluated carefully before selecting this module.
The IC200UER016 operates as an output expansion device within a VersaMax Micro PLC architecture. It allows the controller to manage more field devices while keeping the main control system compact.
A PLC program processes input signals and executes control logic. When the program determines that an output device should operate, it sends the corresponding command to the expansion unit.
The IC200UER016 then switches the appropriate relay contact to control the connected field circuit.
This arrangement is useful when an existing machine requires additional output points for new actuators, valves, indicators, or auxiliary equipment.
In automated machinery, output points are used to control devices according to production sequences. The IC200UER016 can provide additional relay-controlled outputs for machine functions such as:
The PLC program determines the operating sequence, while the relay output unit performs the electrical switching.
Industrial process systems often contain multiple actuators that must respond to sensor signals and controller commands.
The IC200UER016 can expand the number of relay-controlled devices available to a compatible VersaMax Micro PLC. This is useful in small process skids, utility equipment, and auxiliary control panels.
The compact form factor allows the unit to be incorporated into suitable industrial control-panel layouts. Engineers should provide adequate space for wiring, connector access, ventilation, and maintenance.
The expansion connection must follow the VersaMax Micro hardware documentation and the requirements of the specific controller.
The IC200UER016 is designed for applications requiring additional relay output points in a compatible VersaMax Micro PLC system.
Solenoid valves are commonly used to control compressed air, water, oil, and other process fluids.
The IC200UER016 can switch compatible solenoid valve circuits through its relay contacts. A PLC program can activate individual outputs according to pressure signals, level conditions, timing sequences, or machine operating states.
The current requirements of each solenoid coil must be checked before connection.
Industrial motors are commonly operated through contactors or motor starters. The IC200UER016 can control suitable contactor coil circuits as part of a PLC-based motor-control system.
The module does not directly provide motor power. It switches the control circuit associated with the contactor, while the motor power circuit is handled by appropriately rated switching and protection equipment.
Packaging equipment often requires multiple output signals for actuators, valves, indicators, and auxiliary functions.
The 16 relay outputs can provide additional control points for compatible devices. PLC logic can coordinate these outputs with sensors and machine operating sequences.
Conveyors, transfer equipment, and sorting machines use multiple actuators and auxiliary devices.
The IC200UER016 can support relay-based control of suitable devices, including contactors, solenoids, and signaling equipment. This helps extend the output capacity of an existing controller.
Industrial machines often require visual and audible indicators to communicate operating conditions.
The module can switch compatible indicator circuits and alarm devices according to PLC logic. Electrical ratings and load characteristics must be checked before connecting these devices.
The IC200UER016 can be used in various small and medium-sized automation applications where additional relay outputs are required. Its suitability depends on the controller architecture, expansion capacity, load type, and switching frequency.
Correct installation is essential for reliable operation and electrical safety.
Before installing the IC200UER016, confirm that the existing controller belongs to the compatible VersaMax Micro platform.
Check the controller’s hardware revision, firmware requirements, supported expansion-unit count, and expansion connection arrangement.
The VersaMax Micro architecture supports expansion configurations, but the permitted number and combination of expansion units depend on the controller model and system requirements.
The module requires a nominal 24 V DC power supply.
The documented input range is 24 V DC with a tolerance of -20% to +25%. The typical input current is approximately 0.16 A at 24 V DC, with a 4 W input power rating.
Ensure that the power supply has sufficient capacity for the expansion unit and other connected control equipment.
Install the expansion unit using the correct expansion cable and connection method specified for the VersaMax Micro system.
Ensure that the connector is fully seated and that the module is securely mounted. Avoid excessive cable bending or mechanical stress on the connection.
Connect each relay output to the appropriate external load circuit.
Before wiring, identify the output terminal assignments and common connections from the module’s wiring documentation.
Important considerations include:
Configure the PLC application to recognize and operate the expansion outputs according to the system’s I/O mapping.
Each output point should be assigned to the intended field device. Test the program logic and verify that the correct relay activates when the corresponding command is issued.
After installation, inspect the wiring and confirm the power supply voltage.
Test each output individually and verify that the connected device operates correctly. Check the switching sequence, interlocks, and fault responses before returning the equipment to normal production.
Document the final I/O mapping and wiring arrangement for future maintenance.
The IC200UER016 is designed for use within a compatible GE Fanuc VersaMax Micro PLC system.
| Component | Function | Integration Considerations |
|---|---|---|
| VersaMax Micro PLC | Executes control logic | Verify supported expansion configuration |
| IC200UER016 | Provides 16 relay outputs | Main output expansion unit |
| IC200CBL501 | Expansion connection cable | Confirm the correct cable is included or available |
| 24 V DC power supply | Supplies module operating power | Verify voltage and current capacity |
| Solenoid valves | Operate pneumatic or hydraulic circuits | Check coil voltage and current |
| Motor contactors | Switch motor power circuits | Verify contactor coil requirements |
| Indicator lamps | Provide machine status indication | Confirm electrical ratings |
| Circuit protection devices | Protect field wiring and loads | Select according to circuit requirements |
| Control cabinet | Houses PLC and expansion equipment | Provide suitable mounting and wiring space |
The exact combination of components depends on the controller model and application design. Accessories should be checked against the applicable hardware documentation.
When replacing the IC200UER016, engineers should compare the number of output points, output technology, voltage range, current ratings, power requirements, and controller compatibility.
| Related Model | Main Function | Key Difference |
|---|---|---|
| IC200UER008 | 8-point relay output expansion | Provides 8 relay outputs instead of 16 |
| IC200UEO016 | 16-point 24 V DC transistor output expansion | Uses transistor outputs rather than relay contacts |
| IC200UEO116 | 16-point 24 V DC transistor output expansion | Different output technology and electrical characteristics |
| IC200UEC208 | 4-input / 4-relay-output expansion unit | Combines input and relay output functions |
| IC200UEX012 | 14-point VersaMax Micro expansion unit | Provides 8 DC inputs and 6 relay outputs |
These models are related VersaMax Micro products, not automatically interchangeable replacements.
Before selecting an alternative, verify:
A transistor output module may not replace a relay output module without changes to the field wiring and control design.
The module provides 16 normally open relay outputs, allowing a compatible PLC system to control additional field devices.
Its relay contacts can switch specified AC and DC loads, providing flexibility for different industrial control circuits.
Isolation between the logic side and field side helps separate controller electronics from external load circuits.
The 95 × 90 × 76 mm dimensions make the unit suitable for compact industrial control installations.
The module extends the output capacity of compatible VersaMax Micro PLC systems without requiring a completely different controller architecture.
Relay outputs can be used for compatible solenoids, contactor coils, indicators, and other switching applications.
The IC200UER016 is a GE Fanuc VersaMax Micro 16-point relay output expansion unit. It adds 16 normally open relay outputs to a compatible PLC system.
It provides 16 relay output points.
The documented maximum resistive load current is 2 A per output, with a maximum of 5 A per common. Actual application limits depend on voltage and load characteristics.
The specified operating range is 5–30 V DC or 5–250 V AC.
The module requires a nominal 24 V DC power supply.
Yes. Its relay outputs can switch compatible solenoid valve circuits, provided that the coil voltage and current remain within the specified limits.
Yes. It can be used to switch suitable motor-contactor control circuits. It does not directly supply power to the motor.
No. It is a relay output expansion unit with 16 normally open relay circuits.
The IC200UER008 provides 8 relay output points, while the IC200UER016 provides 16 relay output points. Both belong to the VersaMax Micro expansion family.
Verify the complete model number, physical condition, terminal condition, relay operation, included expansion cable, and compatibility with the installed VersaMax Micro controller.
When sourcing the GE IC200UER016, confirm that the model number matches the required 16-point relay output configuration. Do not confuse it with VersaMax Micro expansion units that use transistor outputs or combined input/output configurations.
For used or refurbished equipment, request clear photographs of the product label, terminals, housing, and connectors. Where possible, obtain information about relay switching tests and the module’s operating history.
During maintenance, inspect the relay terminals and field wiring for loose connections, discoloration, or signs of overheating. Check that connected loads remain within the specified voltage and current ratings.
Relay contacts are electromechanical components and have finite mechanical and electrical service lives. Switching frequency, load type, and electrical stress affect contact life. Inductive loads should be evaluated carefully because they can produce switching transients and accelerate contact wear.
Maintain accurate PLC I/O documentation so that each output point can be identified during troubleshooting or replacement. Before servicing, isolate the relevant power circuits and follow the site’s electrical safety procedures.
The GE IC200UER016 VersaMax Micro Expansion Unit is a 16-point relay output module designed to expand the discrete output capacity of compatible GE Fanuc VersaMax Micro PLC systems.
With 16 normally open relay outputs, 24 V DC operating power, and support for specified AC and DC load voltages, it provides a practical solution for controlling compatible solenoid valves, contactor coils, indicators, and other industrial field devices.
Its compact dimensions and integration with the VersaMax Micro platform make it useful for industrial maintenance and machine-control applications. Correct controller compatibility, load ratings, wiring, and commissioning procedures are essential for reliable operation.