Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE IC200UDR002 VersaMax Microcontroller is a compact programmable logic controller (PLC) designed for small-scale industrial automation and machine-control applications. It belongs to the GE Fanuc VersaMax Micro PLC family and integrates processing, digital input, relay output, and power supply functions into one compact controller.
Unlike modular PLC systems that require separate CPU, input, output, and power modules, the IC200UDR002 combines essential control functions in a single unit. This integrated design helps simplify control-panel layouts and provides a practical solution for machines that require a moderate number of digital signals.
The IC200UDR002 is a 14-point Micro PLC with eight 24 V DC digital inputs and six normally open relay outputs. It operates from a nominal 24 V DC power supply and supports high-speed counter functions for applications involving pulse signals, counting, and basic machine monitoring.
The controller can receive signals from industrial sensors, push buttons, limit switches, and other field devices. Based on the application program, it processes these signals and controls connected equipment through its relay outputs.
The VersaMax Micro platform also provides an RS-232 serial communication interface supporting applicable GE serial communication protocols. This allows the controller to exchange data with compatible programming equipment and external devices.
The IC200UDR002 is suitable for compact machinery, auxiliary equipment, small production systems, and standalone automation tasks where integrated digital I/O and relay-based control are sufficient.
| Parameter | Specification |
|---|---|
| Brand | GE / GE Fanuc |
| Product Series | VersaMax Micro |
| Model | IC200UDR002 |
| Product Type | 14-Point Micro PLC |
| Controller Type | Integrated Programmable Logic Controller |
| Total I/O Points | 14 |
| Digital Inputs | 8 |
| Input Signal Type | 24 V DC, positive/negative logic |
| Digital Outputs | 6 |
| Output Type | Normally Open Relay |
| Relay Output Rating | 2 A per output |
| Relay Operating Voltage | 5–30 V DC or 5–250 V AC |
| Controller Supply Voltage | 24 V DC nominal |
| Power Input Range | 19.2–30 V DC |
| Power Consumption | 4 W |
| High-Speed Counter | Supported |
| Counter Configuration | Up to four Type A or one Type A and one Type B |
| Serial Communication | RS-232 |
| Serial Port Connector | RJ-45 |
| Auxiliary 24 V DC Output | 200 mA maximum |
| Program Memory | 9K words |
| Register Memory | 256 words |
| Typical Scan Rate | 1.1 ms/K for Boolean logic |
| Dimensions Provided | 95 × 90 × 76 mm |
| Weight Provided | 0.43 kg |
Note: The manufacturer’s manual specifies a typical module weight of approximately 0.30 kg. The supplied 0.43 kg is retained as the listing weight and should be checked against the actual unit and packaging.
The IC200UDR002 operates as an integrated controller that monitors input signals, executes a stored control program, and changes output states according to programmed logic.
Its main operating functions include digital signal acquisition, logical processing, relay-based output control, and high-speed counting.
The controller provides eight 24 V DC digital input circuits. These inputs receive signals from external field devices, including:
When an input changes state, the controller detects the signal and makes the corresponding input information available to the application program.
The eight input channels support positive or negative logic configurations. Engineers should verify the selected wiring arrangement and electrical characteristics before connecting field devices.
The controller processes input information according to the application program stored in its memory.
Typical control logic may include:
The IC200UDR002 provides a typical Boolean logic scan rate of approximately 1.1 ms per thousand Boolean instructions. Actual application execution time depends on program structure and the functions being processed.
The controller has six normally open relay output circuits. These outputs can control compatible AC or DC devices, such as indicator lamps, small contactor coils, and other control loads.
The documented relay operating voltage range is 5–30 V DC or 5–250 V AC, with a maximum resistive load rating of 2 A.
Relay outputs provide electrical switching through mechanical contacts. They are suitable for applications where relay-based switching is required, but they should not be treated as high-speed transistor outputs.
For inductive loads, appropriate suppression and protection should be considered to reduce electrical stress on relay contacts.
The IC200UDR002 supports high-speed counter configurations for applications that require pulse counting.
Depending on the selected configuration, it can support up to four Type A counters or one Type A and one Type B counter.
These functions can be used for:
The counter configuration and wiring must follow the controller’s technical documentation. Relay outputs should not be confused with high-speed pulse-train or PWM outputs.
The integrated RS-232 serial interface supports communication with compatible external devices and programming equipment.
The documented serial protocols include SNP/SNPX, RTU slave protocols, and Serial I/O functions, subject to the applicable configuration.
This interface can support program access, data exchange, and connection to compatible operator or monitoring equipment.
The GE IC200UDR002 can serve as the primary controller for a compact machine or as a dedicated control unit within a larger industrial installation.
Its integrated design combines processing and digital I/O, reducing the need for separate modules in applications with limited signal requirements.
For smaller machines, the IC200UDR002 can execute the complete control sequence without requiring a separate modular PLC CPU.
For example, a machine may use digital inputs to detect product presence, verify safety-related interlock status through an appropriately designed safety system, and monitor operating switches. The PLC then processes the signals and controls outputs according to the programmed sequence.
The eight digital inputs allow the controller to receive signals from compatible field sensors. Its six relay outputs can switch suitable external control circuits.
This arrangement is useful for basic automation tasks such as controlling pumps, small motors through contactors, indicator lights, and other auxiliary equipment.
The output current and load type must remain within the relay specifications.
The RS-232 serial port can be used with compatible programming or communication equipment. An external HMI may also be integrated where the required protocol and connection method are supported.
Before designing an HMI connection, engineers should verify the device driver, communication settings, cable arrangement, and protocol compatibility.
The VersaMax Micro platform supports expansion arrangements for suitable models and configurations. Where additional I/O is required, the specific expansion capability of the IC200UDR002 and compatible accessories should be checked against the manufacturer’s documentation.
For applications with larger I/O requirements, more communication interfaces, or advanced motion functions, a different PLC platform may be more appropriate.
The IC200UDR002 is designed for compact control applications where eight digital inputs and six relay outputs provide sufficient capacity.
The controller can manage basic operating sequences in small manufacturing equipment. It can monitor machine switches and sensors, process operating conditions, and control relay-connected devices.
Typical applications include simple assembly equipment, small processing machines, and auxiliary production units.
Small conveyor systems often require basic start/stop logic, product detection, and counting functions.
The IC200UDR002 can receive signals from product-detection sensors and execute programmed conveyor-control sequences. Its relay outputs can operate compatible contactors or auxiliary control circuits.
For systems with several conveyor zones or complex synchronization requirements, additional controllers or a larger PLC may be necessary.
The controller can be used in small pump-control panels where digital signals are sufficient for monitoring and basic operation.
Possible functions include:
The PLC relay outputs should operate suitable control devices rather than directly switching motor loads beyond their ratings.
Packaging machinery may use digital sensors to detect product position, monitor machine states, and coordinate simple operating sequences.
The controller’s digital inputs and relay outputs can support basic feeding, counting, and auxiliary control functions.
Applications requiring high-speed positioning, extensive motion control, or sophisticated communication should be evaluated against the capabilities of a more advanced controller.
The IC200UDR002 may also be used in compact utility-control applications, including basic ventilation, auxiliary pump systems, and equipment-status monitoring.
Its integrated I/O arrangement is suitable for small systems where the number of field signals is limited.
The high-speed counter capability makes the controller useful for selected counting and pulse-monitoring tasks.
For example, it may count products passing a sensor or monitor pulses generated by compatible equipment. The maximum supported counting performance depends on the input configuration and application requirements.
Correct installation is essential for stable operation and reliable signal processing.
The IC200UDR002 uses a nominal 24 V DC power supply. Its documented operating input range is 19.2–30 V DC.
The power supply must provide sufficient current during startup. The manufacturer’s documentation specifies a minimum transient current capability of 2.0 A for startup, so the selected supply should be checked against the controller’s inrush requirements.
The controller’s typical input current is approximately 0.16 A at 24 V DC, with a rated input power of 4 W. These values should not be used alone to size the supply without considering startup requirements and connected user devices.
The supplied product dimensions are 95 × 90 × 76 mm.
Before designing the control cabinet, verify the actual mounting arrangement, terminal access, connector clearance, and required installation spacing.
The controller should be installed in an appropriate industrial enclosure with protection against excessive dust, moisture, vibration, and electrical interference.
Allow sufficient space for field wiring and maintenance access.
Connect compatible 24 V DC sensors and switches to the input terminals according to the selected positive or negative logic arrangement.
Check the polarity, common connections, and input voltage levels before energizing the system.
Incorrect wiring can result in false input states or damage to the controller.
The six relay outputs provide normally open contacts. Each output can switch compatible AC or DC loads within the specified ratings.
When connecting contactors, solenoids, or other inductive devices, use suitable suppression components where required.
For loads exceeding the relay rating, use an appropriately rated external contactor or relay.
The controller provides an RS-232 serial port using an RJ-45 connector.
Communication setup should include verification of:
Use the correct programming cable and communication settings for the target software and connected equipment.
After wiring is complete, load or verify the application program using compatible VersaMax Micro programming tools.
Commissioning should include:
A backup of the application program should be maintained for future troubleshooting and equipment replacement.
The IC200UDR002 can be used with compatible sensors, actuators, power supplies, communication equipment, and control-panel components.
| Component | Function | Integration Considerations |
|---|---|---|
| 24 V DC power supply | Supplies operating power to the PLC | Must meet voltage and startup current requirements |
| Proximity sensor | Detects nearby objects | Verify 24 V DC signal compatibility |
| Photoelectric sensor | Detects product presence or position | Check output type and input wiring |
| Limit switch | Provides mechanical position feedback | Verify contact configuration |
| Push-button station | Provides manual operator commands | Connect according to the input logic arrangement |
| Relay or contactor | Switches external loads | Use suitable coil voltage and protection |
| Indicator lamp | Displays operating status | Verify voltage and relay contact rating |
| HMI | Provides operator monitoring and control | Confirm RS-232 protocol and driver compatibility |
| Programming cable | Connects the PLC to programming equipment | Verify connector pinout and communication support |
| Control cabinet | Protects installed automation equipment | Provide suitable environmental protection and wiring space |
These components are examples of devices that may be used in a complete control installation. They are not necessarily included with the IC200UDR002.
When replacing an IC200UDR002, the alternative controller must be checked against the original I/O configuration, supply voltage, communication requirements, and application program.
| Alternative Model | General Description | Replacement Considerations |
|---|---|---|
| GE IC200UDR001 | VersaMax Micro PLC with 8 DC inputs and 6 relay outputs | Uses a different power supply configuration; verify supply compatibility |
| GE IC200UDR003 | VersaMax Micro PLC with 8 DC inputs and 6 relay outputs | Uses a different input voltage configuration |
| GE IC200UDD104 | VersaMax Micro PLC with DC inputs and transistor outputs | Output type and electrical characteristics differ |
| GE IC200UDR005 | VersaMax Micro PLC | Verify I/O arrangement, supply, and communication requirements |
| GE VersaMax modular PLC | Modular automation controller family | May require separate CPU, power, and I/O modules |
| Modern compact PLC | Current-generation integrated controller | May require program conversion, wiring changes, and recommissioning |
A replacement should be selected only after reviewing the complete technical requirements.
Important comparison points include:
A controller with the same number of I/O points is not necessarily a direct replacement. Differences in output type, terminal arrangement, communication protocol, and programming software can affect system compatibility.
The IC200UDR002 combines processing, digital inputs, relay outputs, and power supply functions in one compact controller. This can simplify installations where a separate modular PLC system would be unnecessary.
The eight digital inputs support signals from common industrial sensors, switches, and operator devices.
The six normally open relay outputs support compatible AC and DC control loads within their specified electrical limits.
The integrated counter functions support selected pulse-counting and monitoring applications without requiring a separate counter module.
The serial interface supports communication with compatible programming and external devices using supported protocols.
The integrated design and small physical dimensions make the controller suitable for compact control cabinets and standalone machine panels.
The VersaMax Micro family is used in existing industrial installations. Maintaining the exact model can help reduce unnecessary changes to established machine-control systems.
The GE IC200UDR002 is a 14-point VersaMax Micro PLC. It integrates eight 24 V DC digital inputs and six normally open relay outputs in one controller.
It has eight digital inputs and six relay outputs, providing 14 integrated I/O points.
It uses a nominal 24 V DC supply with a documented operating range of 19.2–30 V DC.
It provides six normally open relay outputs. The documented relay operating voltage is 5–30 V DC or 5–250 V AC, with a maximum resistive load rating of 2 A.
Yes. It supports up to four Type A high-speed counters or one Type A and one Type B counter, depending on the selected configuration.
The controller includes an RS-232 serial interface with an RJ-45 connector. Supported communication functions include SNP/SNPX, RTU slave protocols, and Serial I/O, subject to configuration.
The relay outputs are intended for compatible control loads and should not be used to switch motor loads that exceed their electrical ratings. For motor control, use appropriately rated contactors or other suitable motor-control equipment.
Yes. It is an integrated Micro PLC with an onboard controller and I/O. It can execute a suitable application program without a separate modular CPU.
Verify the full model number, physical condition, terminal condition, power-up behavior, input and output operation, communication interface, and availability of the original application program.
The supplied listing weight is 0.43 kg. The manufacturer’s manual lists a typical module weight of approximately 0.30 kg. Confirm whether the higher figure includes packaging, accessories, or a different weighing basis before using it for shipping calculations.
When sourcing the GE IC200UDR002, confirm the complete model number and inspect the controller’s physical condition. Check the terminal blocks, connector condition, housing, and visible signs of heat damage or corrosion.
For used or refurbished units, request photographs of the product label and connection terminals. Where possible, obtain functional test information covering power-up, digital inputs, relay outputs, and serial communication.
The original application program is particularly important in replacement projects. Before removing an existing controller, back up the program and record its configuration, wiring assignments, and communication settings.
During maintenance, inspect terminal connections and field wiring periodically. Confirm that the 24 V DC supply remains within the specified range and can provide sufficient startup current. Relay contacts should also be checked when switching loads with frequent operating cycles.
If the controller is being replaced with another PLC, evaluate the complete control system rather than comparing only the number of I/O points. Differences in signal type, communication, programming environment, and terminal layout may require engineering modifications.
The GE IC200UDR002 VersaMax Microcontroller is a compact 14-point integrated PLC designed for small industrial automation systems. It provides eight 24 V DC digital inputs, six normally open relay outputs, high-speed counter support, and an RS-232 communication interface.
Its integrated architecture makes it suitable for compact machinery, auxiliary equipment, small conveyor systems, and basic process-control applications. For maintenance and replacement projects, verifying the power supply, I/O configuration, communication requirements, and original application program is essential to achieving reliable system integration.