Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE IC200MDL740B VersaMax Discrete Output Module is a digital output module designed for industrial automation and programmable logic controller (PLC) applications. It belongs to the GE Fanuc VersaMax distributed I/O product family and provides 16 discrete DC output points for controlling external field devices.
The module converts output commands from a VersaMax PLC CPU or network interface unit into electrical switching signals. These signals can operate compatible devices such as indicator lamps, interposing relays, solenoid valves, and other DC-controlled equipment.
The IC200MDL740B uses a positive-logic, sourcing output configuration. In this arrangement, an activated output supplies positive DC voltage to the connected load. The module supports a nominal 12/24 V DC operating range, with an external field power supply required for output operation.
Each output point supports a maximum resistive load current of 0.5 A at 30 V DC. The module provides 16 outputs in one group, making it suitable for applications that require multiple independently controlled digital signals within a compact PLC installation.
The IC200MDL740B is an important component in VersaMax automation systems where reliable switching of field devices is required. Its individual output status LEDs help maintenance personnel identify output conditions during commissioning and troubleshooting.
The module must be installed with a compatible VersaMax carrier base. Its electrical configuration, external power requirements, and output current limitations should be checked before connecting field equipment.
| Parameter | Specification |
|---|---|
| Manufacturer | GE Fanuc / GE Intelligent Platforms |
| Product Series | VersaMax |
| Model Number | IC200MDL740B |
| Product Type | Discrete Output Module |
| Module Category | Digital Output Module |
| Number of Output Points | 16 |
| Output Configuration | Positive Logic / Sourcing |
| Output Voltage | 10.2–30 V DC |
| Nominal Voltage | 12/24 V DC |
| Maximum Load Current | 0.5 A per point at 30 V DC, resistive |
| Maximum Inrush Current | 2.0 A for 100 ms |
| Output Groups | 1 group of 16 outputs |
| External Power Supply | Required |
| Backplane Current Consumption | 45 mA maximum at 5 V DC |
| Maximum Output Voltage Drop | 0.3 V |
| Maximum Output Leakage Current | 0.5 mA at 30 V DC |
| ON Response Time | 0.2 ms maximum |
| OFF Response Time | 1.0 ms maximum |
| Output Protection | No internal fuse |
| Status Indicators | Individual output LEDs, FLD PWR, OK |
| Isolation | Optical isolation between user input and logic; no point-to-point isolation |
| Module ID | FFFF8080 |
| Dimensions Provided | 110 × 66.8 × 50 mm |
| Weight Provided | 0.231 kg |
| Mounting | VersaMax carrier base |
| Typical Application | Industrial digital output control |
Specifications should be checked against the exact hardware revision and applicable installation documentation. The stated dimensions exclude the carrier and mating connectors.
The IC200MDL740B operates as the output interface between a VersaMax PLC system and external industrial equipment. It receives digital output data from the CPU or network interface unit and uses that information to switch connected DC loads.
The PLC program determines when an output point should be activated or deactivated. The module receives the corresponding output data through the VersaMax backplane.
Each of the 16 output points corresponds to a digital control signal. When the PLC activates a point, the module switches the associated output circuit to supply power to the connected field load.
This arrangement allows a PLC to control several independent devices using a single output module.
The IC200MDL740B uses positive-logic sourcing outputs. A sourcing output supplies positive DC voltage to the load when activated.
For example, when a PLC program activates an output connected to an indicator lamp, the module supplies the required DC voltage through the output circuit. The lamp illuminates when the electrical circuit is completed.
This output arrangement is commonly used in industrial control systems with 12 V or 24 V DC field devices.
The module requires an external DC power supply to switch power to connected loads. The VersaMax backplane supplies the module’s internal logic power, while the external field supply provides the electrical energy used by the output circuits.
Separating these power functions helps engineers design the PLC logic system and field-device power distribution according to their individual requirements.
The external supply must be compatible with the module’s voltage range and the connected devices. The total current demand must also remain within the permitted electrical limits.
The IC200MDL740B has a maximum ON response time of 0.2 ms and a maximum OFF response time of 1.0 ms.
These response characteristics allow the module to handle normal industrial digital control operations, including switching indicator lamps, relays, and other compatible devices.
The actual response of a complete machine also depends on PLC scan time, field-device characteristics, wiring, and the mechanical response of the connected equipment.
The module includes individual LEDs for the 16 output points. These indicators show the logical ON/OFF status of each output.
Two additional indicators provide important system information:
These indicators help maintenance personnel identify missing field power, backplane power problems, and output-command conditions during troubleshooting.
The IC200MDL740B provides the digital output interface required to connect PLC logic with external equipment. It is commonly used as part of a VersaMax distributed I/O system.
A VersaMax PLC CPU executes the control program and determines the operating conditions of connected equipment. The output module receives the relevant digital data and switches the corresponding field circuits.
For example, a PLC may activate an output when a sensor detects a product at a conveyor station. The output module can then energize a compatible relay or solenoid valve to initiate the next operation.
The module supports 16 independently controlled output points. This allows one module to operate several devices within the same machine or process area.
Typical connected equipment includes:
The electrical specifications of every connected device must be checked before installation.
In a distributed control architecture, input and output modules can be installed near the equipment they serve. The VersaMax system can communicate with the controller through the appropriate network interface unit.
This approach can reduce long field wiring runs and provide a modular arrangement for machine expansion and maintenance.
The IC200MDL740B can therefore serve as a field-level output component in manufacturing systems, process equipment, and automated production lines.
Manufacturing equipment often requires multiple digital output signals to control machine operations.
The IC200MDL740B can switch compatible DC control devices according to PLC logic. For example, it may operate indicator lamps, relay coils, and auxiliary actuators during different stages of a production sequence.
Its 16-point configuration provides a compact solution for equipment requiring several digital outputs.
Conveyor systems use digital outputs to coordinate motors, indicators, diverters, and auxiliary mechanisms.
A PLC can activate specific output points according to sensor signals and production conditions. The IC200MDL740B can provide the switching signals for compatible DC devices used in these operations.
For motor starters or higher-current loads, appropriately rated interposing relays or contactors should be used rather than connecting the load directly to the module.
Industrial pneumatic and hydraulic systems frequently use electrically operated solenoid valves.
The module can control compatible DC solenoid valve circuits within its electrical limits. When the PLC activates an output, the module supplies voltage to the valve coil, causing the valve to change position.
Before connecting a valve, engineers should check coil voltage, current consumption, inrush characteristics, and inductive-load suppression requirements.
Packaging equipment often requires digital signals to control feeding mechanisms, positioning devices, and auxiliary operations.
The IC200MDL740B can provide output signals for compatible DC control devices, allowing the PLC to coordinate different machine stages.
Its individual output indicators can also help technicians identify which control points are active during troubleshooting.
In industrial process systems, digital outputs are used to operate alarms, relay interfaces, valve controls, and other binary field devices.
The module can provide the required switching signals for suitable equipment while the PLC manages the overall process sequence.
The module’s output current and voltage limitations must be considered when designing field connections.
Correct installation is essential for stable output operation and reliable integration with the VersaMax PLC system.
The IC200MDL740B requires a compatible VersaMax carrier base. The carrier provides the mechanical mounting arrangement and electrical connection to the system backplane.
Before installation, confirm that the carrier model and system configuration support the selected module.
The module requires an external DC supply for field output operation.
The supported output voltage range is 10.2–30 V DC, with 12/24 V DC nominal operation. The external supply should be selected according to the connected loads and their combined current requirements.
For 12 V operation, the IC200MDL740B revision is important. Earlier IC200MDL740 versions may not support the same 12 V functionality.
Each output point should be connected according to the module’s wiring diagram and the requirements of the field device.
Verify the positive supply, output terminal, return path, and common wiring arrangement before energizing the system.
Avoid exceeding the maximum current rating of 0.5 A per point. The module has no internal fuse for each output, so external circuit protection should be designed as required by the application.
Relays and solenoid valves are inductive loads. When their coils are switched off, they may generate voltage transients.
Use suitable suppression components, such as flyback diodes or other manufacturer-approved suppression devices, where required by the load and circuit design.
This helps reduce electrical interference and protects connected control equipment.
Because the IC200MDL740B uses positive-logic sourcing outputs, the field wiring and connected devices must be designed for this output type.
A sourcing output is not directly interchangeable with a sinking output. Incorrect wiring can prevent the connected equipment from operating or cause electrical faults.
After installation, verify the module’s backplane connection and field power supply.
Test each output point individually and confirm that the connected field device responds correctly. Check the output LEDs, FLD PWR indicator, and OK indicator during commissioning.
Record the final wiring assignments and PLC output addresses for future maintenance.
The IC200MDL740B operates as part of the GE Fanuc VersaMax automation platform.
| Component | Function | Integration Considerations |
|---|---|---|
| VersaMax PLC CPU | Executes control logic | Provides output data to the I/O system |
| VersaMax NIU | Connects distributed I/O to a control network | Must match the network architecture |
| IC200CHS carrier base | Provides module mounting and backplane connection | Confirm carrier compatibility |
| 24 V DC power supply | Supplies field-device power | Check total load current and voltage stability |
| Interposing relay | Switches loads requiring different electrical ratings | Select coil voltage and contact ratings correctly |
| Solenoid valve | Converts electrical commands into mechanical valve movement | Verify coil voltage and current |
| Indicator lamp | Provides visual operating status | Confirm DC voltage and current |
| PLC programming software | Configures and maintains the control application | Verify compatibility with the installed VersaMax CPU |
| Field terminal wiring | Connects module outputs to external devices | Follow the module wiring diagram |
These components are examples of equipment used in a complete installation. They are not necessarily supplied with the IC200MDL740B.
When replacing an IC200MDL740B, engineers should compare output type, voltage range, point count, current rating, and protection features.
| Model | Description | Main Difference |
|---|---|---|
| IC200MDL740 | VersaMax 12/24 V DC positive-logic output module | Earlier catalog versions; confirm revision for 12 V functionality |
| IC200MDL741 | VersaMax 24 V DC positive-logic output module | Includes electronic short-circuit protection |
| IC200MDL730 | VersaMax 24 V DC positive-logic output module | 8 points, 2.0 A per point |
| IC200MDL750 | VersaMax 12/24 V DC positive-logic output module | 32 output points |
| IC200MDL742 | VersaMax 24 V DC positive-logic output module | 32 points with electronic short-circuit protection |
A replacement should not be selected based only on the product family. The following parameters should be checked:
For critical industrial equipment, a direct replacement with the same catalog number and compatible revision is generally the simplest maintenance approach.
The module provides 16 digital output channels in one compact VersaMax module, supporting multiple field-device control functions.
Its sourcing output configuration is suitable for compatible DC loads that require switched positive voltage.
The IC200MDL740B supports the specified 12/24 V DC operating range, providing flexibility for different industrial control applications.
The specified maximum ON response time of 0.2 ms and OFF response time of 1.0 ms support normal digital control requirements.
Each output point has an LED indicator, allowing maintenance personnel to identify logical output states more easily.
The module connects to a compatible VersaMax carrier base and can be incorporated into modular PLC and distributed I/O systems.
With supplied dimensions of 110 × 66.8 × 50 mm and a weight of 0.231 kg, the module is suitable for compact control cabinet installations.
The IC200MDL740B is a GE Fanuc VersaMax discrete output module with 16 positive-logic DC output points. It is used to control compatible industrial field devices through PLC commands.
It provides 16 discrete output points arranged in one group.
The specified output voltage range is 10.2–30 V DC, with 12/24 V DC nominal operation.
Each output supports a maximum resistive load current of 0.5 A at 30 V DC. The maximum inrush current is 2.0 A for 100 ms.
Yes. An external DC field power supply is required to switch power to connected loads. The VersaMax backplane supplies the module’s internal logic power.
A sourcing output supplies positive voltage to the connected load when activated. A sinking output provides a path toward the DC negative or common side. The field wiring and device configuration must match the output type.
Yes, it can control compatible DC solenoid valve coils when their voltage and current requirements are within the module’s limits. Appropriate suppression should be considered for inductive loads.
The module has an individual LED for each output point. The FLD PWR LED indicates field power, while the OK LED indicates that backplane power is present.
No. The IC200MDL740B does not have internal fuses for individual outputs. External circuit protection should be considered in accordance with the application and electrical design requirements.
Not automatically. Although both are VersaMax positive-logic output modules, the IC200MDL741 includes electronic short-circuit protection. Confirm the required protection, voltage, current, and system configuration before substitution.
When purchasing the GE IC200MDL740B, verify the complete catalog number, hardware revision, physical condition, and compatibility with the existing VersaMax system.
For replacement projects, confirm that the installed carrier base supports the module and that the external field power supply meets the required voltage and current specifications.
For used or refurbished modules, inspect the terminal connections, housing, connector condition, and LED indicators. Where possible, request functional testing of all 16 output points before installation.
During routine maintenance, check field wiring, external power connections, terminal tightness, and the condition of connected loads. Pay particular attention to inductive devices such as relays and solenoid valves, which may generate electrical transients during switching.
Maintain an updated record of PLC output addresses, field terminal assignments, and module configuration. This information can reduce troubleshooting time and simplify future replacement work.
The GE IC200MDL740B VersaMax Discrete Output Module is a 16-point positive-logic digital output module designed for industrial PLC and distributed I/O applications. It supports 12/24 V DC operation, provides up to 0.5 A per output under the specified resistive-load conditions, and includes individual channel status LEDs.
Its compact design and VersaMax system compatibility make it suitable for controlling indicator lamps, relays, solenoid valves, and other compatible DC field devices.
For industrial maintenance and procurement, confirming the hardware revision, external power requirements, output configuration, and carrier compatibility is essential to ensure reliable operation.