Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Emerson CE4005S2B1 KJ3221X1-BA1 + KJ4001X1-CA1 Output Module with Terminal Block is a DeltaV I/O assembly combining an output module with its associated terminal block. It is used to interface control-system output signals with field devices in an industrial process automation environment.
The KJ3221X1-BA1 serves as the output-side I/O hardware, while the KJ4001X1-CA1 provides the corresponding terminal interface. Together, the assembly simplifies the connection between the DeltaV I/O system and external field wiring.
This type of arrangement is useful in process-control cabinets where multiple field outputs must be connected to devices such as control valves, solenoids, contactors, relays, and other actuators. Instead of treating the I/O card and terminal interface as completely separate items during maintenance, the combined assembly provides a more practical replacement and installation unit.
The module is intended for integration into an Emerson DeltaV control architecture, where the controller determines the required output action and the I/O module transfers that command toward the field device.
| Parameter | Specification |
|---|---|
| Manufacturer | Emerson |
| Model | CE4005S2B1 |
| Output Module | KJ3221X1-BA1 |
| Terminal Block | KJ4001X1-CA1 |
| Product Type | Output Module with Terminal Block |
| Automation Platform | Emerson DeltaV |
| Primary Function | Field Output Signal Interface |
| System Role | DeltaV I/O Layer |
| Typical Connected Devices | Valves, solenoids, relays, contactors, actuators |
| Dimensions | 107 × 41 × 105 mm |
| Weight | 0.18 kg |
The supplied physical specifications are 107 × 41 × 105 mm with a stated weight of 0.18 kg. The exact output electrical characteristics and field-device compatibility should be checked against the complete module configuration before installation.
The CE4005S2B1 combines the DeltaV output module and terminal interface into one practical I/O assembly.
Key characteristics include:
The output module should always be selected according to the electrical characteristics of the connected field device. A terminal block may simplify physical wiring, but it does not change the fundamental output requirements of the I/O channel.
The CE4005S2B1 operates at the output interface of a DeltaV control system.
A simplified signal path is:
DeltaV Controller → I/O System → KJ3221X1-BA1 Output Module → KJ4001X1-CA1 Terminal Block → Field Device
The controller executes the configured control strategy and determines when an output should change state or command a connected device.
The output module receives this control information and presents the appropriate output through its channel. The terminal block then provides the practical connection point for field wiring.
For example, a process controller may determine that a valve needs to move to a particular operating condition. The control command is transferred through the DeltaV I/O architecture to the output module, and the corresponding field circuit carries the command toward the actuator or associated control device.
The terminal interface is particularly useful in cabinet environments because it provides an organized transition between the I/O hardware and external field wiring.
The CE4005S2B1 belongs to the I/O layer rather than the controller-processing layer.
A typical architecture can be represented as:
Engineering / Operator Station → DeltaV Controller → I/O Interface → Output Module → Terminal Block → Field Device
The controller handles the control strategy, while the output module performs the electrical interface required to send the control command toward the field.
This separation makes troubleshooting more systematic. If a valve, relay, or solenoid does not respond, the investigation can be divided into the control strategy, controller communication, I/O channel status, terminal connections, field wiring, and the final device itself.
The terminal block also has practical value during maintenance because technicians can inspect and verify field connections without treating the controller and field wiring as one combined circuit.
The CE4005S2B1 can be used wherever DeltaV output channels are required to control external process equipment.
| Application | Typical Output Function |
|---|---|
| Process Control | Sending commands to field actuators |
| Control Valves | Providing output signals for valve control circuits |
| Solenoid Control | Switching or commanding solenoid-operated equipment |
| Motor Control | Interfacing with contactors or relay circuits |
| Chemical Processing | Controlling valves and auxiliary equipment |
| Oil and Gas | Field actuator and process equipment control |
| Water Treatment | Pump, valve, and process equipment commands |
| Power Generation | Auxiliary equipment and process control |
| General Process Automation | Distributed field output control |
The exact application depends on the electrical type and channel characteristics of the installed output module and the connected field device.
The CE4005S2B1 should be installed as part of the appropriate DeltaV I/O architecture. Correct installation involves more than securing the module mechanically; the I/O configuration, terminal connections, field wiring, and connected device must all correspond to the intended control strategy.
Recommended checks include:
When replacing an output assembly, technicians should not assume that a physically similar I/O module has identical electrical behavior. The field device and output channel requirements must be matched before applying a control signal.
The CE4005S2B1 normally works with several components within the DeltaV control system.
| Component | Function |
|---|---|
| DeltaV Controller | Executes the configured control strategy |
| KJ3221X1-BA1 | Provides the output I/O function |
| KJ4001X1-CA1 | Provides the terminal interface for field wiring |
| DeltaV I/O Carrier / Interface | Provides the I/O system connection |
| Control Valve | Receives process-control output commands |
| Solenoid Valve | Performs discrete field actuation |
| Relay | Provides electrical switching or interface |
| Contactor | Controls higher-power circuits through an appropriate interface |
| Field Wiring | Carries output signals to external equipment |
| Engineering Station | Used for configuration and maintenance |
| Operator Station | Provides process monitoring and operator control |
The output assembly should be considered together with the controller, I/O infrastructure, field wiring, and final control device during system design and troubleshooting.
For DeltaV output applications, related Emerson hardware should be selected according to output type, field-device requirements, I/O architecture, and system compatibility.
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Emerson CE4005S2B1 | Output Module with Terminal Block | DeltaV field output interface |
| Emerson KJ3221X1-BA1 | Output Module | DeltaV output signal control |
| Emerson KJ4001X1-CA1 | Terminal Block | DeltaV field wiring termination |
| Emerson DeltaV I/O Modules | I/O Hardware | Field signal interface |
| Emerson DeltaV Controllers | Controller Hardware | Control strategy execution |
| Emerson DeltaV I/O Carriers | I/O Infrastructure | Module installation and system expansion |
The KJ3221X1-BA1 and KJ4001X1-CA1 should be treated as the key hardware combination represented by this assembly. When replacing the complete unit, matching both the I/O module and terminal interface helps avoid incompatibility between the control-system configuration and cabinet wiring.
The terminal block provides the field-wiring interface associated with the output module. It gives technicians a practical termination point between the DeltaV I/O hardware and external field circuits, which is particularly useful in densely wired process-control cabinets.
The electrical requirements of the field device should be compared with the output channel characteristics, including signal type, voltage, current, and required interface arrangement. If the actuator requires an intermediate relay or other interface device, that requirement should be addressed rather than connecting the load directly.
Start at the control strategy and verify that the intended output command is being generated. Then check controller-to-I/O communication, the channel status, terminal connections, field wiring, and finally the actuator or relay. This step-by-step approach helps distinguish a configuration problem from an I/O hardware or field-device fault.
The CE4005S2B1 designation supplied here represents an output module with terminal block, combining the KJ3221X1-BA1 output module and KJ4001X1-CA1 terminal block. For replacement purposes, the complete assembly designation and both associated part numbers should be retained to ensure the cabinet hardware and field termination arrangement remain compatible.