Bently Nevada 3500/93-06-01-02-00 System Display — Product Overview, Technical Specifications, Applications and Related Models 1. Product Introduction The Bently Nevada 3500/93-06-01-02-00 is a configur……
Bently Nevada 3500/93-06-01-02-00 Display Interface I/O Module
  • Bently Nevada
  • 3500/93-06-01-02-00
  • Display Interface I/O Module
  • USA
  • 203.2 × 412.8 × 31.2 mm
  • 2.1kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 2

Our advantage

Bently Nevada 3500/93-06-01-02-00 Display Interface I/O Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Bently Nevada 3500/93-06-01-02-00 Display Interface I/O Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Bently Nevada 3500/93-06-01-02-00 Display Interface I/O Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Bently Nevada 3500/93-06-01-02-00 Display Interface I/O Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Bently Nevada 3500/93-06-01-02-00 System Display — Product Overview, Technical Specifications, Applications and Related Models

1. Product Introduction

The Bently Nevada 3500/93-06-01-02-00 is a configured 3500 System Display designed to provide local or remotely positioned visual access to machinery monitoring and protection information from a compatible 3500 rack. It belongs to the 3500 Machinery Monitoring and Protection System and is intended for industrial installations where operators and maintenance personnel need a dedicated display for reviewing equipment condition, alarm information, and system status.

The 3500/93 is a purpose-built display system rather than a general-purpose computer monitor. It works with the compatible Display Interface Module (DIM), I/O hardware, display unit, and associated rack configuration. Depending on the installed monitoring modules and system configuration, it can present channel measurements, monitor status, relay information, Keyphasor and tachometer data, alarm event lists, and system events.

The key feature of the 3500/93-06-01-02-00 configuration is its back-lighted 19-inch EIA rack-mount arrangement. The backlight improves screen readability in industrial control rooms, equipment rooms, and cabinets where ambient lighting may be limited or variable. The display can be installed in a compatible 19-inch EIA rack, allowing it to be positioned separately from the front of the main 3500 rack when the system layout calls for that arrangement.

The ordering code also specifies a 10-foot (approximately 3-metre) PVC cable, a 230 V AC external power-supply option, and no additional agency approval option. These details are important when planning a replacement or preparing a complete bill of materials. A display unit with a similar family number may use a different mounting arrangement, cable length, power supply, or approval configuration.

The display does not directly measure vibration, shaft position, rotational speed, or other machinery parameters. Those functions are performed by the relevant sensors and monitoring modules installed in the 3500 system. The 3500/93 presents the supported information generated by that equipment, making it easier for operators to inspect system status and respond to reported conditions.

2. Detailed Technical Parameters

The following table summarizes the main characteristics of the specified display configuration. The display unit, Display Interface Module, and Display Interface I/O Module are listed separately because they are distinct physical components.

Parameter Specification
Model 3500/93-06-01-02-00
Brand Bently Nevada
Product name 3500 System Display
Product category Industrial machinery monitoring display system
Product series 3500 Machinery Monitoring and Protection System
Display family 3500/93
Mounting option 06 — back-lighted 19-inch EIA rack mount
Cable option 01 — 10-foot (approximately 3 m) PVC cable
External power-supply option 02 — 230 V AC
Agency approval option 00 — no additional agency approval option specified
Display technology Back-lighted LCD
Display resolution 640 × 200 dots
Display format Text and graphical information
Display function Presents supported machinery monitoring and protection information
Available information Channel, monitor, relay, Keyphasor, tachometer, alarm, and system-event information, subject to rack configuration
Display communication interface RS422 between the display unit and the Display Interface Module
Supported protocol Proprietary display protocol and Modbus protocol, as applicable to the system configuration
Configuration software Compatible 3500 Rack Configuration Software
Display Interface Module dimensions (H × W × D) Approximately 241.3 × 24.4 × 241.8 mm
Display Interface Module weight Approximately 0.82 kg
Display Interface I/O Module dimensions (H × W × D) Approximately 241.3 × 24.4 × 99.1 mm
Display Interface I/O Module weight Approximately 0.38 kg
Display unit dimensions (H × W × D) Approximately 203.2 × 412.8 × 31.2 mm
Display unit weight Approximately 2.1 kg
Main interface module rack requirement One full-height front slot
I/O module rack requirement One full-height rear slot
Display mounting Compatible 19-inch EIA rack
External power input 230 V AC, according to the specified power-supply option
Operating temperature, interface and I/O modules Approximately -30°C to +65°C
Storage temperature, interface and I/O modules Approximately -40°C to +85°C
Relative humidity, interface hardware Up to 95%, non-condensing
Display-unit environmental limits Confirm separately against the applicable display-unit specification
Intended operating mode Continuous display of supported rack monitoring information
Compatibility requirement Compatible 3500 rack, display interface hardware, cable, external power supply, and software configuration

Physical dimensions and weight: The display unit measures approximately 203.2 × 412.8 × 31.2 mm and weighs approximately 2.1 kg. The Display Interface Module measures approximately 241.3 × 24.4 × 241.8 mm and weighs approximately 0.82 kg. The I/O module measures approximately 241.3 × 24.4 × 99.1 mm and weighs approximately 0.38 kg.

These figures describe the individual components, not the complete packaged system. The overall installed and shipping weight will depend on the supplied accessories, external power supply, mounting hardware, cable, and packaging.

3. Product Applications

3.1 Local and Remote Machinery Monitoring

The 3500/93 System Display provides operators with a dedicated interface for reviewing supported monitoring information from a compatible 3500 rack. Depending on the installation, the display can be mounted in a 19-inch EIA rack near the machinery monitoring equipment or at another suitable position within the cable and configuration limits.

This arrangement is useful when operators need access to machinery status without opening separate configuration software for every routine inspection. The back-lighted screen makes it easier to read displayed values in equipment rooms and control cabinets with variable lighting.

3.2 Alarm and Event Review

Machinery monitoring systems can report alarm conditions when measurements reach configured thresholds or when a module detects an abnormal operating state. The 3500/93 can display supported alarm event lists and system events, allowing operators to review reported conditions and identify which parts of the system require attention.

This is particularly useful during start-up, shutdown, load changes, and investigations following an unexpected machinery alarm. The display provides access to information generated by the rack; it does not independently establish the root cause of a fault or replace the protective logic configured in the monitoring system.

3.3 Turbine and Generator Monitoring

Turbines and generators are critical rotating machines used in power generation and other industrial processes. Their condition may be monitored through vibration, shaft position, rotational speed, and other parameters supported by the installed monitoring modules.

The 3500/93 provides a convenient way to view available information from these modules. Operators can use the display during normal operation, start-up checks, maintenance inspections, and alarm investigations.

3.4 Compressor and Pump Applications

Large compressors and pumps are commonly found in oil and gas facilities, chemical plants, power stations, and water-treatment installations. Unplanned equipment problems can affect production, plant availability, and maintenance costs.

When these machines are monitored by a compatible 3500 rack, the 3500/93 can present supported channel values and status information. Maintenance personnel can review the displayed data, identify reported abnormalities, and determine whether additional inspection or diagnostic work is required.

3.5 Oil and Gas Processing Facilities

Oil and gas installations often contain multiple compressor trains, pumps, turbines, and auxiliary machines. A dedicated display can provide local access to the monitoring system without requiring every operator to use an engineering workstation.

The 06 mounting option is intended for a 19-inch EIA rack installation. This can be useful when the display needs to be positioned separately from the front of the main monitoring rack but remain close enough for convenient access.

The included 10-foot PVC cable provides a nominal connection length of approximately 3 metres. The actual installation should be checked against the cable routing, interface requirements, and physical distance between the display and the associated hardware.

3.6 Chemical and Petrochemical Plants

Chemical and petrochemical production relies on rotating equipment for process circulation, compression, cooling, and material transfer. Continuous machinery monitoring helps operations and maintenance teams understand equipment status and respond to abnormal conditions.

The 3500/93 makes supported monitoring information easier to review at a designated display location. It can be incorporated into an existing monitoring arrangement without changing the measurement role of the installed sensors and monitoring modules.

3.7 Power Generation and Utility Equipment

Power plants use turbines, generators, feedwater pumps, cooling-water pumps, fans, and other auxiliary machinery. A dedicated display can support routine operating checks and help technicians review monitoring information during planned maintenance or fault investigations.

The back-lighted screen is useful in control cabinets and equipment rooms where ambient lighting is not always ideal. The 19-inch EIA mounting arrangement also allows the display to be integrated into a compatible rack layout.

3.8 Commissioning and Maintenance

During commissioning, technicians may need to confirm that monitoring channels are functioning, system status is available, and expected alarm information can be viewed. During maintenance, the display can help them check current values and review reported events.

This can reduce the need to access a separate computer for every routine check. Detailed configuration and fault diagnosis may still require compatible software, system documentation, and appropriate test equipment.

3.9 Centralized Machinery Information

In facilities with multiple monitored machines, operators often need to review information from several channels or monitoring functions. The 3500/93 can present supported information from the installed rack modules through a dedicated display interface.

The actual data available depends on the rack configuration and the capabilities of the installed modules. The display should be considered a visual access point to the monitoring system, not a replacement for a plant-wide data historian, SCADA system, or engineering workstation.

4. Main Product Advantages

4.1 Back-Lighted Screen

The back-lighted LCD improves readability in areas where ambient lighting is limited or changes throughout the day. This is useful in machinery rooms, control cabinets, and industrial control areas where operators need to inspect values without relying on external lighting.

The backlight is one of the defining features of the 06 mounting configuration and should be considered when replacing an existing display with a different 3500/93 variant.

4.2 Standard 19-Inch EIA Rack Mounting

The 19-inch EIA mounting arrangement allows the display to be installed in a compatible standard rack. This can simplify integration into an existing equipment cabinet or control-room rack layout.

The mounting configuration differs from the system face-mount, panel-mount, and independent-mount options in the 3500/93 family. Before ordering, the available rack space and required mounting hardware should be checked.

4.3 Specified Cable Included in the Configuration

The 01 cable option specifies a 10-foot PVC cable, approximately 3 metres long. This provides a defined connection length for installations where the display and interface hardware are positioned relatively close together.

Cable routing should account for cabinet layout, bend radius, separation from noisy power conductors, and the interface requirements. If the required distance is longer, a different supported cable configuration may be necessary.

4.4 Dedicated Machinery Monitoring Interface

The 3500/93 is designed specifically for the 3500 monitoring architecture. It provides a defined display interface rather than relying on an unrelated general-purpose monitor.

This is useful for existing 3500 installations because the display is designed to present supported system information through the corresponding interface hardware.

4.5 Access to Alarm and Event Information

The display can present available alarm and system event information. This allows operators to review reported conditions at a dedicated display location and provides useful context during troubleshooting.

A local view of alarm information can be especially helpful when a machinery monitoring rack is installed away from the main control-room workstation.

4.6 Multiple Categories of Monitoring Information

Depending on the installed modules and configuration, the display can show channel values, monitor status, relay information, Keyphasor and tachometer data, and system events.

This helps operators review different aspects of the monitoring system from one interface. The display does not generate these measurements itself; it presents information supplied by compatible rack hardware.

4.7 Integration with an Established Rack Architecture

The 3500/93 is part of a modular monitoring platform. Its display interface, I/O hardware, and display unit work together with the compatible rack configuration.

This modular arrangement helps separate the tasks of measurement, monitoring, protection, data communication, and visual presentation. Each component can therefore be assessed and maintained according to its particular role.

4.8 Practical for Routine Inspections

A dedicated display provides a consistent point of access for operators and maintenance personnel. During routine inspections, technicians can review available values and status information without repeatedly connecting a separate computer.

This can make basic checks more convenient, especially in installations where machinery is monitored continuously and local inspection is part of standard operating procedures.

4.9 Defined External Power Configuration

The 02 option specifies a 230 V AC external power-supply configuration. Identifying this requirement in the ordering code helps engineers plan the required electrical supply and mounting arrangements.

The power supply should be installed according to the applicable instructions and site electrical procedures. The exact supply arrangement should be confirmed before replacing a display with a different ordering configuration.

4.10 Compact Display Unit

The display unit has approximate dimensions of 203.2 × 412.8 × 31.2 mm and a weight of approximately 2.1 kg. This relatively compact form allows it to be installed in a compatible 19-inch rack arrangement without requiring the space occupied by a large industrial workstation.

The overall space requirement still depends on the selected rack, the display mounting hardware, and the location of the Display Interface Module and I/O module.

5. Brand and Product Series

Brand: Bently Nevada

Bently Nevada is associated with industrial machinery condition monitoring and protection equipment. Its product range includes vibration and position monitoring modules, proximity measurement systems, speed-reference modules, relay modules, communication interfaces, display systems, and rack accessories.

These products are used in industrial environments where the condition of rotating machinery must be monitored and the resulting information made available to operators and maintenance personnel.

The 3500/93 is a display product within this portfolio. It provides visual access to supported monitoring information rather than directly measuring vibration, shaft displacement, or rotational speed.

Product Series: 3500 Machinery Monitoring and Protection System

The 3500 series is a modular rack-based platform designed for industrial machinery monitoring and protection. A typical system includes a rack, power supplies, a rack interface, monitoring modules, associated I/O modules, and optional communication, relay, and display hardware.

Each part of the system has a defined role:

– Monitoring modules process supported sensor signals and provide measurement information.

– Rack interface modules provide system-level interface and communication functions.

– Relay modules provide configured discrete outputs.

– Communication gateways transfer supported rack data to compatible external systems.

– Display systems present available information to operators.

The 3500/93 belongs to the display category. It complements the monitoring and protection modules by providing a dedicated visual interface to supported system information.

Position of the 3500/93-06-01-02-00 within the Series

The 3500/93-06-01-02-00 is a back-lighted, 19-inch EIA rack-mount display configuration. It specifies a 10-foot PVC cable and a 230 V AC external power-supply option.

Its function is different from that of a communication gateway such as the 3500/92 or a measurement module such as the 3500/42M. The 3500/93 is primarily intended to present information generated by the monitoring rack.

6. Ordering Code Interpretation

The complete model designation identifies the principal mounting and accessory configuration.

Model segment Interpretation
3500/93 3500 System Display family
06 Back-lighted 19-inch EIA rack-mount configuration
01 10-foot (approximately 3 m) PVC cable
02 230 V AC external power-supply option
00 No additional agency approval option specified

The mounting option is particularly important because the 3500/93 family includes multiple physical arrangements. A back-lighted rack-mount version is not automatically interchangeable with a face-mount, panel-mount, or independent-mount version.

The cable and external power-supply options also affect what must be included in a replacement order. When ordering the display, verify the full configuration, supplied components, and existing installation requirements rather than selecting the part on the basis of the 3500/93 family number alone.

7. Five Related Models in the Same Series or Application

The following models are related to the 3500/93 display family or perform complementary functions within the 3500 monitoring architecture. They may be relevant when replacing a display, changing the mounting arrangement, or expanding an existing rack installation.

Dimensions and weights are approximate component references. The actual figures for an ordered assembly may vary with the hardware revision and accessories supplied.

Dimensions are in millimeters (H × W × D). Weight is in kilograms (kg).

Model Product type Main parameters and function Dimensions Weight (kg)
3500/93-05-00-02-00 Back-lighted System Display System face-mount configuration; 230 V AC external power supply; no separate cable specified Display: approx. 203.2 × 412.8 × 31.2 mm Approx. 2.1 for display unit
3500/93-07-00-02-00 Back-lighted System Display Panel-mount configuration; 230 V AC external power supply Display: approx. 203.2 × 412.8 × 31.2 mm Approx. 2.1 for display unit
3500/93-08-00-02-00 Back-lighted System Display Independent-mount configuration with stainless-steel housing; 230 V AC external power supply Display: approx. 203.2 × 412.8 × 31.2 mm; complete housing dimensions vary Approx. 2.1 for display unit; housing adds weight
135799-02 Display Interface Module Interface module variant associated with the back-lighted display configurations Approx. 241.3 × 24.4 × 241.8 mm Approx. 0.82
135813-01 Display Interface I/O Module Rear I/O module associated with the 3500/93 display system Approx. 241.3 × 24.4 × 99.1 mm Approx. 0.38

7.1 Model 3500/93-05-00-02-00 — Back-Lighted System Face Mount

This configuration is intended for installation over the front of a compatible full-size 3500 rack. It provides a back-lighted display while keeping the display associated with the rack’s front-panel arrangement.

Compared with the specified -06 configuration, the principal difference is the mounting style and cable option. The -05 arrangement should be selected when direct face mounting is required, rather than installation in a separate 19-inch EIA rack.

7.2 Model 3500/93-07-00-02-00 — Back-Lighted Panel Mount

The -07 configuration is designed for panel mounting. It can be appropriate when the display must be integrated into an operator panel or control cabinet rather than placed in a separate rack position.

The panel cutout, mounting hardware, and power requirements should be confirmed before installation. The physical dimensions of the display unit alone do not define the required panel opening.

7.3 Model 3500/93-08-00-02-00 — Back-Lighted Independent Mount

The -08 configuration is intended for independent mounting and uses a stainless-steel housing. It can be useful when the display needs to be positioned separately from the main 3500 rack.

This arrangement provides more freedom in selecting the display location, but the complete installation must account for the housing, mounting hardware, cable routing, and power supply. The weight of the complete assembly will exceed the display-unit weight alone.

7.4 Model 135799-02 — Display Interface Module

The 135799-02 is an interface-module variant associated with designated 3500/93 back-lighted display configurations. It forms part of the interface arrangement between the monitoring rack and the display unit.

This component is relevant when servicing the display interface hardware rather than replacing the screen itself. Compatibility should be checked against the existing module, display configuration, and rack arrangement before substitution.

7.5 Model 135813-01 — Display Interface I/O Module

The 135813-01 is the Display Interface I/O Module used in the 3500/93 system. It provides the rear I/O connection required by the relevant display configuration.

Its approximate dimensions are 241.3 × 24.4 × 99.1 mm, and its approximate weight is 0.38 kg. It is a separate component from both the Display Interface Module and the display unit, so the three should not be treated as interchangeable replacement parts.

8. Five Popular Models from the Same Brand

The following models represent other commonly used parts of the Bently Nevada machinery monitoring portfolio. They perform measurement, rotational reference, relay, communication, and power functions that may complement a 3500/93 display installation.

They are related to the same monitoring ecosystem, but they are not direct replacements for the display system.

Dimensions and weights for rack modules are approximate main-board references. Separate I/O modules, connectors, or accessories may add to the final installed weight.

Model Product type Main technical parameters and function Dimensions (H × W × D) Weight (kg)
3500/42M Proximitor Seismic Monitor Four-channel monitoring module family for supported vibration and position measurements Approx. 241.3 × 24.4 × 241.8 mm for main board Approx. 0.82 for main board
3500/45 Position Monitor Supports configured position-monitoring applications, depending on version and input configuration Approx. 241.3 × 24.4 × 241.8 mm for main board Approx. 0.82 for main board
3500/25 Keyphasor Module Processes rotational reference signals used for speed- and phase-related monitoring Approx. 241.3 × 24.4 × 241.8 mm for main board Approx. 0.82 for main board
3500/32M Four-Channel Relay Module Four configured relay channels for designated alarm and status conditions Approx. 241.3 × 24.4 × 241.8 mm for main board Approx. 0.82 for main board
3500/92 Communication Gateway Module Transfers supported rack data to compatible external systems using the selected communication configuration Main board: approx. 241.3 × 24.4 × 241.8 mm Approx. 0.82 for main board

8.1 Model 3500/42M — Proximitor Seismic Monitor

The 3500/42M is used for supported vibration and position monitoring applications. It processes signals from compatible sensors and supplies monitoring information to the wider 3500 system.

It is useful in applications where machinery vibration or shaft displacement needs to be monitored continuously. The 3500/93 can provide a visual interface for supported data generated by this and other compatible monitoring modules.

8.2 Model 3500/45 — Position Monitor

The 3500/45 supports position-monitoring functions according to its version and configuration. Applications can include differential expansion and other supported machinery position measurements.

Position measurements are important on large rotating machines where shaft and casing movement must be assessed against configured operating limits. The monitor performs the measurement-monitoring function, while the 3500/93 provides a way to view available information.

8.3 Model 3500/25 — Keyphasor Module

The 3500/25 processes rotational reference signals used for speed- and phase-related monitoring. Such signals help the monitoring system relate measurements to shaft rotation.

This module is useful where a rotational reference is required for the monitoring application. It complements the display system but does not perform a display function itself.

8.4 Model 3500/32M — Four-Channel Relay Module

The 3500/32M provides four relay channels that can be configured to respond to designated system conditions. These outputs can be used to interface configured alarms or status information with external equipment.

The module provides discrete outputs, whereas the 3500/93 provides visual presentation. They therefore serve different but complementary roles within the overall monitoring system.

8.5 Model 3500/92 — Communication Gateway Module

The 3500/92 provides a communication path for supported monitoring values and status information from the 3500 rack to compatible external systems. The exact interfaces and protocols depend on the selected hardware configuration.

It is relevant when monitoring information needs to be integrated into a plant control or data-acquisition system. The 3500/92 transfers data, while the 3500/93 presents supported information on a dedicated display.

9. Comparison of the Main 3500/93 Display Configurations

Feature 3500/93-06-01-02-00 3500/93-05-00-02-00 3500/93-07-00-02-00 3500/93-08-00-02-00
Display type Back-lighted LCD Back-lighted LCD Back-lighted LCD Back-lighted LCD
Mounting method 19-inch EIA rack mount System face mount Panel mount Independent mount
Cable option 10-foot PVC cable No separate cable specified No separate cable specified No separate cable specified
External power option 230 V AC 230 V AC 230 V AC 230 V AC
Typical installation Separate rack position Directly over compatible rack front Control panel Separate housing or location
Main selection consideration Rack space, cable length, power Rack-front mounting Panel cutout and mounting hardware Housing and mounting arrangement

These configurations share the same general purpose, but their mounting styles and accessory requirements differ. The -06 configuration is intended for a separate 19-inch EIA rack position, while the -05, -07, and -08 options serve face-mount, panel-mount, and independent-mount installations, respectively.

10. Installation and Maintenance Considerations

10.1 Verify the Rack and Mounting Arrangement

Before installation, confirm that the intended location supports a 19-inch EIA rack-mount display. Check the available rack space and ensure that the display, interface module, and associated I/O hardware can be installed in their required positions.

A face-mount or panel-mount display should not be substituted solely because it belongs to the same 3500/93 family. The physical mounting arrangement must match the application.

10.2 Confirm the 230 V AC Power Supply

The 02 option specifies a 230 V AC external power-supply configuration. Confirm the available supply, the applicable electrical requirements, and the correct installation method before connecting the display.

Do not assume that a display with a similar part number uses the same external power arrangement. Back-lighted and non-backlighted configurations can differ in their power requirements.

10.3 Check the Cable Length and Type

The 01 option specifies a 10-foot PVC cable, approximately 3 metres long. Confirm that the included cable suits the distance between the display and the interface hardware.

If the installed arrangement requires a longer connection, select an appropriate supported cable option. Do not assume that an extension or alternative cable will work correctly without checking the applicable interface requirements.

10.4 Verify the Display Interface and I/O Modules

The Display Interface Module and Display Interface I/O Module are separate components. Confirm the installed part numbers and their compatibility with the selected display configuration.

If the screen does not operate correctly, the problem may involve the display unit, interface module, I/O module, cable, power supply, or configuration. Replacing the display unit alone may not resolve a fault originating elsewhere.

10.5 Verify System Configuration

After installation, confirm that the display communicates with the compatible 3500 system and that the expected monitoring values and status information appear.

Check the display interface status, rack module status, cable connection, and configuration software where necessary. Alarm and event information should be checked against the actual system state before the display is returned to service.

10.6 Consider Environmental Conditions

Ensure that the display and interface hardware are installed within their respective environmental limits. Temperature, humidity, electrical noise, grounding, and cabinet ventilation should be considered as part of the complete installation.

The display-unit environmental limits may differ from those of the interface and I/O modules, so each component should be evaluated separately.

10.7 Follow Safe Replacement Procedures

Follow the applicable site procedures before removing or replacing any component. Determine whether the work affects the availability of monitoring information or required operator access.

A display-interface problem does not necessarily mean that the rack has stopped processing sensor signals. However, the actual state of the monitoring system must be confirmed through the rack’s indicators and appropriate diagnostic procedures.

11. Summary

The Bently Nevada 3500/93-06-01-02-00 System Display is a back-lighted, 19-inch EIA rack-mount display configuration designed to provide visual access to supported information from a compatible 3500 machinery monitoring and protection rack.

Its principal features are the back-lighted LCD, 19-inch EIA rack mounting, a specified 10-foot PVC cable, and a 230 V AC external power-supply option. These features make it suitable for industrial installations where a dedicated display is needed near the monitoring rack or within a compatible control-room cabinet.

The display unit itself measures approximately 203.2 × 412.8 × 31.2 mm and weighs approximately 2.1 kg. The associated Display Interface Module measures approximately 241.3 × 24.4 × 241.8 mm and weighs approximately 0.82 kg, while the I/O module measures approximately 241.3 × 24.4 × 99.1 mm and weighs approximately 0.38 kg.

For purchasing and replacement, the most important details to verify are the complete ordering code, mounting configuration, cable length and type, external power-supply requirement, and compatibility of the Display Interface Module and I/O hardware. Matching these details helps ensure that the selected configuration fits the existing installation and provides the intended display function.