| +8615980777398 | |||
| 15980777398 |

The Allen Bradley 440R-B23020 Guardmaster Minotaur MSR5T Safety Relay is an industrial safety monitoring relay designed to supervise safety-related control circuits in machinery. It can be connected to emergency-stop push buttons, safety gate switches, and other compatible safety devices to help control hazardous machine operation.
Operating with a 24V AC/DC power supply, the MSR5T provides three normally open (NO) safety outputs and one normally closed (NC) auxiliary output. Its internal monitoring functions support safety circuit operation and external contactor monitoring through a feedback loop. The relay also supports automatic and manual reset configurations, allowing it to be integrated into different machine-control arrangements.
With a compact 22.5 mm housing and 35 mm DIN rail mounting, the 440R-B23020 is suitable for installation inside industrial electrical control cabinets. It is commonly used in applications where a dedicated safety relay is required to monitor emergency-stop or guard-interlock circuits.
| Parameter | Specification |
|---|---|
| Brand | Allen Bradley |
| Product Family | Guardmaster Minotaur |
| Model Number | 440R-B23020 |
| Relay Model | MSR5T |
| Product Type | Monitoring Safety Relay |
| Supply Voltage | 24V AC/DC |
| Supply Frequency | 50/60 Hz |
| Safety Inputs | 1 Normally Closed (NC) |
| Safety Outputs | 3 Normally Open (NO) |
| Auxiliary Output | 1 Normally Closed (NC) |
| Reset Configuration | Automatic or Manual Monitored Reset |
| Feedback Monitoring | External contactor monitoring |
| Response Time | 30 ms |
| Power Consumption | 2 W |
| Mounting | 35 mm DIN Rail |
| Housing Width | 22.5 mm |
| Housing Protection | IP40, NEMA 1 |
| Terminal Protection | IP20 |
| Operating Temperature | -5°C to +55°C |
| Dimensions | 114.5 × 22.5 × 99 mm |
| Weight | 0.18 kg |
The 440R-B23020 is designed to receive a normally closed safety input from a compatible emergency-stop device or guard interlock. Under normal operating conditions, the input circuit remains closed, allowing the relay to proceed through its activation sequence.
When the safety device is operated, the input circuit opens and the relay deactivates its safety outputs. This interrupts the control signals supplied to the downstream machine-control components.
The MSR5T is a single-channel input safety relay. Its suitability for a particular machine must therefore be determined through a risk assessment and the required safety architecture rather than assuming that it supports every dual-channel safety application.
The relay provides three normally open safety output contacts:
When the required input and reset conditions are satisfied, these contacts close and enable the connected safety-related control circuits.
The three outputs can be used in suitable control arrangements involving contactors, machine enable circuits, or other compatible equipment. Their application must follow the relay’s contact ratings and the machine’s safety design.
In addition to its three safety outputs, the MSR5T provides one normally closed auxiliary contact, identified by terminals 41–42.
This contact is intended for control indication and status monitoring. It can provide information to an external control system, such as a PLC, where appropriate.
The auxiliary contact is not a safety output and must not be used as a substitute for the dedicated safety contacts.
The 440R-B23020 supports automatic and manual monitored reset configurations.
Automatic reset allows the relay to become operational when the required input and feedback conditions are satisfied. Manual monitored reset requires an appropriate reset action through the configured circuit.
The reset arrangement should be selected according to the machine’s safety requirements. Automatic reset must not create an unexpected machine restart or allow hazardous movement without the required operator safeguards.
The MSR5T can monitor external contactors through its feedback circuit, connected using terminals X1 and X2.
Normally closed auxiliary contacts from the monitored contactors or expansion devices can be incorporated into this feedback loop. This allows the relay to check whether the external switching devices have returned to their expected resting condition before another reset sequence is accepted.
This function is important in applications where welded or mechanically stuck contactor contacts could affect the machine’s safe operation.
The Allen Bradley 440R-B23020 is used in industrial control cabinets where emergency-stop or guard-interlock signals need to be monitored by a dedicated safety relay.
Common application areas include:
The relay should only be used in applications where its input configuration, output ratings, and safety characteristics are appropriate for the machine.
Correct installation is essential for reliable safety relay operation. The 440R-B23020 should be installed by qualified personnel familiar with industrial electrical systems and functional safety requirements.
The MSR5T is designed for mounting on a standard 35 mm DIN rail. Install the relay securely inside an electrical enclosure with adequate space for wiring and maintenance.
The relay itself has an IP40 housing and IP20 terminal protection. Rockwell Automation specifies installation inside an enclosure with a minimum IP54 rating.
The relay requires a 24V AC/DC supply connected to terminals A1 and A2.
Confirm the supply voltage and polarity where applicable before energizing the device. The specified operating supply range is 0.85–1.1 times the rated voltage.
An external 2 A, 600V AC fast-acting fuse is specified for the input power circuit. Use the fuse type and installation arrangement recommended in the manufacturer’s instructions.
Connect the compatible normally closed safety device to the designated input circuit.
Typical devices include emergency-stop push buttons and suitable guard interlock switches. Check the exact wiring diagram before connecting the field device, as incorrect wiring can prevent the relay from operating correctly.
Connect terminals 13–14, 23–24, and 33–34 to the intended downstream control circuits.
The output contacts should be used within their specified electrical ratings. Appropriate external protection must be provided according to the connected load and applicable electrical design requirements.
Use terminals X1 and X2 for the reset and external feedback arrangement.
For monitored contactor applications, connect the relevant normally closed auxiliary contacts in the feedback loop as specified in the wiring instructions. Select automatic or manual monitored reset according to the machine’s risk assessment and restart requirements.
After completing the wiring, inspect all connections and perform a controlled functional test.
Verify that the relay responds correctly when the safety input opens, that the safety outputs return to their expected states, and that the reset and feedback functions operate as designed.
The complete safety function must be validated as part of the machine commissioning process. Testing only the relay does not establish the safety performance of the entire machine.
Periodic inspection helps maintain reliable operation and identify wiring or component problems before they cause unexpected downtime.
| Symptom | Possible Cause | Recommended Action |
|---|---|---|
| Power indicator is off | Missing 24V AC/DC supply or blown fuse | Check A1–A2 voltage and the external input fuse |
| Safety outputs do not close | Safety input circuit is open | Inspect the emergency-stop device and input wiring |
| Relay does not reset | Incorrect reset wiring or feedback circuit open | Check X1–X2 and the monitored contactor contacts |
| Relay drops out during operation | Intermittent safety input or loose wiring | Inspect field devices, terminal connections, and cables |
| External contactors do not operate | Incorrect output wiring or downstream control fault | Check safety output contacts and contactor control circuits |
| Unexpected reset behavior | Incorrect automatic or manual reset configuration | Review reset wiring and machine control logic |
| Auxiliary signal is incorrect | Wiring error or auxiliary contact problem | Check terminals 41–42 and the connected monitoring circuit |
| Relay operates intermittently | Electrical interference, vibration, or unstable supply | Check supply quality, mounting, and wiring conditions |
The relay should not be dismantled or repaired in the field. Rockwell Automation’s installation instructions specify replacing the unit if it is malfunctioning or damaged. Never bypass the safety input or bridge the output contacts to keep a machine running.
1. What is the Allen Bradley 440R-B23020?
It is a Guardmaster Minotaur MSR5T monitoring safety relay designed to supervise compatible emergency-stop and safety gate circuits in industrial machinery.
2. What voltage does the MSR5T require?
The relay operates with a nominal 24V AC/DC supply at 50/60 Hz.
3. How many safety outputs does the 440R-B23020 provide?
It provides three normally open safety outputs, connected through terminals 13–14, 23–24, and 33–34.
4. Does this model have an auxiliary output?
Yes. It has one normally closed auxiliary output at terminals 41–42. This contact is intended for control indication and is not a safety output.
5. What types of safety devices can be connected?
The MSR5T can be used with compatible emergency-stop push buttons and safety gate switches that provide the required normally closed input arrangement.
6. Does the relay support manual reset?
Yes. It supports automatic reset and manual monitored reset configurations. The appropriate arrangement depends on the machine’s safety design.
7. Can the MSR5T monitor external contactors?
Yes. Its feedback circuit can monitor external contactors through their normally closed auxiliary contacts, helping verify that the switching devices have returned to their expected resting condition.
8. What is the mounting method?
The relay is designed for 35 mm DIN rail mounting inside a suitable electrical enclosure.
9. What should be checked if the relay fails to reset?
Inspect the safety input circuit, reset wiring, 24V AC/DC supply, and external contactor feedback loop. An open feedback circuit can prevent the relay from completing its reset sequence.
10. Can the 440R-B23020 replace another Guardmaster safety relay?
Not necessarily. Check the input configuration, number and type of safety outputs, auxiliary contact arrangement, supply voltage, reset method, response time, and safety requirements before selecting a replacement.
The Allen Bradley 440R-B23020 Guardmaster Minotaur MSR5T is a compact monitoring safety relay designed for industrial emergency-stop and guard-interlock applications. Its 24V AC/DC supply, three normally open safety outputs, normally closed auxiliary contact, and external contactor monitoring capability make it suitable for a range of machine safety control arrangements.
For replacement and maintenance projects, verifying the exact model number and wiring configuration is essential. Proper installation, monitored reset configuration, and functional testing help ensure that the relay operates correctly as part of the complete machine safety system.