The Allen-Bradley 20G1ALE395JN0NNNNN is a high-power industrial AC variable frequency drive belonging to the PowerFlex 755 series.
It is designed for large three-phase AC motor applications where accurate speed control, adjustable acceleration and deceleration, high output current, network communication, and reliable industrial operation are required.
This model is configured for 600 VAC three-phase power, uses a Frame 8 power structure, and provides a maximum Light Duty output-current rating of 395 A.
Depending on the operating duty, the drive is rated for approximately 450 HP in Light Duty, 400 HP in Normal Duty, and 350 HP in Heavy Duty applications. The actual application rating should be selected according to motor nameplate current, load characteristics, acceleration requirements, ambient conditions, and the required overload profile.
The drive uses forced-air cooling and a Type 1 / IP20, 800 mm deep MCC-style construction.
It includes embedded EtherNet/IP communication, allowing the drive to be integrated into a networked industrial control system.
The stated configuration uses an AC input with precharge and no DC terminals, has no dynamic braking, includes filtering, has the CM jumper installed, and is supplied as a blank / no HIM configuration.
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Product Family | PowerFlex |
| Product Series | PowerFlex 755 |
| Model | 20G1ALE395JN0NNNNN |
| Product Type | Industrial AC Variable Frequency Drive |
| Drive Category | High-Power AC Drive |
| Voltage Class | 600 VAC |
| Phase | Three Phase |
| Frame | Frame 8 |
| Cooling | Forced Air |
| Communication | Embedded EtherNet/IP |
| Enclosure | Type 1 / IP20 |
| Cabinet Style | 800 mm Deep MCC Style |
| Input Type | AC Input with Precharge |
| External DC Terminals | None |
| Dynamic Braking | None |
| Filtering | Filtered |
| CM Jumper | Installed |
| HIM | Blank / No HIM |
The PowerFlex 755 series is positioned for applications that require more than basic variable-speed operation.
The platform is intended for larger industrial machinery where motor speed, torque, acceleration, diagnostics, communications, and process coordination are important.
| Parameter | 20G1ALE395JN0NNNNN Specification |
|---|---|
| Model | 20G1ALE395JN0NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product Type | AC Variable Frequency Drive |
| Input Voltage | 600 VAC |
| Input Phase | 3 Phase |
| Frame Size | Frame 8 |
| Maximum LD Output Current | 395 A |
| ND Output Current | 355 A |
| HD Output Current | 295 A |
| LD Motor Rating | 450 HP |
| ND Motor Rating | 400 HP |
| HD Motor Rating | 350 HP |
| Cooling | Forced Air |
| Enclosure | Type 1 / IP20 |
| Cabinet Depth | 800 mm class |
| Cabinet Style | MCC Style |
| Communication | Embedded EtherNet/IP |
| Input Configuration | AC Input with Precharge |
| External DC Terminals | None |
| Dynamic Braking | None |
| Filtering | Filtered |
| CM Jumper | Installed |
| HIM | Blank / No HIM |
| Main Application | Large industrial AC motors |
| Typical Loads | Pumps, fans, conveyors, compressors, process machinery |
| Installation | Industrial cabinet / MCC |
| Approx. Unit Weight Reference | Approximately 84 kg for the referenced listed unit |
| Physical Dimensions | Large Frame 8 / MCC-style configuration; final dimensions depend on the complete mechanical arrangement |
The current and horsepower ratings above correspond to the specified 20G1ALE395 configuration.
The 20G1ALE395JN0NNNNN is a multi-duty industrial drive.
Its published ratings allow it to be applied to different load categories.
| Duty | Continuous Output Current | Short-Time Overload | Approx. Motor Rating |
|---|---|---|---|
| Light Duty | 395 A | 435 A / 1 min | 450 HP |
| Normal Duty | 355 A | 391 A / 1 min; higher short-time overload capability | 400 HP |
| Heavy Duty | 295 A | 443 A / 1 min; higher short-time overload capability | 350 HP |
The distinction between LD, ND, and HD is important.
A drive should not simply be selected according to the highest horsepower number shown in a product description.
The motor’s actual full-load current, required overload capability, starting torque, acceleration profile, operating cycle, and load characteristics should be checked before final selection.
In Light Duty operation, the drive provides its highest continuous current rating.
For this model, the Light Duty rating is:
395 A continuous output current
with an approximate motor rating of:
450 HP
Light Duty operation is generally appropriate for applications with relatively moderate overload requirements and smoother torque characteristics.
Typical examples can include large centrifugal pumps, large fans, and certain blower applications.
The Normal Duty rating is approximately:
355 A continuous output current
with an approximate motor rating of:
400 HP
Normal Duty operation provides a different balance between motor power and overload capability.
This rating can be relevant to general industrial machinery where the load is more demanding than a typical variable-torque application but does not require the highest Heavy Duty operating profile.
The Heavy Duty rating is approximately:
295 A continuous output current
with an approximate motor rating of:
350 HP
Heavy Duty operation is intended for applications where higher torque demand and overload performance are important.
Examples can include certain conveyors, heavy process machinery, mixers, material-handling equipment, and machinery with demanding acceleration requirements.
The 20G1ALE395JN0NNNNN is designed for a 600 VAC three-phase input.
| Input Parameter | Specification |
|---|---|
| Input Voltage | 600 VAC |
| Phase | 3 Phase |
| Input Type | AC |
| Precharge | Included |
| DC Input Terminals | None |
| Voltage Class | 600 VAC |
| Input Filtering | Filtered |
| Industrial Frequency | 50/60 Hz class |
| Application | High-power industrial motor systems |
The input precharge arrangement is important for high-power equipment because the drive contains a substantial DC bus energy-storage section.
During startup, the precharge system helps control the charging process of the DC bus.
The drive converts the fixed incoming AC supply into a controlled variable-frequency AC output.
This allows the connected motor to operate at different speeds according to the process requirement.
| Output Parameter | Specification |
|---|---|
| Output Type | Variable-frequency AC |
| Motor Type | Three-phase AC motor |
| Maximum LD Current | 395 A |
| ND Current | 355 A |
| HD Current | 295 A |
| LD Motor Rating | 450 HP |
| ND Motor Rating | 400 HP |
| HD Motor Rating | 350 HP |
| Speed Control | Yes |
| Acceleration Control | Yes |
| Deceleration Control | Yes |
| Torque Control | Supported |
| Network Control | Supported |
The PowerFlex 755 is a high-performance industrial drive platform designed for large motor-driven machinery.
The 20G1ALE395JN0NNNNN combines a high-current power section with embedded industrial network communication.
Instead of operating a large motor directly from a fixed-frequency AC supply, the drive can regulate the motor’s operating speed according to the needs of the machine.
This is useful in applications where process demand changes during operation.
For example, a large pump may not need to run at full speed continuously.
A large fan may need different airflow at different production conditions.
A conveyor may require controlled acceleration rather than an immediate full-speed start.
A process machine may need a specific speed profile during different stages of operation.
The PowerFlex 755 platform is intended to handle these types of requirements.
The fundamental function of the drive is to provide adjustable-speed operation for a three-phase AC motor.
Motor speed can be changed by controlling the output frequency and voltage.
This allows the mechanical equipment to operate according to the actual production or process requirements.
The drive can provide programmed acceleration instead of connecting the motor directly to full line power.
This can help reduce mechanical shock and provide smoother machine startup.
The drive can also provide controlled deceleration.
This is useful for conveyors, process machinery, fans, pumps, and other systems where an uncontrolled stop may cause mechanical or process problems.
The PowerFlex 755 platform supports motor-control functions suitable for applications requiring controlled torque.
This is useful where the load changes during operation.
The embedded EtherNet/IP interface allows the drive to be integrated into an industrial automation network.
This can allow commands, references, status information, and diagnostic information to be exchanged between the drive and the control system.
The 20G1ALE395JN0NNNNN includes embedded EtherNet/IP communication.
This is one of the most useful characteristics of this configuration for modern industrial automation systems.
A typical system can be arranged as:
PLC → EtherNet/IP Network → PowerFlex 755 → AC Motor → Mechanical Load
The drive can exchange operating information with the control system.
Typical network information can include:
| Data Type | Typical Function |
|---|---|
| Start Command | Starts motor operation |
| Stop Command | Stops motor operation |
| Speed Reference | Sets required speed |
| Frequency Reference | Sets output frequency |
| Output Frequency | Reports actual operating frequency |
| Output Current | Reports motor current |
| Drive Status | Reports operating condition |
| Fault Status | Reports faults |
| Alarm Status | Reports warnings |
| Control Word | Sends operating commands |
| Status Word | Returns drive status |
| Diagnostic Information | Supports troubleshooting |
This makes the drive particularly useful in automated production environments.
A key difference between the 20G1ALE395JN0NNNNN and the closely related 20G1ALE395AN0NNNNN is the CM jumper configuration.
For the J configuration, the CM jumper is specified as:
CM Jumper Installed — Preferred
The complete configuration information identifies the unit as filtered with the CM jumper installed.
This detail should not be ignored when replacing an existing drive.
Two drives can have almost identical current and horsepower ratings but still have different electrical configurations.
For replacement work, the complete catalog number should therefore be checked rather than matching only the series and amp rating.
| Parameter | 20G1ALE395JN0NNNNN | 20G1ALE395AN0NNNNN |
|---|---|---|
| Series | PowerFlex 755 | PowerFlex 755 |
| Voltage | 600 VAC | 600 VAC |
| Frame | 8 | 8 |
| LD Current | 395 A | 395 A |
| LD Motor Rating | 450 HP | 450 HP |
| ND Motor Rating | 400 HP | 400 HP |
| HD Motor Rating | 350 HP | 350 HP |
| Cooling | Forced Air | Forced Air |
| Enclosure | Type 1 / IP20 | Type 1 / IP20 |
| EtherNet/IP | Embedded | Embedded |
| Dynamic Braking | None | None |
| Input | AC with Precharge | AC with Precharge |
| DC Terminals | None | None |
| Filtering | Filtered | Filtered |
| CM Jumper | Installed | Removed |
| HIM | Blank / No HIM | Blank / No HIM |
The most obvious configuration distinction is the CM jumper.
The J version is configured with the jumper installed, while the A version is configured differently.
This can matter in system grounding, EMC, replacement, and electrical compatibility considerations.
The 20G1ALE395JN0NNNNN is suitable for large industrial motor applications.
Typical application areas include:
Large pumps frequently require variable-speed control.
The drive can adjust motor speed according to process requirements rather than operating continuously at a fixed speed.
Potential applications include:
| Pump Type | Typical Use |
|---|---|
| Water Pump | Water transfer |
| Booster Pump | Pressure control |
| Cooling Pump | Cooling-water circulation |
| Process Pump | Industrial process control |
| Wastewater Pump | Wastewater handling |
| Circulation Pump | Process circulation |
| Transfer Pump | Liquid transfer |
| Industrial Pump | General process service |
For pump applications, the actual control strategy can be based on pressure, flow, level, temperature, or another process variable.
Large fans and blowers often have changing airflow requirements.
A variable frequency drive can adjust motor speed according to the required airflow.
Typical applications include:
The drive can provide controlled startup and adjustable running speed.
Conveyors can have significant mechanical inertia and load torque.
Starting a heavily loaded conveyor directly across the line can produce high starting current and mechanical shock.
A variable frequency drive allows the motor to accelerate according to a programmed profile.
Typical applications include:
The drive can also be integrated into a larger control system so that conveyor speed can be coordinated with other equipment.
Large compressors can require substantial motor power and controlled acceleration.
The PowerFlex 755 platform can be considered for compressor applications where variable-speed operation is required.
Potential applications include:
Compressor applications require careful evaluation of minimum speed, acceleration time, torque requirements, motor cooling, and process control.
The 395 A Light Duty rating places this model in a high-power industrial drive class.
It is intended for large motors rather than small general-purpose machinery.
The 600 VAC voltage class allows the drive to be used with large industrial motor systems designed for this voltage level.
The LD, ND, and HD ratings allow the drive to be considered for different load characteristics.
Integrated EtherNet/IP communication allows the drive to participate directly in a networked automation architecture.
The Frame 8 design is intended for large drive applications where substantial power capacity is required.
Forced-air cooling provides the thermal management required by a high-power drive.
The 800 mm deep MCC-style configuration is suitable for centralized industrial electrical installations.
Drive status and fault information can be integrated into a plant control system.
The same PowerFlex 755 platform can be applied to pumps, fans, conveyors, compressors, and other industrial machinery.
The drive provides adjustable speed and acceleration/deceleration control rather than fixed-speed motor operation.
The model is a large Frame 8, 800 mm deep MCC-style drive configuration.
For this type of equipment, physical dimensions can depend on the complete cabinet arrangement, installation configuration, and associated components.
The available product information identifies the enclosure as Type 1 / IP20 with an 800 mm deep MCC-style construction.
For weight, a listed unit reference gives approximately 185 lb, which is about 84 kg. This figure should be treated as a product/unit reference rather than a guaranteed shipping weight for every complete cabinet arrangement.
| Physical Parameter | Specification / Reference |
|---|---|
| Model | 20G1ALE395JN0NNNNN |
| Frame | Frame 8 |
| Enclosure | Type 1 / IP20 |
| Cabinet Style | MCC Style |
| Cabinet Depth | 800 mm |
| Approx. Unit Weight | 84 kg |
| Weight Reference | Approximately 185 lb |
| Overall Dimensions | Large Frame 8 MCC-style arrangement |
| Installation | Vertical industrial cabinet / MCC |
| Cooling | Forced Air |
| Service Space | Required according to installation design |
For cabinet fabrication, transportation, lifting, foundation design, or final mechanical engineering, the exact mechanical drawing for the configured unit should be used.
The 800 mm depth is a particularly important consideration when planning the electrical room or MCC lineup.
A high-power drive such as the 20G1ALE395JN0NNNNN requires careful installation planning.
Important considerations include:
The drive should be installed in a suitable industrial electrical environment.
Because the enclosure is Type 1 / IP20, the equipment should not be treated as a weatherproof or washdown enclosure.
The 20G1ALE395JN0NNNNN uses forced-air cooling.
At this power level, heat management becomes an important part of system design.
The actual heat generated depends on:
The cabinet should provide adequate airflow and should avoid recirculating hot exhaust air back into the cooling inlet.
Air filters and cooling fans should also be included in the maintenance plan.
Regular maintenance can include inspection of:
The forced-air cooling system is particularly important.
Dust accumulation around air filters or cooling passages can reduce airflow and increase operating temperature.
For large industrial drives, planned inspection is preferable to waiting for a cooling-related fault.
The integrated EtherNet/IP interface provides several practical benefits in an automated system.
The drive can be connected to the plant network and controlled from a central automation system.
A typical architecture may include:
Operator HMI → PLC → Industrial Ethernet Network → PowerFlex 755 → Motor
This architecture allows motor operation to become part of the overall machine-control strategy.
For example, the PLC can determine the required motor speed based on process conditions, send the reference to the drive, and monitor drive status.
The operator can then view drive information through the HMI.
The model is particularly useful when motor speed is part of the process itself.
Examples include:
Pump speed can be adjusted according to required flow.
Pump speed can be changed according to system pressure.
Fan speed can be adjusted according to ventilation demand.
Conveyor speed can be coordinated with production requirements.
Motor speed can be adjusted according to different stages of a manufacturing process.
The following five models are useful comparison points within the same PowerFlex 755 high-power family.
| Model | Series | Voltage | Current Class | LD Rating | ND Rating | HD Rating |
|---|---|---|---|---|---|---|
| 20G1ALE355AN0NNNNN | PowerFlex 755 | 600 VAC | 355 A class | 400 HP | 350 HP | 300 HP |
| 20G1ALE395JN0NNNNN | PowerFlex 755 | 600 VAC | 395 A | 450 HP | 400 HP | 350 HP |
| 20G1ALE435JN0NNNNN | PowerFlex 755 | 600 VAC | 435 A | 500 HP | 450 HP | 350 HP |
| 20G1ALE460JN0NNNNN | PowerFlex 755 | 600 VAC | 460 A | 500 HP | 500 HP | 400 HP |
| 20G1ALE510JN0NNNNN | PowerFlex 755 | 600 VAC | 510 A class | Higher-power class | Higher-power class | Higher-power class |
For the neighboring 355 A, 435 A, and 460 A catalog families, published product listings identify the corresponding power classes; exact suffix configuration should still be checked before ordering.
| Parameter | 20G1ALE355AN0NNNNN | 20G1ALE395JN0NNNNN | 20G1ALE435JN0NNNNN | 20G1ALE460JN0NNNNN | 20G1ALE510JN0NNNNN |
|---|---|---|---|---|---|
| Series | PF755 | PF755 | PF755 | PF755 | PF755 |
| Voltage | 600 VAC | 600 VAC | 600 VAC | 600 VAC | 600 VAC |
| Current Class | 355 A | 395 A | 435 A | 460 A | 510 A class |
| Frame | 8 | 8 | 8 | 8 | 8-class |
| LD | 400 HP | 450 HP | 500 HP | 500 HP | Higher-power |
| ND | 350 HP | 400 HP | 450 HP | 500 HP | Higher-power |
| HD | 300 HP | 350 HP | 350 HP | 400 HP | Higher-power |
| Cooling | Forced Air | Forced Air | Forced Air | Forced Air | Forced Air |
| Typical Use | Pumps / Fans | Large Motors | Process Machinery | Heavy Industrial Loads | Very Large Loads |
For comparison across the same Allen-Bradley variable-frequency-drive product family, the following models provide useful reference points.
| Model | Series | Approx. Voltage Class | Capacity Class | Typical Application |
|---|---|---|---|---|
| 20G1ALE355AN0NNNNN | PowerFlex 755 | 600 VAC | High Power | Pumps, fans, conveyors |
| 20G1ALE395JN0NNNNN | PowerFlex 755 | 600 VAC | 395 A | Large industrial motors |
| 20G1ALE435JN0NNNNN | PowerFlex 755 | 600 VAC | 435 A | Process machinery |
| 20G1ALE460JN0NNNNN | PowerFlex 755 | 600 VAC | 460 A | Large pumps and compressors |
| 20G1ALE295AN0NNNNN | PowerFlex 755 | 600 VAC | 295 A class | Large industrial motor control |
These models are useful when the project requires different current capacities within the same general PowerFlex platform.
The exact suffix configuration should always be checked before treating one catalog number as a direct substitute for another.
| Application | Suggested PowerFlex 755 Reference | Main Requirement |
|---|---|---|
| Large Pump | 20G1ALE395JN0NNNNN | Variable speed and process control |
| Large Fan | 20G1ALE355AN0NNNNN | Variable airflow |
| Large Conveyor | 20G1ALE395JN0NNNNN | Starting torque and speed control |
| Higher-Power Process Machine | 20G1ALE435JN0NNNNN | Higher current capacity |
| Very Large Pump | 20G1ALE460JN0NNNNN | High motor capacity |
| Large General Industrial Load | 20G1ALE395JN0NNNNN | Balanced high-power capacity |
These are application-oriented reference points rather than automatic replacement recommendations.
Final selection should be based on motor nameplate current and actual load characteristics.
The 600 VAC three-phase configuration is suitable for large industrial motor systems.
Using a higher motor voltage for large power levels can allow the required motor power to be delivered at a lower current than would be required at a substantially lower motor voltage.
This is one reason high-voltage motor systems are common in larger industrial installations.
The 20G1ALE395JN0NNNNN is therefore suited to large electrical systems where substantial motor power is required.
The MCC-style construction makes the drive suitable for centralized electrical installations.
This is useful where several motor drives are installed together in a common electrical room or motor control center.
The 800 mm deep configuration should be taken into account during cabinet layout and electrical-room planning.
For large projects, sufficient space should also be allowed for:
The drive provides more than simple speed adjustment.
It can become part of a complete machine-control system.
The control system can manage:
This allows motor operation to be coordinated with the rest of the production process.
The PowerFlex 755 platform provides a structured approach to drive diagnostics and maintenance.
The drive can provide operating and fault information that can be integrated into a control system.
This can help maintenance personnel determine whether a problem is associated with:
A well-designed networked drive system can therefore provide more information than a conventional standalone motor starter.
When replacing a 20G1ALE395JN0NNNNN, the complete catalog number should be compared.
The following items are particularly important:
| Item | Check |
|---|---|
| Model Number | 20G1ALE395JN0NNNNN |
| Voltage | 600 VAC |
| Phase | 3 Phase |
| Current | 395 A LD |
| Motor Rating | 450 / 400 / 350 HP |
| Frame | 8 |
| Cooling | Forced Air |
| Enclosure | Type 1 / IP20 |
| Cabinet Depth | 800 mm |
| EtherNet/IP | Embedded |
| Dynamic Braking | None |
| Input | AC with Precharge |
| DC Terminals | None |
| Filtering | Filtered |
| CM Jumper | Installed |
| HIM | None |
| Physical Arrangement | Verify before replacement |
| Weight | Verify actual shipping/unit configuration |
The CM jumper configuration is especially important because the J and A catalog configurations differ in this area.
Before connecting a motor, check:
| Motor Parameter | Required Check |
|---|---|
| Motor Voltage | Must match drive application |
| Motor Current | Must be within drive capability |
| Motor HP | Must match selected duty |
| Motor Frequency | Verify |
| Motor Speed | Verify |
| Motor Insulation | Verify for VFD operation |
| Motor Cable | Correct size and type |
| Cable Length | Verify |
| Load Torque | Verify |
| Starting Requirement | Verify |
| Acceleration Time | Verify |
| Deceleration Requirement | Verify |
The motor’s rated current is particularly important.
Two motors with the same horsepower rating can have different current requirements.
| Advantage | Description |
|---|---|
| High Power | Suitable for large industrial motors |
| 600 VAC | Designed for high-voltage industrial motor systems |
| 395 A LD | High continuous current capacity |
| Multi-Duty Rating | Supports LD, ND and HD operating profiles |
| Frame 8 | Large industrial power structure |
| EtherNet/IP | Integrated network communication |
| Forced Air | Suitable for high-power thermal management |
| MCC Style | Fits centralized industrial installations |
| Precharge | Controlled DC bus charging |
| Filtering | Integrated filtered configuration |
| CM Jumper Installed | Specific electrical configuration for this catalog number |
| No HIM | Suitable for networked or remote-control applications |
| Diagnostics | Useful for maintenance and troubleshooting |
| Flexible Applications | Pumps, fans, conveyors, compressors and process equipment |
| Category | Specification |
|---|---|
| Model | 20G1ALE395JN0NNNNN |
| Brand | Allen-Bradley |
| Series | PowerFlex 755 |
| Product | AC Variable Frequency Drive |
| Voltage | 600 VAC |
| Phase | Three Phase |
| Frame | Frame 8 |
| LD Current | 395 A |
| ND Current | 355 A |
| HD Current | 295 A |
| LD Motor Rating | 450 HP |
| ND Motor Rating | 400 HP |
| HD Motor Rating | 350 HP |
| Cooling | Forced Air |
| Enclosure | Type 1 / IP20 |
| Cabinet Depth | 800 mm |
| Cabinet Style | MCC Style |
| Communication | Embedded EtherNet/IP |
| Input | AC Input with Precharge |
| External DC Terminals | None |
| Dynamic Braking | None |
| Filtering | Filtered |
| CM Jumper | Installed |
| HIM | Blank / No HIM |
| Approx. Unit Weight | 84 kg reference |
| Main Application | Large industrial AC motors |
| Typical Loads | Pumps, fans, conveyors, compressors |
| Installation | Industrial MCC / cabinet |
The Allen-Bradley 20G1ALE395JN0NNNNN is a high-power PowerFlex 755 drive intended for industrial motor applications where the motor power level is substantially above the range normally handled by compact general-purpose drives.
Its 600 VAC three-phase input and Frame 8 power structure make it suitable for large industrial electrical systems.
The 395 A Light Duty rating provides a substantial amount of continuous output current, while the 355 A Normal Duty and 295 A Heavy Duty ratings provide different operating options according to the load profile.
The embedded EtherNet/IP interface is another important characteristic.
Rather than operating as a standalone motor controller, the drive can be integrated into an automated control system and exchange operational information with the rest of the machine or plant.
The forced-air cooling system and MCC-style physical arrangement are consistent with the requirements of high-power industrial equipment.
The Allen-Bradley 20G1ALE395JN0NNNNN PowerFlex 755 AC Drive is a high-power three-phase variable frequency drive designed for large industrial motor applications.
The drive is rated for 600 VAC, uses a Frame 8 power structure, and provides a 395 A Light Duty output rating.
Its published motor ratings are approximately 450 HP for Light Duty, 400 HP for Normal Duty, and 350 HP for Heavy Duty.
The drive uses forced-air cooling and a Type 1 / IP20, 800 mm deep MCC-style enclosure.
It includes embedded EtherNet/IP, allowing integration with networked automation systems.
The stated configuration uses AC input with precharge, no external DC terminals, filtered input configuration, no dynamic braking, and no HIM.
One of the defining configuration details of this particular catalog number is the CM jumper installed configuration.
This makes the model distinct from closely related catalog numbers that use a different CM jumper configuration.
The drive is suitable for large pumps, fans, blowers, conveyors, compressors, process machinery, material-handling equipment, water systems, and other large motor-driven industrial equipment.
For physical planning, the unit belongs to the large Frame 8 MCC-style class and uses an approximately 800 mm deep cabinet arrangement.
A listed unit reference gives approximately 84 kg for the unit weight, while the final shipping or installed cabinet weight should be confirmed from the exact mechanical configuration.
The complete catalog number should always be retained when purchasing, replacing, or comparing the drive because configuration characters can change important electrical and mechanical characteristics.
In practical terms, the 20G1ALE395JN0NNNNN is a large-capacity, network-capable industrial drive intended to provide controlled speed, controlled acceleration and deceleration, motor-control functionality, and centralized automation integration for substantial three-phase AC motor loads.