• ABB Bailey NKTT01-3 Infi-Net Termination Cable
  • ABB Bailey NKTT01-3 Infi-Net Termination Cable
  • ABB Bailey NKTT01-3 Infi-Net Termination Cable
  • ABB Bailey NKTT01-3 Infi-Net Termination Cable
Product Overview The ABB Bailey NKTT01-3 Infi-Net Termination Cable is an industrial communication cable used in ABB Bailey INFI 90 / Net 90 Distributed Control Systems (DCS). It is designed to connect ……
ABB Bailey NKTT01-3 Infi-Net Termination Cable
  • ABB Bailey
  • NKTT01-3
  • Infi-Net Termination Cable
  • Sweden (SE)
  • 3 feet
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 25

Our advantage

ABB Bailey NKTT01-3 Infi-Net Termination Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

ABB Bailey NKTT01-3 Infi-Net Termination Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

ABB Bailey NKTT01-3 Infi-Net Termination Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

ABB Bailey NKTT01-3 Infi-Net Termination Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The ABB Bailey NKTT01-3 Infi-Net Termination Cable is an industrial communication cable used in ABB Bailey INFI 90 / Net 90 Distributed Control Systems (DCS). It is designed to connect termination units within the INFI-Net network, ensuring stable and reliable communication between system components.

This 3-foot version is used for short-distance cabinet or rack-level connections, where compact wiring and stable signal integrity are required.

It plays an important role in maintaining proper network termination and supporting uninterrupted data communication across ABB Bailey control systems.


Technical Specifications

Parameter Details
Manufacturer ABB (Bailey)
Model NKTT01-3
Product Type INFI-Net Termination Cable
System Compatibility ABB Bailey INFI 90 / Net 90 DCS
Function Network termination connection
Cable Length 3 feet (0.91 m)
Signal Type INFI-Net communication signals
Shielding Industrial EMI-protected design
Connector Type System-specific termination connectors
Installation Type Pre-terminated industrial cable assembly
Operating Temperature -20°C to +70°C
Storage Temperature -40°C to +85°C
Humidity Range 5%–95% non-condensing
Shipping Weight 3 kg

Function and Working Principle

The NKTT01-3 cable is used to complete and stabilize INFI-Net communication connections within ABB Bailey systems.

It connects termination modules and ensures that the communication path within the network is properly stabilized. This prevents signal disturbance and helps maintain consistent data flow between distributed control units.

By ensuring proper termination, the cable helps the system maintain stable communication performance across industrial environments.


Role in Industrial Control Systems

Within ABB Bailey INFI 90 / Net 90 systems, the NKTT01-3 is used for:

  • Connecting INFI-Net termination modules
  • Supporting network signal stability
  • Completing communication loop structure
  • Reducing signal disturbance in control networks
  • Ensuring reliable system-wide communication

It is an important component in the network communication infrastructure of ABB Bailey DCS systems.


Industrial Applications

The ABB NKTT01-3 is widely used in:

  • Power generation systems
  • Oil and gas facilities
  • Petrochemical plants
  • Water treatment systems
  • Industrial automation systems
  • ABB Bailey legacy DCS installations
  • Distributed control network systems

Installation and System Integration

  • Installed within INFI-Net communication loops
  • Used for termination module connections
  • Requires correct connector alignment and secure locking
  • Shielding must be properly grounded
  • Should be routed away from high-voltage cables
  • Installed by qualified industrial technicians
  • Integrated into ABB Bailey network architecture

Compatible System Components

  • ABB Bailey INFI 90 / Net 90 network interface modules
  • NTCL termination units
  • NICL communication modules
  • Controller systems
  • System backplane communication architecture
  • Industrial network infrastructure components

Recommended Alternative Models

Model Type Key Feature Application
NKTT01-3 Termination cable Short 3 ft connection Cabinet-level termination
NKTT01 Termination cable Standard version General network use
NKTT01-8 Termination cable Longer reach option Larger cabinet layouts
NKTT01-15 Termination cable Extended distance Expanded systems
NKTU series I/O termination cable Field wiring support Input/output systems

Key Advantages

  • Stable INFI-Net communication termination
  • Strong resistance to electrical interference
  • Improves network reliability and stability
  • Supports ABB Bailey distributed control systems
  • Ensures proper signal loop integrity
  • Suitable for continuous industrial operation
  • Reduces communication errors in control systems

Technical FAQs

Q1: What is the main function of NKTT01-3?
It provides termination for INFI-Net communication loops.

Q2: Does it process signals?
No. It only supports network termination and signal stability.

Q3: Where is it used?
It is used in ABB Bailey INFI 90 and Net 90 distributed control systems.

Q4: Why is termination important?
It ensures stable communication and prevents signal reflection or disturbance.


Conclusion

The ABB Bailey NKTT01-3 Infi-Net Termination Cable is an essential component in ABB Bailey distributed control systems. It ensures stable network termination, supports reliable communication integrity, and maintains consistent system performance.

It is widely used in industrial environments such as power plants, petrochemical facilities, and large-scale automation systems where communication stability is critical.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501