• ABB A210-30-11-80 1SFL511001R8011 Contactor
  • ABB A210-30-11-80 1SFL511001R8011 Contactor
  • ABB A210-30-11-80 1SFL511001R8011 Contactor
  • ABB A210-30-11-80 1SFL511001R8011 Contactor
Product Overview The ABB A210-30-11-80 1SFL511001R8011 Contactor is a three-pole electromagnetic contactor designed for switching and controlling electrical power in industrial systems. It belongs to AB……
ABB A210-30-11-80 1SFL511001R8011 Contactor
  • ABB
  • A210-30-11-80 1SFL511001R8011
  • Contactor
  • Sweden (SE)
  • 227 x 140 x 180.5 mm
  • 5.4 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

ABB A210-30-11-80 1SFL511001R8011 Contactor

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

ABB A210-30-11-80 1SFL511001R8011 Contactor

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

ABB A210-30-11-80 1SFL511001R8011 Contactor

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

ABB A210-30-11-80 1SFL511001R8011 Contactor

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The ABB A210-30-11-80 1SFL511001R8011 Contactor is a three-pole electromagnetic contactor designed for switching and controlling electrical power in industrial systems. It belongs to ABB’s A-series contactor range and is suitable for applications such as three-phase motor starting, electrical isolation, bypass switching, and power distribution.

Contactors are essential components in industrial electrical control panels. They allow control circuits to operate high-current power circuits through an electromagnetic switching mechanism. When the contactor coil receives the specified control voltage, the magnetic system operates the contact mechanism, connecting or disconnecting the main power circuit.

The A210-30-11-80 is designed for demanding industrial switching applications. Its main circuit supports an operational voltage of up to 690 V AC, while its AC-3 rated operational current is 210 A at commonly specified 380–415 V operating conditions. The contactor has three normally open main contacts and one normally open plus one normally closed auxiliary contact.

This model uses a 220–230 V AC control coil at 50 Hz or a 230–240 V AC control coil at 60 Hz. Selecting the correct coil supply is important because the control voltage determines whether the electromagnetic mechanism can operate reliably.

The A210-30-11-80 is used in motor control centers, industrial machinery, distribution panels, and other electrical installations where reliable switching of three-phase loads is required.

Technical Specifications

Parameter Specification
Brand ABB
Product Series A Series
Model A210-30-11-80
Product ID 1SFL511001R8011
Product Type Three-Pole AC Contactor
Number of Poles 3P
Main Contacts 3 NO
Auxiliary Contacts 1 NO + 1 NC
Main Circuit Rated Operational Voltage Up to 690 V AC
Rated Control Voltage 220–230 V AC, 50 Hz
Rated Control Voltage 230–240 V AC, 60 Hz
AC-3 Rated Operational Current 210 A at 380–415 V AC, 55°C
AC-1 Rated Operational Current 350 A at 690 V AC, 40°C
Conventional Free-Air Thermal Current 350 A
AC-3 Rated Operational Power 110 kW at 380–415 V AC
Rated Frequency 50/60 Hz
Rated Insulation Voltage 1000 V
Rated Impulse Withstand Voltage 8 kV
Coil Terminal Protection IP20
Main Terminal Protection IP00
Product Width 140 mm
Product Depth 180.5 mm
Product Height 227 mm
Dimensions Provided 227 × 140 × 180.5 mm
Product Net Weight 5.4 kg
Replacement Product ID 1SFL527002R1311

Electrical ratings depend on utilization category, operating voltage, ambient temperature, and installation conditions. Always consult the applicable ABB technical documentation when selecting the contactor for a specific load.

Function and Working Principle

The ABB A210-30-11-80 operates through electromagnetic switching. Its main function is to connect or disconnect an electrical load in response to a control signal.

1. Electromagnetic Coil Operation

The contactor contains an electromagnetic coil and a magnetic operating mechanism. When the specified control voltage is applied, current flows through the coil and creates a magnetic field.

This magnetic field attracts the movable armature, causing the contact mechanism to change position. The main contacts close and establish the electrical connection between the supply and the connected load.

When the coil is de-energized, the magnetic force disappears and the return mechanism moves the contacts back to their normal position.

For this model, the control supply must match the specified coil voltage and frequency. Incorrect coil voltage can result in unreliable operation or damage.

2. Main Power Switching

The A210-30-11-80 has three normally open main contacts. These contacts are used to switch the three phases of a compatible electrical load.

In a motor-control circuit, the contactor connects the motor to the power supply when the control system issues a start command. When the stop command is received, the coil is de-energized and the main contacts open.

The contactor provides switching functionality but does not independently provide all the protection required by a motor circuit. Appropriate short-circuit protection and motor overload protection must be selected separately.

3. Auxiliary Contact Operation

The contactor includes one normally open and one normally closed auxiliary contact.

These contacts are commonly used in control circuits for:

  • Electrical interlocking.
  • Contactor status feedback.
  • PLC input signals.
  • Holding and self-maintaining circuits.
  • Alarm and indication circuits.

Auxiliary contacts allow the contactor’s operating state to be incorporated into a larger control sequence.

4. Motor Starting and Stopping

In an AC-3 application, the contactor is used for starting squirrel-cage motors and switching them off while they are running.

During motor starting, the contactor must withstand the electrical conditions associated with motor inrush current. Its AC-3 rating is therefore more relevant to motor selection than its general thermal current rating.

The A210-30-11-80 has an AC-3 rated operational current of 210 A at 380–415 V AC under the specified temperature conditions. The actual motor selection must also consider starting frequency, load characteristics, and coordination with protective devices.

Role in Industrial Control Systems

The A210-30-11-80 can serve as a main switching component in industrial control panels and motor control centers.

PLC-Based Motor Control

A programmable logic controller can control the contactor through an appropriate relay or output interface. When the PLC receives a start condition and all required interlocks are satisfied, it can energize the contactor coil.

The auxiliary contacts can provide feedback to the control system, helping confirm whether the contactor has changed state.

The PLC should not be treated as a substitute for the electrical protection and safety devices required by the application.

Motor Control Centers

In a motor control center, the contactor forms part of an individual motor feeder or switching assembly. It can be combined with circuit breakers, fuses, overload relays, and control devices to create a complete motor-control circuit.

The contactor’s current and voltage ratings must match the motor and the system’s operating conditions.

Electrical Distribution Panels

The A210-30-11-80 can also be used in distribution and switching arrangements where a remotely controlled three-phase contactor is required.

Its three-pole construction allows the three phases to be switched together through one electromagnetic operating mechanism.

Interlocking and Feedback

The auxiliary contacts can support electrical interlocking between contactors or provide status information to a PLC or control relay.

In applications involving forward/reverse motor control or bypass switching, the control design must prevent incompatible contactors from closing simultaneously.

Industrial Applications

1. Three-Phase Motor Starting

Motor starting is one of the primary applications of the A210-30-11-80. It can switch compatible three-phase motors used in pumps, compressors, conveyors, and industrial machinery.

The contactor must be selected according to the motor’s rated current, operating voltage, starting conditions, and AC-3 requirements.

2. Industrial Pumping Systems

Industrial pumping equipment often requires reliable electrical switching for water circulation, process-fluid transfer, and utility services.

The contactor can connect or disconnect the pump motor according to signals from pressure switches, level sensors, PLCs, or other control devices.

3. Compressor Installations

Large industrial compressor systems use contactors as part of their motor-control arrangements. The A210-30-11-80 can be considered for suitable motor circuits where its electrical ratings meet the compressor’s requirements.

The compressor’s starting method, motor current, and operating cycle should be reviewed before selection.

4. Conveyor and Material-Handling Equipment

Industrial conveyor systems use contactors to control motors responsible for moving materials and products.

The contactor can be integrated with PLC logic, emergency-stop circuits, limit switches, and other control devices to coordinate equipment operation.

5. Bypass Switching

Some industrial installations require a contactor to switch a bypass circuit around another power-control device.

In these applications, the contactor provides the electrical switching function required by the system design. Proper electrical and mechanical interlocking is important to prevent unsafe switching conditions.

6. Industrial Power Distribution

The contactor can be used in electrical distribution assemblies where remote switching of compatible three-phase circuits is required.

The application must remain within the contactor’s applicable utilization-category and short-circuit coordination limits.

Installation and System Integration

Correct installation is essential for reliable contactor operation and electrical safety.

1. Verify the Coil Voltage

Before installation, confirm the control supply voltage and frequency.

The A210-30-11-80 is specified for:

  • 220–230 V AC at 50 Hz.
  • 230–240 V AC at 60 Hz.

Do not assume that contactors with the same frame size have identical coil specifications. Other A210 variants may use different control voltages.

2. Confirm Main Circuit Ratings

Check the system voltage, load current, utilization category, and expected switching frequency.

For motor applications, use the AC-3 rating rather than relying only on the conventional thermal current rating. The contactor’s 210 A AC-3 rating at 380–415 V AC is an important selection reference.

3. Mounting and Panel Layout

The supplied dimensions are 227 × 140 × 180.5 mm, with a product weight of 5.4 kg.

Install the contactor on a suitable mounting surface or panel arrangement. Provide adequate space for cable connections, terminal access, inspection, and maintenance.

The contactor should be installed in an environment that meets its temperature, humidity, contamination, and ventilation requirements.

4. Main Circuit Wiring

The main circuit uses three power poles. Connect the incoming supply and outgoing load conductors according to the terminal markings and ABB wiring instructions.

The main circuit supports busbar connections and appropriately sized copper or aluminum conductors, subject to the manufacturer’s specified connection arrangements.

Ensure that all conductors are correctly sized and securely terminated. Loose connections can cause overheating and damage.

5. Auxiliary Circuit Wiring

The auxiliary contacts can be connected to PLC inputs, relay logic, indication circuits, or interlocking circuits.

Confirm the contact ratings and circuit requirements before connecting electronic control equipment. Auxiliary contacts should not be used beyond their specified electrical limits.

6. Protection and Commissioning

A contactor does not replace a circuit breaker, fuse, or motor overload relay.

A complete motor-control circuit normally requires:

  • Suitable short-circuit protection.
  • Motor overload protection.
  • Correctly rated control wiring.
  • Appropriate grounding.
  • Emergency-stop and interlocking arrangements where required.

After installation, test coil operation, contact switching, auxiliary feedback, and the connected load under controlled conditions.

Compatible System Components

The A210-30-11-80 is generally used with additional electrical and automation components to create a complete switching or motor-control system.

Component Function Integration Considerations
Three-phase AC motor Converts electrical power into mechanical motion Check rated current, voltage, and AC-3 requirements
PLC Controls motor-starting sequences Use an appropriate output interface and control supply
Motor overload relay Protects the motor against overload Select according to motor full-load current
Circuit breaker Provides short-circuit protection and isolation Coordinate with contactor and motor ratings
Fuse assembly Provides circuit protection Select suitable fuse type and rating
Auxiliary relay Extends control and interlocking logic Verify coil and contact ratings
HMI Provides operator commands and status indication Typically communicates through the PLC
Control transformer or power supply Provides the required control voltage Confirm compatibility with the 220–230 V / 230–240 V AC coil
Motor control cabinet Houses switching and protection components Provide suitable space, ventilation, and access

The listed components are examples of equipment used in a complete system. They are not necessarily supplied with the contactor.

Alternative Models and Replacement Considerations

When replacing the A210-30-11-80, the complete product ID and coil specification should be checked.

Alternative Model or Product ID Replacement Considerations
ABB 1SFL527002R1311 Listed replacement product ID; verify technical equivalence and mounting details
ABB A210-30-11 variants Similar contactor family, but coil voltage and suffix configuration may differ
ABB A260 series Higher-rated related contactor family; requires application-specific selection
ABB AF-series contactors Alternative contactor technology; check coil control, terminal layout, and electrical ratings

The replacement product ID is a useful starting point, but it should not be treated as an automatic drop-in replacement.

Before selecting an alternative, compare:

  • Main circuit voltage.
  • AC-3 rated operational current.
  • Motor power rating.
  • Coil voltage and frequency.
  • Main contact configuration.
  • Auxiliary contact configuration.
  • Mounting dimensions.
  • Terminal arrangement.
  • Short-circuit coordination requirements.
  • Control circuit compatibility.

A replacement contactor may require changes to the panel layout, wiring, or control circuit even when its electrical ratings appear similar.

Key Advantages

High-Current Switching Capability

The A210-30-11-80 supports an AC-3 rated operational current of 210 A at 380–415 V AC, making it suitable for appropriately rated industrial motor circuits.

Three-Pole Main Contact Configuration

Its three normally open main contacts allow coordinated switching of three-phase electrical loads.

Integrated Auxiliary Contacts

The 1NO + 1NC auxiliary contact arrangement supports feedback, interlocking, and control-circuit functions without requiring a separate auxiliary contact block for these basic functions.

Defined AC Control Coil

The 220–230 V AC, 50 Hz and 230–240 V AC, 60 Hz coil specification supports integration with compatible industrial control supplies.

Multiple Industrial Applications

The contactor can be used in motor starting, isolation, bypass, and power-distribution applications when correctly selected.

Established ABB A-Series Design

The A210-30-11-80 belongs to ABB’s established A-series contactor range and is relevant to maintenance and replacement projects involving existing installations.

Technical FAQs

1. What is the ABB A210-30-11-80?

It is a three-pole ABB AC contactor with product ID 1SFL511001R8011. It is designed for industrial motor starting, switching, isolation, bypass, and distribution applications.

2. What is the coil voltage of this contactor?

The specified coil voltage is 220–230 V AC at 50 Hz or 230–240 V AC at 60 Hz. Confirm the control supply before installation.

3. How many main contacts does it have?

The contactor has three normally open main contacts, suitable for switching the three phases of a compatible electrical circuit.

4. What auxiliary contacts are included?

It includes one normally open and one normally closed auxiliary contact, commonly used for status feedback and control interlocking.

5. What is its AC-3 rated current?

The A210-30-11-80 has a rated operational current of 210 A at 380–415 V AC under the specified 55°C conditions.

6. What motor power can it handle?

Its documented AC-3 operational power rating is 110 kW at 380–415 V AC. Actual motor selection must also consider current, starting conditions, switching frequency, and protection coordination.

7. Can it be controlled by a PLC?

Yes. A PLC can control the contactor through an appropriate output interface and correctly rated control circuit. Auxiliary contacts can provide status feedback to the PLC.

8. Does this contactor provide motor overload protection?

No. A separate motor overload relay or suitable motor-protection device is required as part of the complete motor-control circuit.

9. What are the dimensions and weight?

The supplied dimensions are 227 × 140 × 180.5 mm, and the product net weight is approximately 5.4 kg.

10. What should be checked before replacing this model?

Verify the product ID, coil voltage, frequency, main contact configuration, auxiliary contacts, AC-3 rating, mounting dimensions, and terminal arrangement. A related model should not be assumed to be directly interchangeable without checking these details.

Procurement and Maintenance Recommendations

When purchasing the ABB A210-30-11-80, verify the complete product ID 1SFL511001R8011 and the coil voltage specification. The suffix is important because ABB contactors within the same product family may use different coil voltages and contact configurations.

For replacement projects, compare the installed contactor’s nameplate with the product documentation. Confirm that the replacement meets the required AC-3 current rating and that the control circuit can supply the correct coil voltage.

For used or surplus units, inspect the main terminals, auxiliary contacts, coil condition, mechanical movement, and visible signs of overheating or contamination. Request clear product photographs and functional test information when the contactor is intended for critical equipment.

During routine maintenance, inspect terminal tightness, contact condition, signs of abnormal heating, and mechanical operation. Any electrical inspection or servicing should be performed by qualified personnel using appropriate isolation and lockout procedures.

Keep the product ID, coil specification, wiring information, and replacement records in the equipment maintenance documentation. This information can reduce identification errors and simplify future procurement.

Conclusion

The ABB A210-30-11-80 1SFL511001R8011 is a three-pole industrial AC contactor designed for motor starting, electrical switching, isolation, bypass, and distribution applications. It features three normally open main contacts, one normally open and one normally closed auxiliary contact, and a control coil rated for 220–230 V AC at 50 Hz or 230–240 V AC at 60 Hz.

With an AC-3 rated operational current of 210 A at 380–415 V AC and a rated motor power of 110 kW under the specified conditions, it is suitable for appropriately engineered industrial switching systems. Correct coil selection, motor protection, and electrical coordination are essential for reliable operation.

For maintenance and replacement applications, verify the full product number and all electrical specifications before installation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501