• Yokogawa F3LE12-1T Ethernet Interface Module
  • Yokogawa F3LE12-1T Ethernet Interface Module
  • Yokogawa F3LE12-1T Ethernet Interface Module
  • Yokogawa F3LE12-1T Ethernet Interface Module
Product Overview The Yokogawa F3LE12-1T is an Ethernet Interface Module designed for the FA-M3 PLC system. It enables fast and reliable communication between PLCs and external systems such as SCADA plat……
Yokogawa F3LE12-1T Ethernet Interface Module
  • Yokogawa
  • F3LE12-1T
  • Ethernet Interface Module
  • Japan
  • 28.98 x 100 x 83.2 mm
  • 0.1 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 49

Our advantage

Yokogawa F3LE12-1T Ethernet Interface Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Yokogawa F3LE12-1T Ethernet Interface Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Yokogawa F3LE12-1T Ethernet Interface Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Yokogawa F3LE12-1T Ethernet Interface Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Yokogawa F3LE12-1T is an Ethernet Interface Module designed for the FA-M3 PLC system. It enables fast and reliable communication between PLCs and external systems such as SCADA platforms, HMI panels, engineering workstations, and industrial controllers via standard Ethernet networks.

This module supports 10/100 Mbps Ethernet communication and is designed for real-time industrial data exchange, remote programming, and system monitoring in distributed automation environments.


Technical Specifications

Parameter Details
Manufacturer Yokogawa
Model F3LE12-1T
Product Type Ethernet Interface Module
System Compatibility FA-M3 PLC system
Ethernet Standard IEEE 802.3
Communication Speed 10/100 Mbps (auto-negotiation)
Interface Type 10BASE-T / 100BASE-TX
Connector RJ-45
Protocols TCP/IP, UDP/IP, ICMP, ARP
Network Functions Remote programming, monitoring, data exchange
Additional Functions Event communication, system diagnostics
Max Cable Length 100 m per segment
Port Count 1 Ethernet port
Power Consumption ~330 mA
Dimensions 28.98 × 100 × 83.2 mm
Weight 0.1 kg

Function and Working Principle

The F3LE12-1T functions as a communication gateway module that connects FA-M3 PLC systems to Ethernet-based networks.

Working Principle

  1. PLC CPU exchanges data with the module via internal system bus
  2. The module converts PLC data into Ethernet frames
  3. Data is transmitted using TCP/IP or UDP/IP protocols
  4. External systems access or update PLC memory in real time
  5. Feedback and control signals are returned to the PLC

PLCFA−M3↔Ethernet (10\/100 Mbps, TCP\/IP)PLC_{FA-M3} \leftrightarrow Ethernet\,(10\/100\,Mbps,\ TCP\/IP)


Key Functions

  • Enables Ethernet connectivity for FA-M3 PLC systems
  • Supports 10/100 Mbps auto-negotiation
  • Provides real-time PLC data communication
  • Allows remote programming and maintenance
  • Integrates with SCADA and HMI systems
  • Supports event-based data exchange
  • Enables network-based PLC memory access

System Role

The module serves as a core Ethernet communication interface:

FA-M3 PLC → F3LE12-1T → Ethernet Network → SCADA / Engineering PC / Industrial Systems

It is commonly used in:

  • Factory automation systems
  • Remote monitoring and diagnostics
  • Distributed control systems
  • PLC programming and maintenance
  • Data acquisition and logging systems
  • Industrial network integration

Industrial Applications

  • Manufacturing automation
  • Oil & gas facilities
  • Petrochemical plants
  • Power generation systems
  • Water treatment systems
  • Building automation
  • Process control industries
  • Industrial monitoring networks

Installation Guidelines

  • Install in FA-M3 rack system only
  • Use Cat5e or higher Ethernet cables
  • Maintain maximum cable length of 100 meters per segment
  • Configure IP settings correctly before operation
  • Avoid high electromagnetic interference areas
  • Use industrial-grade network switches for reliability

Compatible Systems

  • Yokogawa FA-M3 PLC CPUs
  • SCADA systems
  • HMI panels and industrial PCs
  • Engineering software (e.g., WideField3)
  • Ethernet-based industrial networks

Key Advantages

  • High-speed 10/100 Mbps Ethernet communication
  • Stable and reliable industrial-grade performance
  • Supports real-time monitoring and control
  • Enables remote PLC programming
  • Compact and lightweight design (0.1 kg)
  • Easy integration into modern automation systems
  • Suitable for distributed industrial networks

Technical FAQs

Q1: What is the main function of the F3LE12-1T?
It enables Ethernet communication between FA-M3 PLCs and external systems.

Q2: What is its communication speed?
It supports 10 Mbps and 100 Mbps (auto-negotiation).

Q3: Can it be used for remote programming?
Yes, it supports remote PLC programming and diagnostics.

Q4: What is the maximum cable distance?
Up to 100 meters per Ethernet segment.


Conclusion

The Yokogawa F3LE12-1T Ethernet Interface Module is a compact and high-performance networking solution for FA-M3 PLC systems. With support for 10/100 Mbps communication, remote programming, and real-time data exchange, it is ideal for modern industrial automation and distributed control applications.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501