The 330851-02-000-040-10-00-CN is a compact eddy current proximity probe designed for precise, non-contact measurement of shaft vibration, axial displacement, and rotor movement in rotating machinery.
This model belongs to the NSv short-range configuration within the 3300 XL proximity transducer family. The “CN” suffix typically indicates a regional configuration or compliance variation used for specific installation or supply-chain requirements.
The probe is designed for applications where installation space is limited but measurement stability, accuracy, and long-term reliability are essential.
It operates using the eddy current principle, where changes in distance between the probe tip and a conductive target are converted into proportional electrical signals.
This series is designed for compact machinery environments requiring high precision, stable signal output, and resistance to harsh industrial conditions.
The 330851-02-000-040-10-00-CN is widely used in:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog voltage signal |
| Measurement principle | Eddy current induction |
| Output impedance | Low impedance industrial design |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 2 mm (NSv extended calibration variant) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response |
| Repeatability | Excellent consistency |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +120°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | Industrial-grade durability |
| EMI protection | Strong electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Probe design | Compact NSv miniature type |
| Cable type | Shielded coaxial cable |
| Cable length options | 2 m / 5 m / 10 m |
| Total system weight | ~0.25 kg |
| Probe weight | ~0.06 kg |
| Installation type | Threaded mounting structure |
The system operates based on eddy current induction:
This enables precise non-contact measurement of micro-level shaft motion in rotating machinery systems.
| Parameter | 330851-02-000-040-10-00-CN | 330850-90-000-040-10-00-CN | 330852-02-000-040-10-00-CN | 330853-02-000-040-10-00-CN | 330854-02-000-040-10-00-CN |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | Compact probe | Compact probe | Compact probe | Compact probe | Compact probe |
| Weight (kg) | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg |
| Parameter | 330780-NS-40-10-CN | 330881-28-NS-40-10-CN | 330103-00-NS-40-10-00-CN | 330106-05-NS-40-10-00-CN | 330104-00-NS-40-10-00-CN |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 80×120×35 mm | 110×160×50 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 0.18 kg | 1.9 kg | 0.95 kg | 0.95 kg | 0.95 kg |
| Parameter | 330901-02-40-10-CN | 330905-02-40-10-CN | 330909-02-40-10-CN | 330910-02-40-10-CN | 330930-02-40-10-CN |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 120×180×60 mm | 100×160×50 mm | 90×140×40 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330851-02-000-040-10-00-CN is a compact NSv eddy current proximity probe designed for stable and accurate displacement measurement in rotating machinery systems. It provides reliable performance, high sensitivity, and strong environmental resistance, making it suitable for continuous industrial monitoring and predictive maintenance applications.