The 330851-02-000-026-10-00-00 is a compact eddy current proximity probe designed for precise, non-contact measurement of shaft vibration, axial displacement, and rotor dynamics in rotating machinery.
This configuration belongs to a short-range NSv probe variant, optimized for compact mechanical installations where high measurement sensitivity and stable signal output are required. It is commonly used in machinery protection and condition monitoring systems operating in continuous industrial environments.
The system operates by generating a high-frequency electromagnetic field at the probe tip. Changes in the gap between the probe and a conductive target surface are converted into proportional voltage signals, enabling accurate displacement and vibration measurement.
This series is designed for compact machinery applications requiring high sensitivity, stability, and reliable long-term performance in constrained installation spaces.
The 330851-02-000-026-10-00-00 is widely used in industrial systems such as:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog voltage signal |
| Measurement principle | Eddy current induction |
| Output impedance | Low impedance industrial design |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 2 mm (NSv short-range configuration) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response |
| Repeatability | Excellent consistency |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +120°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | Industrial-grade robustness |
| EMI protection | Strong electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Probe design | Compact NSv miniature type |
| Cable type | Shielded coaxial cable |
| Cable length options | 2 m / 5 m / 10 m |
| Total system weight | ~0.25 kg |
| Probe weight | ~0.06 kg |
| Installation type | Threaded mounting structure |
The system operates based on eddy current induction:
This enables precise non-contact measurement of micro-level shaft motion in rotating machinery.
| Parameter | 330851-02-000-026-10-00-00 | 330850-90-000-026-10-00-00 | 330852-02-000-026-10-00-00 | 330853-02-000-026-10-00-00 | 330854-02-000-026-10-00-00 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe |
| Weight (kg) | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg |
| Parameter | 330780-NS-26-10-00 | 330881-28-NS-26-10-02 | 330103-00-NS-26-10-02-00 | 330106-05-NS-26-10-02-00 | 330104-00-NS-26-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 80×120×35 mm | 110×160×50 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 0.18 kg | 1.9 kg | 0.95 kg | 0.95 kg | 0.95 kg |
| Parameter | 330901-02-26-10-02-05 | 330905-02-26-10-02-00 | 330909-02-26-10-02-05 | 330910-02-26-10-02-00 | 330930-02-26-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 120×180×60 mm | 100×160×50 mm | 90×140×40 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330851-02-000-026-10-00-00 is a short-range NSv eddy current proximity probe designed for high-precision displacement and vibration monitoring in compact rotating machinery systems. It delivers stable performance, high sensitivity, and strong environmental resistance, making it suitable for continuous industrial condition monitoring and predictive maintenance applications.