The 330851-01-000-020-90-01-05 is a compact eddy current proximity probe assembly designed for high-precision, non-contact measurement of shaft vibration and displacement in rotating machinery systems.
It is typically used in machinery protection and condition monitoring applications where space is limited and measurement accuracy must remain stable under continuous industrial operation.
The system detects changes in the electromagnetic field between the probe tip and a conductive target surface, converting these variations into a proportional analog voltage signal for displacement tracking.
This series is optimized for small shaft diameter applications requiring compact installation and high measurement sensitivity.
The 330851-01-000-020-90-01-05 is widely used in industrial monitoring environments such as:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog voltage signal |
| Measurement principle | Eddy current induction |
| Output impedance | Industrial standard low impedance |
| Frequency response | Up to 10 kHz |
| Signal stability | High long-term stability |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 2 mm (NSv short-range design) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response |
| Repeatability | Excellent stability |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +120°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | Industrial-grade robustness |
| EMI protection | High electromagnetic shielding |
| Parameter | Specification |
|---|---|
| Probe tip diameter | Compact NSv miniature design |
| Cable type | Shielded coaxial cable |
| Cable length | 2 m / 5 m / 10 m options |
| Total system weight | ~0.25 kg |
| Probe weight | ~0.06 kg |
| Installation type | Threaded mounting structure |
The system operates based on eddy current induction:
This enables precise non-contact measurement of micro-level shaft motion.
| Parameter | 330851-01-000-020-90-01-05 | 330850-90-000-020-90-01-05 | 330852-01-000-020-90-01-05 | 330853-01-000-020-90-01-05 | 330854-01-000-020-90-01-05 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe |
| Weight (kg) | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg |
| Parameter | 330780-NS-90-01-00 | 330881-28-NS-90-02-02 | 330103-00-NS-90-10-02-00 | 330106-05-NS-90-10-02-00 | 330104-00-NS-90-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 80×120×35 mm | 110×160×50 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 0.18 kg | 1.9 kg | 0.95 kg | 0.95 kg | 0.95 kg |
| Parameter | 330901-01-90-10-02-05 | 330905-01-90-10-02-00 | 330909-01-90-10-02-05 | 330910-01-90-10-02-00 | 330930-01-90-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 120×180×60 mm | 100×160×50 mm | 90×140×40 mm | 90×140×40 mm |
| Weight (kg) | 1.8 kg | 2.5 kg | 2.1 kg | 1.7 kg | 1.5 kg |
The 330851-01-000-020-90-01-05 is a compact NSv eddy current proximity probe designed for small shaft vibration and displacement monitoring. It offers high precision, stable long-term performance, and strong environmental resistance, making it suitable for modern industrial machinery protection systems.