The 330851-01-000-020-10-00-05 is a high-performance eddy current proximity probe assembly designed for precise, non-contact measurement of shaft vibration, axial position, and rotor displacement in rotating machinery.
It is typically used in industrial machinery protection systems where continuous monitoring of shaft movement is required to ensure stable operation and early fault detection.
The system operates by generating an electromagnetic field between the probe tip and a conductive metal target surface, converting distance variation into a proportional electrical signal for downstream monitoring and analysis.
This series is designed for smaller shaft applications where compact installation, high sensitivity, and stable long-term performance are required.
The 330851-01-000-020-10-00-05 is widely applied in industrial monitoring systems such as:
| Parameter | Specification |
|---|---|
| Operating voltage | 24 V DC |
| Output signal | Analog voltage signal |
| Measurement principle | Eddy current induction |
| Output impedance | Standard industrial low impedance |
| Frequency response | Up to 10 kHz |
| Signal stability | High stability under long-term operation |
| Parameter | Specification |
|---|---|
| Measurement range | 0 – 2 mm (NSv optimized range) |
| Resolution | ≤ 1 μm |
| Accuracy | ±0.25% – ±0.5% FS |
| Linearity | High linear response |
| Repeatability | Excellent consistency |
| Parameter | Specification |
|---|---|
| Operating temperature | -40°C to +120°C |
| Storage temperature | -55°C to +125°C |
| Humidity | 5% – 95% non-condensing |
| Vibration resistance | High industrial-grade tolerance |
| EMI protection | Strong shielding against interference |
| Parameter | Specification |
|---|---|
| Probe body dimensions | Approx. 8 mm–11 mm tip diameter (NSv compact design) |
| Cable type | Coaxial shielded cable |
| Cable length | 2 m / 5 m / 10 m options |
| Total system weight | ~0.25 kg |
| Probe weight | ~0.06 kg |
| Mounting type | Threaded industrial installation |
The system operates based on eddy current induction:
This allows highly precise non-contact measurement of micro-level shaft movement.
| Parameter | 330851-01-000-020-10-00-05 | 330850-90-00-020-10-00-05 | 330852-01-000-020-10-00-05 | 330853-01-000-020-10-00-05 | 330854-01-000-020-10-00-05 |
|---|---|---|---|---|---|
| Measurement type | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement | Eddy current displacement |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm | 0–2 mm |
| Accuracy | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS | ±0.25–0.5% FS |
| Dimensions | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe | Compact NSv probe |
| Weight (kg) | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg | 0.25 kg |
| Parameter | 330780-NS-01-00 | 330881-NS-28-10-02-02 | 330103-NS-00-12-10-02-00 | 330106-NS-05-60-10-02-00 | 330104-NS-00-12-10-02-00 |
|---|---|---|---|---|---|
| System type | Proximity probe | Signal module | Proximity probe | Proximity probe | Proximity probe |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency range | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm | 2–5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 80×120×35 mm | 110×160×50 mm | 85×130×35 mm | 85×130×35 mm | 85×130×35 mm |
| Weight (kg) | 0.18 kg | 1.9 kg | 0.95 kg | 0.95 kg | 0.95 kg |
| Parameter | 330901-01-NS-10-02-05 | 330905-01-NS-10-02-00 | 330909-01-NS-10-02-05 | 330910-01-NS-10-02-00 | 330930-01-NS-10-02-00 |
|---|---|---|---|---|---|
| Product type | Proximity probe | Signal conditioner | High sensitivity probe | Vibration probe | Industrial probe unit |
| Technology | Eddy current | Eddy current | Eddy current | Eddy current | Eddy current |
| Voltage | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
| Frequency response | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz | Up to 10 kHz |
| Measurement range | 5 mm | 5 mm | 7 mm | 5 mm | 5 mm |
| Accuracy | ±0.5% FS | ±0.5% FS | ±0.25% FS | ±0.5% FS | ±0.5% FS |
| Dimensions | 90×140×40 mm | 120×180×60 mm | 100×160×50 mm | 90×140×40 mm | 90×140×40 mm |
| Weight (kg) | 0.22 kg | 2.1 kg | 0.28 kg | 0.20 kg | 0.18 kg |
The 330851-01-000-020-10-00-05 is a compact NSv eddy current proximity probe designed for small shaft applications requiring high-precision displacement monitoring. It provides strong stability, high sensitivity, and excellent environmental resistance, making it suitable for continuous industrial machinery protection systems.