Model: Bently Nevada 3500/04 176449‑01+125680‑01
Brand: [Brand Name Hidden]
Series: [Series Name Hidden]
| Parameter | Specification |
|---|---|
| Model Number | 3500/04 176449‑01 + 125680‑01 |
| Dimensions | 300 mm × 150 mm × 200 mm |
| Weight (kg) | 4.2 kg |
| Power Supply | 24 V DC (nominal) |
| Input Channels | 4× BNC (configurable) |
| Output Channels | 2× relay outputs + 2× 4–20 mA analog outputs |
| Diagnostics | Built‑in self‑test, fault LEDs, communication port |
| Operating Temp | –20 °C to +60 °C |
| Storage Temp | –40 °C to +85 °C |
| Shock/Vibration | 30 g shock; 5–500 Hz vibration per industrial spec |
| Mounting | DIN‑rail or panel mount |
| Communication | RS‑485 (Modbus compatible) |
The Bently Nevada 3500/04 176449‑01+125680‑01 is a precision monitoring device designed for reliable real‑time analysis of rotating machinery. Compact yet robust, it integrates multiple I/O channels to interface with sensors, control systems, and diagnostic tools. Its rugged construction suits demanding industrial environments. With built‑in self‑test and diagnostic LEDs, it enables fast fault detection and troubleshooting. The device supports modular mounting, offers flexible communication options, and is engineered to integrate seamlessly into advanced condition‑monitoring architectures.
It is ideally placed where early detection of vibration, temperature anomalies, or bearing issues in motors, turbines, compressors, or generators is critical. The dual relay and analog outputs allow for both discrete alarm actions and analog trend logging, enhancing plant safety and predictive maintenance workflows.
Rotating Machine Monitoring: Turbines, compressors, pumps, generators
Predictive Maintenance Systems: Continuous trend‑based alerts
Process Safety Integration: Triggering alarms and shutdowns upon anomalies
Industrial Automation: Remote diagnostics via Modbus
Critical Asset Protection: In power plants, refineries, and heavy industries
High Reliability: Rugged design withstands shock, vibration, and temperature extremes
Versatile Connectivity: Combines analog, relay, and serial options for flexible integration
Self‑Diagnostics: On‑board testing enhances uptime and simplifies maintenance
Compact & Modular: Space‑efficient for rack or panel use; easy to swap or expand
Precise Measurement: High‑resolution analog outputs support early detection of subtle defects
Interoperability: Compatible with common industrial networks and condition monitoring suites
The brand (name hidden) is known for its rigorous industrial instrumentation heritage and expert engineering in machinery protection. The series (name hidden) emphasizes modular, field‑ready devices optimized for long‑term stability and precision in vibration and condition monitoring scenarios.
| Model | Dimensions | Weight (kg) | Channels / Features |
|---|---|---|---|
| 3500/01 176440‑02 | 250 × 130 × 180 mm | 3.8 kg | 2× analog inputs, 1× relay output, RS‑232 interface |
| 3500/02 176441‑03 | 270 × 140 × 190 mm | 4.0 kg | 4× analog inputs, 2× relay outputs, Ethernet port |
| 3500/03 176442‑04 | 300 × 150 × 200 mm | 4.1 kg | 4× analog inputs, 4× relay outputs, built‑in display |
| 3500/05 176450‑05 | 320 × 160 × 210 mm | 4.5 kg | 6× analog inputs, 2× relay, dual‑redundant power supplies |
| 3500/06 176460‑06 | 350 × 170 × 220 mm | 5.0 kg | 8× analog inputs, 4× relay, dual serial / Ethernet comms |
| Model | Dimensions | Weight (kg) | Key Features |
|---|---|---|---|
| 3200/10 165321‑01 | 200 × 120 × 150 mm | 2.5 kg | Simple 2‑channel analog monitor, low‑cost, basic alarm outputs |
| 3300/20 168220‑02 | 220 × 130 × 170 mm | 2.8 kg | 4× analog, single relay, digital display |
| 3400/30 170330‑03 | 250 × 140 × 180 mm | 3.2 kg | 4× analog, dual‑relay, Modbus‑RTU |
| 3600/40 180440‑04 | 280 × 145 × 190 mm | 3.9 kg | 6× analog, programmable thresholds, Ethernet comms |
| 3700/50 190550‑05 | 300 × 150 × 200 mm | 4.3 kg | 8× analog, 4× relay, redundancy, SNMP support |
Q1: What is the purpose of combining two model numbers (176449‑01 + 125680‑01)?
A1: It denotes the base module (176449‑01) plus an extension or option board (125680‑01) that adds enhanced I/O or communications capabilities.
Q2: Can this unit operate on 24 V DC only, or is 48 V supported?
A2: It is rated for 24 V DC nominal; 48 V is not supported and may damage internal circuitry unless explicitly ordered with a converter module.
Q3: How are firmware updates handled?
A3: Updates are applied via the RS‑485 port using a manufacturer‑provided firmware utility. The device must be taken offline and rebooted to complete the operation.
Q4: What self‑tests are included?
A4: The unit tests analog input ranges, relay activation logic, internal power health, memory integrity, and communication port function on every startup and periodically in‑service.
Q5: Is there a backup power or battery?
A5: No internal battery backup is included. If external power is lost, the device resets; for critical systems, external UPS or dual supply options are advised.
Q6: Can it log data onboard?
A6: It does not include onboard logging. Real‑time data must be captured by a connected PCM/SCADA or condition monitoring system.
Q7: How do I configure the analog output scaling?
A7: Scaling (e.g. 4–20 mA calibration) is set via a configuration tool over RS‑485; ranges and zero/span values can be tailored to sensor outputs.
Q8: What maintenance is recommended?
A8: Regular visual inspection of connectors, firmware updates, annual calibration of analog output, and functional test of relay contacts are recommended.
Q9: Is diagnostic firmware proprietary? Can I write my own?
A9: Diagnostic firmware is proprietary to the brand. Custom firmware is not supported and may void warranty or impair safety.
Q10: What happens when a critical fault occurs?
A10: The device opens relay circuits, drives fault LEDs, and reports the fault code via RS‑485. Analog outputs default to a safe output (e.g. 20 mA) or zero, depending on configuration.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.