Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Siemens 6AG4012-2CB40-0XX0 is a SIMATIC IPC347G industrial rack-mounted computer designed for industrial computing, automation-related applications, and equipment-level data processing. Its 19-inch, 4U chassis allows installation in standard industrial cabinets and equipment racks, making it suitable for centralized computing environments in manufacturing facilities.
Industrial computers play an important role in modern automation systems. They provide the computing resources required for visualization, data collection, process monitoring, engineering applications, and communication between industrial equipment and higher-level information systems.
The IPC347G platform combines a rack-oriented mechanical design with industrial communication interfaces and conventional PC connectivity. Its 430 mm width and 176 mm height are suitable for standard rack installations, while the 465.8 mm depth should be considered when planning cabinet space, cable routing, and ventilation.
The 6AG4012-2CB40-0XX0 ordering code should be distinguished from related configurations ending in 0BX0. Operating system, memory, and storage details should be checked against the exact product configuration before deployment.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Product Family | SIMATIC IPC |
| Model | 6AG4012-2CB40-0XX0 |
| Product Type | Rack-Mounted Industrial Computer |
| Platform | SIMATIC IPC347G |
| Chassis Format | 19-inch rack |
| Rack Height | 4U |
| Dimensions (W × H × D) | 430 × 176 × 465.8 mm |
| Weight | 17 kg |
| Power Supply Input | 100–240 V AC |
| Industrial Ethernet | 2 × Gigabit Ethernet |
| Serial Communication | 2 × COM, supporting RS232/RS422/RS485 |
| Display Interfaces | 1 × DisplayPort, 1 × VGA |
| USB Connectivity | Available; exact port configuration should be checked against the product documentation |
| Maximum Main Memory | Up to 32 GB for the IPC347G platform |
| Front Protection Rating | IP20 |
| Rear Protection Rating | IP20 |
| Mounting Orientation | Horizontal or vertical, subject to installation instructions |
Configuration note: The exact processor, installed RAM, storage capacity, and operating system should be verified from the product’s original ordering record or nameplate. Specifications from the related 0BX0 version should not automatically be applied to the 0XX0 model.
The IPC347G uses a 19-inch, 4U rack format. This design makes it suitable for industrial control cabinets, server-style equipment racks, and centralized automation installations.
Its mechanical structure allows the computer to be installed alongside industrial network equipment, communication devices, and other control-system components. Proper rack support is important because the unit weighs approximately 17 kg.
The installation space should also account for the computer’s full depth, rear cable connections, airflow requirements, and access for maintenance.
As an industrial PC, the 6AG4012-2CB40-0XX0 provides a platform for running compatible industrial software and general-purpose computing applications.
Depending on the installed hardware and software configuration, typical tasks may include:
The available processing capacity depends on the exact CPU and memory configuration supplied with the individual unit.
The IPC347G platform provides two Gigabit Ethernet interfaces. These connections support communication with compatible industrial networks, engineering workstations, servers, and other Ethernet-enabled equipment.
Separate network interfaces can be useful when an installation requires different network connections for machine communication and higher-level data exchange.
Network segmentation, addressing, and access permissions should be configured according to the plant’s network architecture and cybersecurity requirements.
The computer supports two COM interfaces with RS232, RS422, and RS485 communication capabilities.
Serial connectivity remains important in many industrial installations because existing equipment may use established serial communication standards. These interfaces can support communication with compatible instruments, controllers, drives, and other industrial devices.
The actual communication standard and wiring arrangement must be selected according to the connected equipment. RS232, RS422, and RS485 are electrically different interfaces and should not be treated as interchangeable.
The IPC347G platform provides DisplayPort and VGA display interfaces.
These connections allow the computer to be integrated with compatible industrial monitors and operator workstations. DisplayPort supports digital video transmission, while VGA is useful when maintaining compatibility with older display equipment.
The selected monitor, resolution, and cable arrangement should be checked against the computer’s graphics specifications.
Industrial PCs are commonly used as computing platforms for production monitoring systems. The 6AG4012-2CB40-0XX0 can support compatible applications that collect machine information, display operating conditions, and provide operators with access to production data.
In a factory environment, it may communicate with PLCs and other automation devices through Ethernet or serial connections.
Supervisory Control and Data Acquisition systems require computing resources for process visualization, data handling, alarm presentation, and operator interaction.
When the installed hardware and operating system meet the software requirements, the IPC347G platform can serve as a computer for compatible SCADA or HMI applications.
Before deployment, confirm the software version, operating system support, available memory, storage capacity, and required communication drivers.
Manufacturing facilities often collect information from multiple machines and production stations. An industrial rack PC can provide a local platform for receiving, processing, and storing operational data.
The two Ethernet interfaces and serial communication capabilities provide options for connecting compatible industrial equipment.
Certain production machines require a dedicated computer for equipment management, local visualization, engineering tools, or communication with peripheral devices.
The rack-mounted format makes the IPC347G suitable for machine control cabinets where sufficient space and ventilation are available.
The computer can be incorporated into an industrial network as a workstation or application host. Its Ethernet interfaces support connections to compatible network infrastructure, while serial ports provide connectivity for equipment using traditional communication standards.
Network configuration should follow the plant’s security policies and avoid unnecessary connections between operational technology and external networks.
Correct installation helps maintain stable operation and reduces the risk of hardware faults.
Check the product nameplate and confirm the complete ordering number: 6AG4012-2CB40-0XX0.
Inspect the chassis, mounting points, power connector, ventilation openings, and external interfaces. If the computer has been transported or stored for an extended period, allow it to reach the installation environment before powering it on.
Confirm that the cabinet supports a 19-inch, 4U installation and can accommodate the computer’s 465.8 mm depth.
Because the unit weighs approximately 17 kg, use suitable rack supports and mounting hardware. Do not rely on front mounting points alone if the installation arrangement requires additional mechanical support.
The IPC347G platform uses a 100–240 V AC power supply.
Before connecting the computer, verify that the available supply voltage is within the specified range and that protective earthing is correctly implemented. Inspect the power cable and connector for damage.
Power should be disconnected before carrying out internal hardware work or changing electrical connections.
Connect Ethernet cables to the appropriate network interfaces. Where serial equipment is used, verify the communication standard, pin assignment, cable type, and signal reference before connecting the device.
Connect the display through a compatible DisplayPort or VGA cable. Keyboard, mouse, and other peripherals should be selected according to the available interfaces.
After powering on the computer, check the startup process and confirm that the installed processor, memory, and storage devices are recognized correctly.
For the 0XX0 ordering variant, verify the supplied operating system status. Do not assume that a Windows installation is included simply because a related 0BX0 configuration is available.
Install only operating systems and industrial applications supported by the actual hardware configuration.
Test Ethernet connectivity with the intended network devices. For serial communication, verify the selected COM port and communication parameters, including baud rate, parity, data bits, and stop bits.
Complete application-level tests before connecting the computer to production equipment.
Regular maintenance helps improve equipment availability and reduce unexpected downtime.
| Problem | Possible Cause | Recommended Inspection |
|---|---|---|
| Computer does not start | Power supply problem or loose connection | Check AC input, power cable, and power indication |
| No display output | Monitor or cable issue | Check DisplayPort/VGA connection and monitor input |
| Ethernet communication failure | Incorrect network settings or cable fault | Inspect network cable, IP configuration, and interface status |
| Serial communication failure | Incorrect COM settings or wiring | Verify RS232/RS422/RS485 selection and communication parameters |
| System runs slowly | High CPU or memory utilization | Review running applications and system resource usage |
| Unexpected shutdown | Power instability or thermal problem | Check supply quality, cooling, and system event records |
| Storage device not detected | Drive connection or storage failure | Inspect drive recognition and storage health |
| Operating system fails to start | Boot configuration or software corruption | Check boot settings and system recovery options |
| Intermittent network connection | Cable, switch, or network configuration issue | Test the cable and inspect network equipment |
| Excessive internal temperature | Restricted airflow or dust accumulation | Inspect ventilation openings and cabinet cooling |
A practical maintenance routine should include:
Internal cleaning and component replacement should be performed by qualified personnel using appropriate electrostatic discharge protection.
The 6AG4012-2CB40-0XX0 belongs to the SIMATIC IPC347G family, but different ordering suffixes can represent different delivery configurations.
The distinction between 0XX0 and 0BX0 is particularly important when purchasing replacement equipment or preparing an operating-system installation.
Before ordering or installing the computer, confirm the following:
A computer with similar dimensions and interface options may still have a different hardware or software configuration. Exact catalog-number verification is therefore essential for replacement planning.
1. What is the Siemens 6AG4012-2CB40-0XX0?
It is a Siemens SIMATIC IPC347G industrial rack-mounted computer designed for industrial computing, automation applications, and equipment-level data processing.
2. What rack format does this computer use?
It uses a 19-inch, 4U rack format, allowing installation in compatible industrial equipment cabinets.
3. What are its dimensions and weight?
The supplied dimensions are 430 × 176 × 465.8 mm, and the supplied weight is 17 kg.
4. What input voltage does the IPC347G platform support?
The platform supports a 100–240 V AC power input. The electrical supply and protective earthing should be checked before installation.
5. Which Ethernet interfaces are available?
The IPC347G platform provides two Gigabit Ethernet interfaces for communication with compatible industrial and standard network equipment.
6. Does the computer support serial communication?
Yes. The platform provides two COM interfaces supporting RS232, RS422, and RS485 communication standards.
7. Which display connections are available?
The platform provides one DisplayPort and one VGA interface for compatible monitors.
8. Does the 6AG4012-2CB40-0XX0 include a preinstalled operating system?
The 0XX0 suffix must be checked against the exact ordering documentation. Do not assume it has the same operating system delivery configuration as a related 0BX0 model.
9. Can this computer be used for SCADA or HMI applications?
It can serve as a computing platform for compatible SCADA and HMI software, provided the processor, memory, storage, operating system, and application requirements are satisfied.
10. What should be checked before replacing an existing IPC347G?
Confirm the full catalog number, processor, RAM, storage, operating system, interfaces, mechanical dimensions, and software compatibility. Similar-looking models may have different delivery configurations.
The Siemens 6AG4012-2CB40-0XX0 SIMATIC IPC347G is a 19-inch, 4U industrial rack-mounted computer designed for industrial computing and automation-related applications. Its rack-compatible enclosure, Gigabit Ethernet interfaces, serial communication ports, and display connections make it suitable for a range of factory computing and monitoring environments.
For maintenance teams and industrial system integrators, the exact ordering configuration is an important consideration. Confirming the processor, memory, storage, and operating system before installation or replacement helps avoid compatibility problems and supports reliable long-term operation.