Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen Bradley 440R-W23222 is a Guardmaster MSR330P Group 2 safety relay output module developed for modular industrial safety control systems. It belongs to Rockwell Automation’s MSR300 safety relay family and provides three normally open safety outputs and one normally closed auxiliary output.
This module is designed for applications where different machine areas require independently controlled safety output groups. Rather than operating as a standalone safety controller, the 440R-W23222 works as part of a compatible MSR300 configuration. Its power and system connection are provided through the modular base arrangement.
The Group 2 designation distinguishes this module’s intended output group within a multi-zone safety system. It can be used in automated production lines, robotic work cells, conveyor installations, and other machinery requiring coordinated safety functions.
| Parameter | Description |
|---|---|
| Brand | Allen Bradley |
| Manufacturer | Rockwell Automation |
| Model | 440R-W23222 |
| Product Family | Guardmaster MSR300 |
| Module | MSR330P Group 2 |
| Product Type | Safety Relay Output Module |
| Safety Inputs | None |
| Safety Outputs | 3 Normally Open (NO) |
| Auxiliary Outputs | 1 Normally Closed (NC) |
| Operating Power | 24V DC from compatible base unit |
| Terminals | Removable |
| Reset Configuration | Selected on base module |
| Mounting | DIN rail |
| Dimensions | 114.5 × 22.5 × 99 mm |
| Weight | 0.2 kg |
| Lifecycle Status | Discontinued |
The dimensions and weight are based on the supplied product information. Confirm the mechanical drawing before using these values for cabinet layout or replacement planning.
The MSR330P Group 2 module provides output switching for a designated safety zone within an MSR300 system. Its function is to extend the safety output capacity of the modular arrangement.
The 440R-W23222 provides three normally open safety outputs. These contacts can be integrated into suitable safety-related control circuits, depending on the machine’s electrical design.
In a multi-zone production system, Group 2 may be assigned to a particular machine section or hazard area. For example, one group could control the stopping arrangement for a conveyor section, while other output modules serve different machine zones.
The module’s output contacts must be used in accordance with the manufacturer’s electrical ratings and the validated safety architecture.
A separate normally closed auxiliary output is provided for monitoring or signaling purposes. It can be incorporated into a suitable control or diagnostic circuit.
The auxiliary contact should not be treated as an additional safety output unless the applicable product documentation explicitly supports that use.
The module receives its operating power through the compatible MSR300 base-unit arrangement. It is not intended to function as an independently powered safety relay.
This modular design reduces the need for a separate standalone controller for every output group and allows safety functions to be organized across a larger machine installation.
The MSR330P family includes different group configurations. The 440R-W23222 is specifically the Group 2 version.
In a multi-zone system, the selected group determines which safety output section the module serves. Correct group assignment is important when interpreting the wiring diagram, commissioning the machine, and troubleshooting unexpected shutdowns.
The 440R-W23222 is suitable for existing MSR300 installations where an additional Group 2 safety output module is required.
Automated Manufacturing Lines
Production equipment often contains multiple working areas with separate access points and stopping requirements. The module can provide output switching for a designated safety group.
Robotic Automation Cells
Robotic work cells may contain several controlled zones, including robot movement areas, material loading stations, and operator access sections. The MSR330P Group 2 module can form part of the overall safety output arrangement.
Conveyor and Material Handling Equipment
In large material handling systems, different conveyor sections may require separate safety stopping functions. Group-based output control helps organize these functions within a modular safety system.
Packaging Machinery
Packaging lines combine motors, actuators, guards, and automatic material movement. The module can be integrated into an MSR300 configuration to support the required safety output circuits.
Industrial Processing Equipment
Processing machinery may require coordinated shutdown functions across several operating sections. The 440R-W23222 can serve as an output component when the complete system is correctly configured and validated.
Installation should be carried out by qualified industrial electrical personnel. Since the 440R-W23222 is not a standalone safety relay, the existing MSR300 system configuration must be checked before installation.
Verify that the module is marked 440R-W23222 and identify it as the MSR330P Group 2 version. Do not substitute the Group 1 or Group 3 version without checking the original system design.
Confirm that the compatible MSR300 base and associated input modules are installed correctly. Inspect the modular interconnection and ensure that the output module is positioned in the intended Group 2 arrangement.
Mount the module securely on the designated DIN rail. Check the enclosure clearance and ensure that the removable terminal blocks can be accessed for inspection and maintenance.
Use the manufacturer’s terminal diagram to identify the output connections. The MSR330P output module uses terminals identified by the contact pairs 13–14, 23–24, and 33–34 for its three normally open safety outputs, with 41–42 associated with the normally closed auxiliary contact.
Verify the wiring against the exact system schematic before connecting external devices.
The reset arrangement is selected on the base module. Confirm that the configured reset behavior meets the machine’s safety requirements and that restart conditions cannot create unexpected machine movement.
Test each relevant safety input and verify the expected response of the Group 2 output circuits. Confirm that the connected contactors and external monitoring arrangements operate correctly.
Record the test results and validate the complete safety function before releasing the machine for production.
The 440R-W23222 is part of a safety-related control system. Maintenance should follow the machine’s documented inspection and validation procedures.
| Symptom | Possible Cause | Recommended Action |
|---|---|---|
| No safety output switching | Base module or system connection fault | Check base-unit status and modular connections |
| Group 2 does not respond | Incorrect group configuration | Verify module position and system wiring |
| One output circuit fails | Loose terminal or external circuit fault | Inspect the relevant contact pair and connected equipment |
| Auxiliary contact signal is incorrect | Contact wiring or monitoring circuit problem | Check terminals 41–42 and the external circuit |
| Intermittent operation | Poor terminal connection | Inspect removable terminal blocks |
| Module does not operate after replacement | Incorrect module version | Confirm Group 2 catalog number |
| Unexpected restart behavior | Reset configuration issue | Review base-module settings and machine control logic |
| Repeated safety faults | Fault elsewhere in the modular system | Inspect input modules, base unit, interconnections, and external devices |
Never bypass a safety output or defeat a protective function to keep machinery running. Any fault affecting a safety function must be investigated before the equipment returns to operation.
Rockwell Automation lists the 440R-W23222 as discontinued, effective February 28, 2022. The product is classified as an engineering replacement rather than a current-production module.
Rockwell’s migration documentation identifies the 440R-EMR2 and 440C-CR30-22BBB as replacement options for the MSR330P output-module family. The appropriate choice depends on the existing system architecture and required functions.
Before replacing the 440R-W23222, engineers should evaluate:
A replacement may require changes to wiring, configuration, or the overall safety design. It should not be treated as a direct plug-in substitute without engineering verification.
1. What is the Allen Bradley 440R-W23222?
It is a Guardmaster MSR330P Group 2 safety relay output module for the MSR300 modular safety relay family.
2. What is the difference between 440R-W23221 and 440R-W23222?
Both belong to the MSR330P family and provide three normally open safety outputs and one normally closed auxiliary output. The 440R-W23221 is Group 1, while the 440R-W23222 is Group 2.
3. How many safety outputs does the module have?
It has three normally open safety outputs.
4. Does the 440R-W23222 have an auxiliary contact?
Yes. It includes one normally closed auxiliary output.
5. Does this module have safety inputs?
No. It is an output module and has no direct safety inputs.
6. What power supply does it use?
It receives 24V DC operating power through the compatible MSR300 base-unit arrangement.
7. Can it operate as an independent safety relay?
No. It must be installed as part of a compatible MSR300 modular safety relay system.
8. How is the reset mode selected?
The reset configuration is selected on the base module rather than independently on the 440R-W23222.
9. Is the 440R-W23222 discontinued?
Yes. Rockwell Automation lists it as discontinued effective February 28, 2022.
10. What should be checked when replacing this module?
Check the output group assignment, base-unit compatibility, safety contact requirements, terminal wiring, reset behavior, and the complete machine safety design.
The Allen Bradley 440R-W23222 Guardmaster MSR330P Group 2 Safety Relay Output Module provides three normally open safety outputs and one normally closed auxiliary output for compatible MSR300 modular safety systems.
Its Group 2 configuration makes it suitable for installations that organize machine protection into multiple safety output zones. Although discontinued, it remains relevant to maintenance and spare-parts requirements for existing industrial equipment.
For replacement and system restoration projects, confirming the exact catalog number and original MSR300 configuration is essential to maintaining the intended safety functions.