Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen Bradley 440R-H23180 Guardmaster Minotaur MSR230P is a modular safety relay output expansion module designed for use with compatible Guardmaster Minotaur safety relay systems. It provides four normally open (NO) safety output contacts, allowing an existing safety control arrangement to expand the number of available safety switching circuits.
Unlike a standalone safety monitoring relay, the MSR230P does not independently monitor emergency-stop buttons, safety gates, or other safety input devices. It operates as an expansion module connected to a compatible base safety relay through the designated termination or expansion connection. Its operating power is supplied by the base unit through the module terminals.
The 440R-H23180 is particularly useful in machinery requiring additional safety outputs for external contactors, relays, solenoids, valves, or other compatible control components. Its compact 22.5 mm housing and removable terminal design support installation in industrial control cabinets.
| Parameter | Specification |
|---|---|
| Brand | Allen Bradley |
| Product Family | Guardmaster Minotaur |
| Model Number | 440R-H23180 |
| Relay Model | MSR230P |
| Product Type | Safety Relay Output Expansion Module |
| Module Function | Immediate Safety Output Expansion |
| Power Supply | 24V DC from compatible base unit |
| Independent Power Input | Not provided |
| Safety Inputs | None |
| Safety Outputs | 4 Normally Open (NO) |
| Auxiliary Outputs | None |
| Output Configuration | 4 immediate safety outputs |
| Reset Function | Controlled by the compatible base safety relay |
| Connection Type | Termination or expansion connection |
| Terminal Type | Removable terminals |
| Mounting | 35 mm DIN rail |
| Housing Width | 22.5 mm |
| Dimensions | 114.5 × 22.5 × 99 mm |
| Weight | 0.215 kg |
The main function of the MSR230P is to expand the safety output capacity of a compatible Guardmaster safety relay system.
It provides four normally open safety contacts:
These outputs are designed to switch together as part of the safety system’s operating sequence. They can be used in suitable arrangements to control external contactors, relays, solenoids, valves, and other machine-control devices.
The four additional outputs are particularly useful when a machine has multiple safety-related loads that must respond to the same safety control signal.
The 440R-H23180 is not a standalone safety monitoring device. It is designed to operate with a compatible Minotaur base safety relay.
The base relay monitors the connected safety devices and controls the expansion module through the designated termination or expansion connection. When the base system permits operation, the MSR230P provides its additional safety output contacts.
When the base safety system detects a safety condition requiring shutdown, the expansion outputs respond as part of the overall safety arrangement.
This modular architecture helps reduce the need for multiple independent safety relays when additional output contacts are required.
The MSR230P receives its 24V DC operating power from the compatible base safety relay through the designated terminals or connection arrangement.
It does not have an independent power supply input in the same way as a standalone safety relay. Therefore, the base unit and expansion connection must be verified before installation.
This is an important selection consideration when replacing an existing module or designing a new safety control cabinet.
The MSR230P provides four immediate safety outputs rather than delayed outputs. Its purpose is to extend the available switching capacity without introducing an additional timing function.
Applications requiring a defined delay before safety contacts change state need a suitable time-delay safety module rather than the MSR230P.
The Allen Bradley 440R-H23180 is suitable for industrial safety systems that require additional output contacts from a compatible Minotaur base relay.
Typical applications include:
The module must be used as part of a properly designed safety system. Its suitability depends on the base relay, connected loads, output contact ratings, and the machine’s required safety performance.
The MSR230P should be installed by qualified personnel familiar with industrial safety relay systems. Before installation, confirm that the existing base relay is compatible with the 440R-H23180.
Verify the catalog number and configuration of the existing Minotaur base relay. The MSR230P is an expansion module and cannot independently perform the complete safety monitoring function.
Check the manufacturer’s wiring documentation for the required termination or expansion cable arrangement.
Mount the module securely on a standard 35 mm DIN rail inside a suitable electrical enclosure.
Allow sufficient space for terminal access, wiring, ventilation, and future maintenance. Ensure that the module is firmly secured before connecting it to the system.
Connect the MSR230P to the compatible base unit using the specified termination or expansion connection.
Follow the official wiring diagram for the exact terminal arrangement. Do not assume that the connection method is interchangeable with other Minotaur expansion modules.
The module provides four normally open output contacts:
| Output | Terminal Pair |
|---|---|
| Safety Output 1 | 13–14 |
| Safety Output 2 | 23–24 |
| Safety Output 3 | 33–34 |
| Safety Output 4 | 43–44 |
Connect these contacts to the intended downstream control circuits according to the electrical design.
Check the contact ratings and load requirements before connecting external equipment. Use suitable protective devices and wiring methods for the application.
The MSR230P receives its operating power from the compatible base unit. Confirm that the base relay supplies the correct 24V DC through the specified connection.
Do not apply an independent supply to terminals unless the manufacturer’s documentation explicitly identifies them for that purpose.
After completing installation, inspect the wiring and verify the expansion module’s response to the base safety relay.
Test that all four outputs operate as intended when the base relay permits operation and return to the required safe state when the safety system is activated.
The complete machine safety function must be validated, including the base relay, expansion module, external contactors, wiring, and connected equipment.
Routine inspection can help identify connection problems and output faults before they affect machine operation.
| Problem | Possible Cause | Recommended Action |
|---|---|---|
| All four outputs remain open | Base safety relay is not permitting operation | Check the base relay status and safety input conditions |
| Expansion module does not operate | Incorrect expansion connection | Inspect the termination or expansion cable |
| No operating power | Base unit supply or connection problem | Verify the base relay’s 24V DC supply and module connection |
| One output does not switch | Wiring issue or damaged contact | Inspect the corresponding terminal pair and downstream circuit |
| External contactor does not energize | Incorrect output wiring or contactor fault | Check the output circuit, load, and contactor coil |
| Intermittent output operation | Loose terminal or unstable expansion connection | Inspect and secure all connections |
| Module fails after replacement | Incompatible base relay or incorrect wiring | Verify catalog numbers and the manufacturer’s compatibility information |
| Unexpected safety shutdown | Base relay detects a safety condition | Investigate the original safety input and base relay status |
The MSR230P should not be bypassed or modified to maintain machine operation. If an output fails to operate correctly, inspect the complete safety system and replace defective equipment with an approved compatible component.
1. What is the Allen Bradley 440R-H23180?
It is a Guardmaster Minotaur MSR230P safety relay output expansion module. It provides four additional normally open safety outputs for a compatible base safety relay system.
2. Is the MSR230P a standalone safety relay?
No. It is an expansion module and does not independently monitor emergency-stop buttons or safety gate inputs. It relies on a compatible base safety relay for its control signals.
3. How many safety outputs does the 440R-H23180 provide?
It provides four normally open safety outputs: 13–14, 23–24, 33–34, and 43–44.
4. What is the power supply requirement?
The module receives 24V DC operating power from the compatible base safety relay through the designated connection. It does not have an independent power input.
5. Does the MSR230P have safety input terminals?
No. The 440R-H23180 is designed for output expansion and does not provide independent safety input monitoring.
6. Does this module provide delayed safety outputs?
No. It provides four immediate safety outputs. Applications requiring delayed switching need a suitable time-delay safety module.
7. What devices can be controlled by its outputs?
Depending on the electrical design and contact ratings, its outputs can be used in suitable circuits involving external contactors, relays, solenoids, and valves.
8. How is the module mounted?
It is designed for installation on a standard 35 mm DIN rail inside an appropriate industrial control enclosure.
9. What should be checked if the four outputs do not operate?
Check the compatible base relay, its safety input conditions, the 24V DC supply arrangement, and the termination or expansion connection. Also inspect the output wiring and connected loads.
10. Is the 440R-H23180 still available as a current Rockwell Automation product?
No. Rockwell Automation lists the MSR230P as discontinued, with December 31, 2017 identified as its discontinuation date. The manufacturer identifies 440R-EM4R2 as an engineering replacement. Before substitution, verify the replacement’s compatibility with the existing safety architecture and wiring.
The Allen Bradley 440R-H23180 Guardmaster Minotaur MSR230P is a dedicated safety output expansion module designed to increase the number of available safety switching contacts in compatible industrial control systems. Its four normally open immediate safety outputs, 24V DC supply from the base unit, and compact DIN rail design make it suitable for machinery requiring additional safety-controlled circuits.
Because this module depends on a compatible base safety relay, correct system identification is essential during installation and replacement. Confirming the expansion connection, output configuration, and replacement compatibility helps maintain the intended safety functions of the machine.