• Honeywell FS-CCI-HSE-01 Ethernet Cable Kit
  • Honeywell FS-CCI-HSE-01 Ethernet Cable Kit
  • Honeywell FS-CCI-HSE-01 Ethernet Cable Kit
  • Honeywell FS-CCI-HSE-01 Ethernet Cable Kit
Product Overview The Honeywell FS-CCI-HSE-01 Ethernet Cable Kit is an industrial communication cable assembly designed for use with compatible Honeywell Safety Manager control system equipment. It provi……
Honeywell FS-CCI-HSE-01 Ethernet Cable Kit
  • Honeywell
  • FS-CCI-HSE-01
  • Ethernet Cable Kit
  • USA
  • 3 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Honeywell FS-CCI-HSE-01 Ethernet Cable Kit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell FS-CCI-HSE-01 Ethernet Cable Kit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell FS-CCI-HSE-01 Ethernet Cable Kit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell FS-CCI-HSE-01 Ethernet Cable Kit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Honeywell FS-CCI-HSE-01 Ethernet Cable Kit is an industrial communication cable assembly designed for use with compatible Honeywell Safety Manager control system equipment. It provides a physical Ethernet connection between supported communication interfaces and helps establish reliable data links within industrial automation networks.

In industrial control environments, communication cables are essential for connecting controllers, communication interfaces, and other network components. Stable physical connections are particularly important in process automation and safety-related installations, where communication interruptions can affect system monitoring, diagnostics, and data exchange.

The FS-CCI-HSE-01 uses CAT5PLUS STP (Shielded Twisted Pair) cable construction. Its shielding helps reduce the effects of electromagnetic interference generated by nearby motors, drives, switching equipment, and other electrical devices. This makes the cable suitable for applications where network wiring must operate in an electrically demanding industrial environment.

The cable set has a specified length of 3 meters per cable and uses RJ45 connectors at both ends. The assembly includes green and yellow cable connectors, providing a predefined connection arrangement for compatible Honeywell equipment.

This product is identified by the catalog number FS-CCI-HSE-01. It is intended for installations where the corresponding Honeywell communication cable assembly is specified. Before ordering, engineers should verify the cable model, connector arrangement, cable length, and compatibility with the installed Safety Manager hardware.

Technical Specifications

Parameter Specification
Brand Honeywell
Model FS-CCI-HSE-01
Product Type Ethernet Cable Kit
Application Industrial Communication
Compatible Platform Honeywell Safety Manager System
Cable Type CAT5PLUS STP
Cable Construction Shielded Twisted Pair
Cable Length 3 meters per cable
Connector Type RJ45
Connector Configuration RJ45 at both ends
Cable Set 1 Green Connector, 1 Yellow Connector
Approvals UL, CSA, FM
Shipping Weight 3 kg
Net Cable Weight Not specified
Typical Application Industrial Ethernet and control system communication

Note: The 3 kg figure is the supplied shipping weight, not a confirmed cable-only weight. Actual packaging dimensions and shipment weight should be checked before logistics arrangements.

Function and Working Principle

The FS-CCI-HSE-01 provides the physical communication connection required for compatible industrial Ethernet interfaces. It does not process control logic or perform signal conversion. Instead, it carries digital communication signals between connected devices.

1. Ethernet Data Transmission

Ethernet communication allows compatible automation devices to exchange digital information through a network connection.

The FS-CCI-HSE-01 provides the physical cable path for this communication. When connected to supported interfaces, it can help establish a data link between equipment within the Honeywell control system architecture.

The actual communication protocol and network configuration depend on the connected equipment.

2. Shielded Twisted-Pair Construction

The cable uses CAT5PLUS STP construction. Its twisted-pair conductors support Ethernet signal transmission, while the shielding helps reduce electromagnetic interference.

Industrial environments often contain electrical noise from variable frequency drives, motors, contactors, transformers, and switching power supplies. Properly installed shielded cable can help reduce the effects of this interference on communication signals.

Shielding performance also depends on correct connector termination, grounding practices, and cable routing.

3. RJ45 Connector Interface

The FS-CCI-HSE-01 uses RJ45 connectors at both ends. This provides a standardized physical connection for compatible Ethernet ports.

The preassembled connectors simplify installation compared with preparing and terminating individual cable ends in the field.

Before connecting the cable, technicians should verify the port assignment and ensure that the cable is being installed between the interfaces specified by the system documentation.

4. Defined Cable Length

The cable set has a specified length of 3 meters per cable. This length is suitable for certain local equipment connections where devices are installed relatively close to each other.

Using the specified cable length can help maintain an organized control cabinet and avoid unnecessary cable loops or excessive wiring.

5. Color-Coded Connection Arrangement

The set includes green and yellow cable connectors. These provide a defined physical identification arrangement for the intended installation.

Technicians should follow the equipment documentation when assigning the connectors to individual ports. Color alone should not be used to determine network function or connection priority.

Role in Industrial Control Systems

The FS-CCI-HSE-01 supports the communication infrastructure of compatible Honeywell automation systems. Its role is to provide the physical network connection required for communication between designated system interfaces.

Safety Manager System Connectivity

Honeywell Safety Manager systems are designed for industrial applications that require safety-related monitoring and control functions.

Communication infrastructure is an important part of these installations. The FS-CCI-HSE-01 can be used where this specific cable set is required by the system hardware configuration.

Correct cable identification is important because safety-related installations may have specific hardware and wiring requirements.

Controller Communication

Industrial controllers exchange information with other control system components through defined communication interfaces.

The cable provides the physical connection between compatible Ethernet ports. The controller and connected equipment determine the communication protocol, data structure, and network behavior.

The cable itself does not provide controller functionality or guarantee that two devices are logically compatible.

Network Infrastructure

The FS-CCI-HSE-01 can form part of the physical cabling arrangement inside an industrial control cabinet or equipment enclosure.

A properly organized network infrastructure helps maintenance personnel identify connections, inspect wiring, and troubleshoot communication problems.

Maintenance and Replacement

When an existing cable becomes damaged, worn, or unreliable, replacing it with the correct catalog-number assembly can help restore the intended physical connection.

Using the exact model is particularly important when the cable belongs to a predefined Honeywell hardware configuration.

Industrial Applications

1. Process Automation Systems

Process automation installations use communication networks to connect controllers and other system components.

The FS-CCI-HSE-01 may be used in compatible Honeywell Safety Manager installations where a 3-meter Ethernet cable assembly is specified.

2. Industrial Safety Systems

Safety-related automation systems require carefully managed hardware configurations and communication connections.

The cable can support the physical communication infrastructure of compatible Safety Manager equipment. Its use must follow the system’s approved hardware and installation documentation.

3. Control Cabinet Networking

Industrial control cabinets frequently contain controllers, communication interfaces, power supplies, and other automation components.

A short Ethernet cable assembly can provide a practical connection between equipment installed within the same cabinet or nearby enclosures.

4. Manufacturing Facilities

Manufacturing facilities rely on communication connections between automation equipment to support monitoring, diagnostics, and coordinated operation.

The FS-CCI-HSE-01 can be used in compatible Honeywell installations where the specified cable assembly is required.

5. Industrial Equipment Maintenance

Maintenance teams may need to replace damaged or aging network cables during scheduled maintenance or equipment repair.

Using the correct cable model and connector arrangement helps avoid unnecessary modifications to the existing wiring configuration.

6. Distributed Control Environments

Industrial facilities may use distributed automation equipment installed across multiple cabinets and control locations.

The FS-CCI-HSE-01 can support local Ethernet connections within a larger communication architecture, provided the connected hardware is compatible.

Installation and System Integration

Correct installation is essential for maintaining communication reliability and avoiding unnecessary network faults.

1. Verify the Cable Model

Before installation, confirm that the cable label identifies FS-CCI-HSE-01.

Do not select a replacement based only on its appearance or the fact that it has RJ45 connectors. Different Honeywell cable assemblies may have different lengths, connector arrangements, or intended applications.

2. Confirm Connector Assignment

The cable set includes green and yellow connectors. Check the Honeywell system documentation to determine the correct connection points.

Avoid changing the intended connection arrangement without confirming the system requirements.

3. Inspect RJ45 Connectors

Before connecting the cable, inspect both RJ45 connectors for damaged locking tabs, bent contacts, contamination, or other physical defects.

A loose or damaged connector can cause intermittent communication problems even when the cable itself appears undamaged.

4. Route the Cable Properly

Keep communication cables separated from high-voltage power wiring and other potential sources of electrical interference where required.

Avoid sharp bends, excessive pulling force, crushing, and unnecessary tension. Follow the manufacturer’s cable-routing recommendations.

5. Maintain Shielding Integrity

Because the FS-CCI-HSE-01 uses shielded twisted-pair construction, its shielding arrangement should be maintained during installation.

Do not cut, modify, or reterminate the cable unless the applicable installation documentation permits it. Incorrect shield handling can reduce its ability to resist electromagnetic interference.

6. Verify Communication After Installation

After connecting the cable, check the relevant system indicators and communication diagnostics.

Confirm that the connected devices are recognized and that the expected communication status is restored. If communication problems remain, inspect the cable connections, port assignments, network configuration, and connected hardware.

7. Follow Safety Procedures

When working inside industrial control cabinets, follow the site’s electrical safety procedures and equipment isolation requirements.

For safety-related control equipment, installation and replacement should be performed by qualified personnel familiar with the system configuration.

Compatible System Components

The FS-CCI-HSE-01 is a communication accessory rather than an independent control device. Its suitability depends on the interfaces and equipment specified for the installation.

Component Function Integration Considerations
Honeywell Safety Manager equipment Provides safety-related control functionality Verify the exact hardware connection requirements
Ethernet communication interface Provides a network connection Confirm RJ45 interface compatibility
Industrial controller Executes control and monitoring functions Check the intended communication architecture
Industrial Ethernet network Transfers digital information between devices Confirm network configuration and supported communication requirements
Control cabinet Houses automation equipment Maintain suitable cable routing and separation
RJ45 interface ports Provide physical Ethernet connections Inspect connectors and port assignments
Shielded cable accessories Support shield continuity and installation Follow applicable grounding and shielding instructions

The table describes typical system components and integration considerations. It does not mean that these components are included in the FS-CCI-HSE-01 cable kit.

Alternative Models and Replacement Considerations

When replacing the FS-CCI-HSE-01, the safest approach is to identify the exact original catalog number and confirm the cable requirements in the installed Honeywell system.

Alternative or Related Product Replacement Considerations
Honeywell FS-CCI-HSE-02 Related Honeywell Ethernet cable set; verify the intended application and connector configuration
Honeywell FS-CCI-HSE-20 Different cable-set designation; confirm length and hardware compatibility
Honeywell FS-CCI-HSE-30 Related cable assembly; not automatically interchangeable
Honeywell 51305482-202 Another Honeywell Ethernet cable assembly; verify system-specific use
Standard CAT5PLUS STP cable Similar cable construction does not guarantee compatibility with the original assembly
Standard RJ45 Ethernet patch cable May have different shielding, connector details, and approval requirements

Before choosing an alternative, check:

  • Exact Honeywell catalog number.
  • Cable type and shielding construction.
  • Cable length.
  • RJ45 connector arrangement.
  • Connector color identification.
  • Intended Safety Manager hardware interfaces.
  • Applicable approvals and installation requirements.
  • Environmental and routing conditions.

A standard Ethernet patch cable should not automatically be considered a direct substitute. The original cable assembly may have been selected for a particular system connection and installation requirement.

Key Advantages

Shielded Communication Cable

The CAT5PLUS STP construction provides shielding that helps reduce the effects of electromagnetic interference in industrial environments.

Standard RJ45 Connections

RJ45 connectors at both ends provide a familiar physical Ethernet interface for compatible equipment.

Preassembled Cable Kit

The cable assembly is supplied with its connectors installed, reducing the need for field termination.

Defined 3-Meter Length

The specified cable length supports short-distance connections between compatible automation components.

Color-Coded Connectors

The green and yellow connectors provide a defined identification arrangement for the intended system installation.

Industrial System Application

The cable is designed for use in compatible Honeywell Safety Manager communication configurations.

Recognized Approvals

The documented UL, CSA, and FM approvals support applications where these approvals are required by the equipment specification.

Replacement Convenience

Using the original catalog number helps maintenance teams identify the intended cable assembly when servicing existing Honeywell control systems.

Technical FAQs

1. What is the Honeywell FS-CCI-HSE-01?

The FS-CCI-HSE-01 is a Honeywell Ethernet communication cable kit designed for compatible Safety Manager system installations. It provides the physical cable connection between designated communication interfaces.

2. What is the cable length?

The specified length is 3 meters per cable.

3. What type of cable does it use?

It uses CAT5PLUS STP, which stands for Shielded Twisted Pair. This construction includes shielding intended to help reduce electromagnetic interference.

4. What connectors are installed?

The cable uses RJ45 connectors at both ends.

5. What is included in the cable set?

The documented set includes one cable connector identified as green and one identified as yellow. Confirm the delivered contents against the supplier’s packing information.

6. Is the FS-CCI-HSE-01 suitable for Honeywell Safety Manager systems?

It is documented as a communication cable for Honeywell Safety Manager hardware. The exact connection points should be confirmed using the system hardware documentation.

7. What approvals are associated with this model?

The documented approvals include UL, CSA, and FM.

8. Can it be replaced with a standard Ethernet cable?

Not automatically. A standard cable may have different shielding, connector construction, approvals, or installation characteristics. Verify compatibility before using an alternative.

9. What is the purpose of the shielded twisted-pair construction?

The shielding helps reduce the effects of electromagnetic interference on communication signals. Proper installation and shielding practices are still necessary.

10. Is the 3 kg weight the cable’s net weight?

No. The supplied 3 kg figure is identified as shipping weight. The actual cable-only weight has not been independently confirmed and should be listed separately if required.

Procurement and Maintenance Recommendations

When purchasing the Honeywell FS-CCI-HSE-01 Ethernet Cable Kit, verify the full model number and confirm that the cable is intended for the specific Honeywell Safety Manager configuration.

Check the cable length, CAT5PLUS STP construction, RJ45 connectors, and green/yellow connector arrangement. These details are important when replacing an existing cable or maintaining a predefined control system wiring configuration.

For industrial spare-parts procurement, request clear product photographs and confirm the delivered cable set includes the correct connectors. If the product is supplied as new or unused stock, verify its physical condition and packaging before installation.

During maintenance, inspect the cable jacket, connector locking tabs, contacts, and connection points. Replace cables showing physical damage, loose connectors, or signs of deterioration.

Keep network cables organized and clearly identified inside control cabinets. Avoid excessive bending, tension, and contact with high-temperature or high-interference equipment.

The supplied shipping weight is 3 kg. For international shipping, confirm the packed dimensions and actual gross weight with the supplier before calculating freight charges.

Conclusion

The Honeywell FS-CCI-HSE-01 Ethernet Cable Kit is a 3-meter CAT5PLUS STP communication cable assembly designed for compatible Honeywell Safety Manager systems. It features RJ45 connectors at both ends, a green and yellow connector arrangement, and documented UL, CSA, and FM approvals.

Its shielded twisted-pair construction supports Ethernet communication in industrial environments where electrical interference must be considered. For maintenance and replacement projects, verifying the exact catalog number, connector arrangement, and system compatibility is essential to maintaining reliable communication connections.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501