The Siemens 6AG2155-5AA00-1AC0 SIPLUS ET 200MP IM155-5 PN HF Interface Module is a high-feature PROFINET interface module designed for distributed I/O systems in industrial automation. It connects ET 200MP electronic modules to a PROFINET-based controller, enabling distributed input and output signals to be exchanged with the central automation system.
As part of the Siemens SIPLUS product family, this module is based on the standard SIMATIC ET 200MP interface module 6ES7155-5AA00-0AC0 and incorporates additional environmental protection. Its conformal coating and extended temperature capability make it suitable for demanding industrial conditions where standard automation components may require additional environmental protection.
The module acts as the communication and station-management interface for an ET 200MP distributed I/O station. It provides a PROFINET IO device connection, an integrated two-port switch, and support for network functions such as Media Redundancy Protocol (MRP) and Isochronous Real-Time (IRT). These capabilities allow the distributed I/O station to exchange process data with a compatible PROFINET controller while supporting different network architectures.
The 6AG2155-5AA00-1AC0 can support up to 12 I/O modules without an additional system power supply. With an additional power supply installed, the station can accommodate up to 30 I/O modules, subject to the system configuration and power-segment limitations.
This interface module is particularly relevant to installations requiring distributed I/O, high-speed communication, synchronized data exchange, and enhanced environmental resistance. It can be used in manufacturing facilities, process automation systems, transportation-related equipment, and other industrial environments where reliable communication between field-level devices and a central controller is essential.
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Product Family | SIPLUS ET 200MP |
| Model | 6AG2155-5AA00-1AC0 |
| Product Type | PROFINET Interface Module |
| Interface Module | IM 155-5 PN HF T1 RAIL |
| Base Product | 6ES7155-5AA00-0AC0 |
| Communication Protocol | PROFINET IO |
| Network Interface | Integrated 2-port switch |
| Physical Connection | RJ45 Ethernet |
| Network Speed | 100 Mbps |
| Media Redundancy | MRP supported |
| Real-Time Communication | IRT supported |
| Minimum IRT Cycle | 250 μs |
| Supply Voltage | 24 V DC |
| Permissible Voltage Range | 19.2–28.8 V DC |
| Rated Current Consumption | 0.2 A |
| Maximum Current Consumption | 1.2 A |
| Maximum Inrush Current | 9 A |
| I/O Modules Without Additional PS | Up to 12 |
| I/O Modules With Additional PS | Up to 30 |
| Maximum Power Segments | 3 |
| Maximum Address Space Per Module | 256 bytes input / 256 bytes output |
| Maximum Address Space Per Station | 512 bytes input / 512 bytes output |
| Environmental Protection | Conformal coating |
| Operating Temperature | -40 to +60 °C, according to the SIPLUS T1 configuration |
| Dimensions | 35 × 147 × 129 mm |
| Weight | 0.356 kg |
| Typical Application | Distributed I/O and PROFINET automation systems |
Technical specifications should be checked against the exact hardware revision and Siemens configuration documentation before system design or replacement.
The primary function of the 6AG2155-5AA00-1AC0 is to provide the communication interface between an ET 200MP distributed I/O station and a PROFINET controller. It manages the exchange of process data and diagnostic information between the distributed station and the automation system.
PROFINET is an Industrial Ethernet communication standard used to connect controllers, distributed I/O stations, drives, and other automation devices.
The 6AG2155-5AA00-1AC0 operates as a PROFINET IO device. It receives configuration information and communication parameters from the engineering environment and exchanges input and output data with the assigned PROFINET controller.
In a typical installation, field sensors connect to input modules installed in the ET 200MP station. The interface module transfers the acquired input data through the PROFINET network to the controller. Output commands from the controller are then delivered to the corresponding output modules.
This arrangement allows I/O equipment to be installed near the machinery or process area instead of routing every field signal directly to a central PLC cabinet.
The module incorporates a two-port Ethernet switch with RJ45 connections. This supports flexible network wiring and can simplify the connection of distributed automation equipment.
For example, a PROFINET network cable can connect the interface module to an upstream network device, while the second port can connect another compatible device in the network topology.
The integrated switch can reduce the need for an additional external switch in certain configurations. However, network planning must still account for topology, cable length, device limits, and the requirements of the selected PROFINET architecture.
The module supports Media Redundancy Protocol (MRP), which is used in suitable Ethernet ring networks to improve communication availability.
In an MRP configuration, network devices are connected in a ring. If a cable or network connection is interrupted, the redundancy mechanism can reconfigure communication through the remaining network path.
This function is useful in industrial systems where a communication interruption may affect production or process monitoring.
MRP operation requires compatible network devices and correct configuration. The interface module alone does not provide complete network redundancy without an appropriately designed ring topology.
The 6AG2155-5AA00-1AC0 supports IRT communication with a minimum isochronous cycle of 250 μs under the specified system conditions.
IRT is designed for applications requiring predictable communication timing. It can help synchronize data exchange between compatible controllers and field devices.
This capability is particularly relevant to high-speed production processes, coordinated machinery, and applications where timing consistency is important.
Actual cycle performance depends on the controller, network configuration, connected devices, and engineering parameters.
The interface module manages communication with the electronic modules installed in the ET 200MP station.
It allows different I/O modules to operate as part of one distributed station. These modules may provide digital input, digital output, analog input, analog output, or other supported functions.
The interface module also supports station diagnostics and identification data, helping engineering and maintenance personnel identify the installed hardware and monitor system status.
The SIPLUS configuration includes conformal coating to provide additional protection for electronic assemblies under demanding environmental conditions.
Its extended temperature specification supports operation in environments where standard industrial modules may not be suitable. The module is also designed for applications involving more demanding environmental conditions, including certain railway and industrial environments.
Conformal coating does not eliminate the need for proper installation, enclosure design, grounding, and compliance with the manufacturer’s environmental limitations.
The 6AG2155-5AA00-1AC0 serves as an important communication component in distributed automation architectures. It connects field-level I/O modules to the central control system and enables process signals to be exchanged through PROFINET.
The module is designed for use within the Siemens SIMATIC automation ecosystem. A compatible SIMATIC controller can communicate with the ET 200MP station through PROFINET.
The engineering environment is used to configure the interface module, assign its network parameters, select the installed I/O modules, and establish the station’s process data structure.
This configuration allows the controller to access distributed input and output signals as part of the overall automation program.
In a centralized I/O architecture, field signals may need to be routed over long distances to a main control cabinet. Distributed I/O provides another approach by placing signal modules closer to sensors and actuators.
The 6AG2155-5AA00-1AC0 provides the network connection for this arrangement. Sensors and actuators connect to the appropriate ET 200MP electronic modules, while the interface module communicates with the controller.
This can simplify field wiring and make it easier to organize large installations into separate machine or process areas.
The interface module supports diagnostic information that helps maintenance personnel identify communication problems and station-related faults.
Status indicators can provide information about operating conditions, network communication, and diagnostic states. These indicators help technicians narrow down potential problems before investigating individual I/O channels or field devices.
The module’s integrated two-port switch supports connection to compatible PROFINET network devices. Depending on the network design, the station can be connected through a line or ring topology.
When redundancy is required, MRP can be incorporated into the network design using compatible switches and devices.
For synchronized communication requirements, IRT can be configured as part of a suitable PROFINET system.
The 6AG2155-5AA00-1AC0 is suitable for distributed I/O installations that require PROFINET communication and enhanced environmental resistance.
Manufacturing lines often contain multiple machines, sensors, actuators, and control stations. Distributed I/O helps connect these field devices to the central PLC without requiring all signal cables to return to one cabinet.
The interface module can manage an ET 200MP station installed near a production machine, allowing digital and analog signals to be exchanged with the central controller.
Typical applications include assembly lines, material handling, machine monitoring, and automated production equipment.
Industrial process systems use distributed sensors and actuators to monitor and control operating conditions.
The ET 200MP station can collect signals from instruments such as pressure transmitters, temperature sensors, level switches, and flow-measurement devices through compatible I/O modules.
The interface module transfers this information to the controller through PROFINET, allowing the automation system to execute control logic and monitor process conditions.
The SIPLUS T1 RAIL configuration is designed for demanding railway-related environments. Its environmental protection and temperature capabilities make it relevant to suitable railway automation and vehicle-related control installations.
Potential applications include auxiliary equipment monitoring, distributed signal acquisition, and control-system interfaces.
Railway installations must still meet the applicable standards and environmental requirements for the complete system. The suitability of the module should be evaluated within the overall equipment design.
Some industrial facilities operate in environments where temperature variation, condensation, corrosive substances, or contamination may affect electronic equipment.
The SIPLUS configuration provides additional environmental protection compared with a standard module. It can therefore be considered for suitable installations where environmental conditions are more demanding.
The actual installation must remain within the specified operating limits and follow the manufacturer’s guidance for enclosure protection and mounting orientation.
Applications involving coordinated machinery may require predictable communication timing between controllers and distributed devices.
The module’s IRT support makes it suitable for consideration in compatible systems requiring synchronized data exchange.
The final performance depends on the complete PROFINET network, controller capabilities, engineering configuration, and connected equipment.
The ability to support up to 30 I/O modules with an additional system power supply makes the interface module relevant to larger distributed stations.
This can help consolidate field signals from different parts of a machine or production area into one managed ET 200MP station.
The station must be designed according to the module count, power-segment limits, backplane power requirements, and the electrical characteristics of the selected I/O modules.
Correct installation and configuration are essential for reliable communication and stable operation.
Before installation, confirm that the module is the SIPLUS 6AG2155-5AA00-1AC0 rather than a visually similar standard ET 200MP interface module.
This model is based on 6ES7155-5AA00-0AC0 but has a SIPLUS environmental protection configuration. Substituting a standard module without checking the environmental requirements may affect system suitability.
Also verify the hardware revision and compatibility with the selected ET 200MP modules and controller.
The supplied dimensions are 35 × 147 × 129 mm, and the weight is 0.356 kg.
Install the interface module in the appropriate ET 200MP mounting arrangement. Ensure that the mounting position, mechanical engagement, and adjacent module connections follow the system installation instructions.
Allow adequate access for wiring, module replacement, and inspection of status indicators.
The module uses a nominal 24 V DC supply. The specified permissible voltage range is 19.2–28.8 V DC.
Before connecting the supply, verify polarity, supply capacity, grounding, and wiring integrity. The power source should be suitable for the connected station and its expected load.
Avoid using an undersized power supply, particularly when the station contains several electronic modules or additional power segments.
Use compatible Ethernet cabling and connectors for the PROFINET connection.
Connect the module to the intended network according to the planned topology. Verify the correct port connections, cable routing, shielding, and grounding practices.
After wiring, inspect the network connections and confirm that the expected link indicators are active.
The module must be configured in a compatible Siemens engineering environment.
The typical configuration process includes:
The engineering software version and device support package should be checked before commissioning.
If the installation uses an MRP ring, confirm that the connected network devices support the required redundancy functions.
Assign the correct MRP roles and verify the ring configuration. Test the network response under controlled conditions before returning the production system to normal operation.
After configuration, check the module’s status indicators and the controller’s diagnostic information.
Verify that the station is recognized, all installed I/O modules are available, and process data is exchanged correctly.
Test representative input and output channels to confirm signal mapping and field wiring. Record the final configuration for future maintenance.
The 6AG2155-5AA00-1AC0 is designed for use with compatible Siemens ET 200MP and PROFINET system components.
| Component | Function | Integration Considerations |
|---|---|---|
| Siemens SIMATIC S7-1500 PLC | Main automation controller | Confirm PROFINET controller compatibility and engineering configuration |
| Siemens SIMATIC S7-400H | Redundant controller architecture | Verify supported S2 redundancy and system configuration |
| ET 200MP I/O modules | Digital and analog signal processing | Check module compatibility, station limits, and power requirements |
| Siemens system power supply | Provides power for additional station segments | Required when expanding the station beyond the basic module capacity |
| PROFINET industrial Ethernet cable | Connects the distributed station to the network | Use suitable industrial Ethernet cabling and installation practices |
| Managed PROFINET switch | Network distribution and redundancy support | Confirm MRP and IRT requirements where applicable |
| 24 V DC power supply | Provides operating power | Verify voltage range and sufficient current capacity |
| TIA Portal | Hardware configuration and engineering | Check the supported software version and device description |
| Sensors and transmitters | Provide field measurement signals | Connect through compatible ET 200MP input modules |
| Actuators and control devices | Receive output commands | Use suitable output modules and field wiring |
These components are examples of equipment used in a complete ET 200MP installation. They are not necessarily supplied with the interface module.
When replacing the 6AG2155-5AA00-1AC0, engineers should distinguish between standard ET 200MP interface modules and SIPLUS variants.
| Model | Product Description | Replacement Considerations |
|---|---|---|
| 6ES7155-5AA00-0AC0 | SIMATIC ET 200MP IM 155-5 PN HF | Standard base product; does not automatically provide the same SIPLUS environmental protection |
| 6ES7155-5AA01-0AB0 | SIMATIC ET 200MP IM 155-5 PN ST | Different feature level; verify communication and station requirements |
| 6ES7155-5AA00-0AA0 | SIMATIC ET 200MP IM 155-5 PN BA | Different interface-module feature set; check compatibility before substitution |
| 6AG2155-5AA01-4AB0 | SIPLUS ET 200MP IM 155-5 PN ST TX RAIL | Another SIPLUS railway-oriented interface option with different specifications |
| 6AG1155-5AA00-2AC0 | SIPLUS ET 200MP IM 155-5 PN HF | Related SIPLUS interface module; verify the exact environmental and system configuration |
A replacement should be evaluated using the following criteria:
A standard ET 200MP interface module may provide similar communication functions but should not be assumed to offer the same environmental protection as the SIPLUS version.
The SIPLUS configuration incorporates conformal coating and an extended environmental specification. This makes it suitable for selected installations where standard industrial modules may require additional protection.
The module supports PROFINET IO communication and provides a high-feature interface for distributed ET 200MP stations.
The built-in switch simplifies network connections and supports flexible industrial Ethernet topologies.
MRP support allows the module to participate in compatible ring networks designed to improve communication availability.
The module supports isochronous real-time communication for applications requiring predictable data-exchange timing.
The module supports up to 12 I/O modules without an additional system power supply and up to 30 with an additional power supply, subject to system configuration.
Status and diagnostic functions help maintenance personnel identify communication and station-related problems.
With dimensions of 35 × 147 × 129 mm and a weight of 0.356 kg, the module provides a compact interface for distributed I/O installations.
It is a SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL PROFINET interface module. It connects ET 200MP electronic I/O modules to a PROFINET controller.
The 6AG2155-5AA00-1AC0 is the SIPLUS version based on the standard 6ES7155-5AA00-0AC0. It includes conformal coating and an extended environmental specification intended for more demanding operating conditions.
It supports PROFINET IO device communication. It also supports functions including MRP media redundancy and IRT isochronous real-time communication.
The station can support up to 12 I/O modules without an additional system power supply. With an additional power supply, the station can support up to 30 I/O modules, subject to system configuration and power requirements.
It uses a nominal 24 V DC supply, with a specified permissible range of 19.2–28.8 V DC.
Yes. It includes an integrated two-port switch with RJ45 Ethernet connections, supporting flexible PROFINET network wiring.
MRP is a network media-redundancy protocol. In a compatible ring topology, it helps maintain communication when a network connection is interrupted.
IRT provides predictable communication timing for compatible automation systems. It is useful in applications requiring synchronized data exchange between controllers and distributed devices.
The SIPLUS T1 RAIL version is designed for suitable railway-related environments and includes enhanced environmental protection. The complete installation must still meet the applicable railway standards and system requirements.
Verify the complete order number, environmental requirements, PROFINET functions, I/O station configuration, controller compatibility, power-segment design, and firmware requirements. A standard ET 200MP interface module should not be substituted without evaluating the environmental protection differences.
When purchasing the Siemens 6AG2155-5AA00-1AC0, verify the full order number and confirm that the product is the SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL version. This is particularly important when replacing equipment in installations that depend on enhanced environmental protection.
For new, surplus, or refurbished units, inspect the product label, housing, connectors, and mounting interfaces. Confirm the hardware revision and request appropriate product documentation where available. The supplied dimensions of 35 × 147 × 129 mm and weight of 0.356 kg can be used as listing information, but actual shipping measurements should be confirmed separately.
During installation, verify the 24 V DC supply, PROFINET cable connections, module arrangement, and environmental conditions. Ensure that the cabinet or equipment enclosure provides suitable protection and that the module is operated within its specified limits.
For routine maintenance, monitor the RUN, ERROR, MAINT, and network status indicators. Review controller diagnostics when communication faults occur. Check Ethernet connectors, cable condition, station power, and the configuration of connected I/O modules.
When expanding an ET 200MP station, calculate the power requirements of the connected modules and determine whether an additional system power supply is required. Do not exceed the supported module count or power-segment limits.
The Siemens 6AG2155-5AA00-1AC0 SIPLUS ET 200MP IM155-5 PN HF Interface Module is a high-feature PROFINET interface designed for distributed I/O applications requiring reliable communication and enhanced environmental protection.
Its integrated two-port switch, MRP support, IRT capability, expandable station architecture, and conformal coating make it suitable for selected industrial and railway-related automation installations. By connecting ET 200MP electronic modules to a PROFINET controller, it supports distributed signal acquisition, process monitoring, and coordinated machine control.
For procurement, installation, and replacement projects, engineers should verify the exact SIPLUS catalog number, environmental requirements, controller compatibility, I/O configuration, and power-supply arrangement. These checks help ensure that the interface module operates correctly within the intended automation system.