• ABB PST300-600-70 1SFA894014R7000 Soft Starter
  • ABB PST300-600-70 1SFA894014R7000 Soft Starter
  • ABB PST300-600-70 1SFA894014R7000 Soft Starter
  • ABB PST300-600-70 1SFA894014R7000 Soft Starter
Applications The ABB PST300-600-70 Soft Starter is designed for controlling the starting and stopping of large three-phase AC motors in industrial environments. With a rated operational current of 300 A……
ABB PST300-600-70 1SFA894014R7000 Soft Starter
  • ABB
  • PST300-600-70 1SFA894014R7000
  • Soft Starter
  • Sweden (SE)
  • 420 x 270 x 360 mm
  • 23 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 38

Our advantage

ABB PST300-600-70 1SFA894014R7000 Soft Starter

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

ABB PST300-600-70 1SFA894014R7000 Soft Starter

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

ABB PST300-600-70 1SFA894014R7000 Soft Starter

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

ABB PST300-600-70 1SFA894014R7000 Soft Starter

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Applications

The ABB PST300-600-70 Soft Starter is designed for controlling the starting and stopping of large three-phase AC motors in industrial environments. With a rated operational current of 300 A for in-line connection and a main circuit voltage range of 208–600 V AC, it is suitable for demanding motor-driven equipment where controlled acceleration and deceleration are important.

Unlike direct-on-line starting, which applies full supply voltage to the motor immediately, a soft starter gradually increases the voltage supplied to the motor during startup. This helps reduce starting current and mechanical shock, supporting smoother operation of connected machinery.

The PST300-600-70 can be used in a range of industrial applications.

1. Industrial Pumping Systems

Large pumps often experience significant mechanical stress during starting and stopping. Sudden changes in motor torque can contribute to pressure fluctuations, water hammer, and unnecessary stress on pipelines and mechanical connections.

The PST300-600-70 provides adjustable starting and stopping control, helping operators manage motor acceleration and deceleration according to system requirements. It is suitable for appropriately rated industrial water pumps, process pumps, and circulation systems.

2. Industrial Fans and Ventilation Equipment

Large ventilation fans and industrial blowers may require substantial starting torque and current. A soft starter helps manage the electrical and mechanical effects associated with motor startup.

The PST300-600-70 can be applied to compatible fan motors in manufacturing facilities, industrial ventilation systems, and process-air installations.

3. Compressors

Industrial compressors frequently operate with substantial motor loads. Controlled starting can help reduce the impact of motor startup on the electrical distribution system and connected mechanical equipment.

When applying this soft starter to a compressor, engineers should verify the compressor’s unloading arrangement, starting torque requirements, motor current, and permitted starting frequency.

4. Conveyor Systems

Large conveyors used in mining, manufacturing, and material handling can experience considerable mechanical stress during startup.

The PST300-600-70 can help provide smoother motor acceleration, reducing abrupt torque changes that may affect belts, couplings, gearboxes, and transported materials.

5. Industrial Processing Machinery

The soft starter can also be used in suitable industrial machinery where large three-phase motors require controlled starting and stopping.

Typical examples include selected mixers, crushers, production-line equipment, and other motor-driven systems. Final selection must consider the motor’s rated current, load characteristics, starting duration, and operating cycle.

Advantages

1. High Current Capacity

The PST300-600-70 has a rated operational current of 300 A for in-line connection. This makes it suitable for large industrial motor-control installations when the application falls within its electrical and thermal ratings.

For inside-delta connection, the published rated operational current is 515 A. The connection method must be designed correctly according to ABB’s installation requirements.

2. Adjustable Starting Performance

The soft starter allows engineers to configure starting parameters according to the connected motor and mechanical load.

Adjustable settings help achieve a controlled acceleration profile rather than applying full motor voltage immediately.

3. Reduced Mechanical Stress

Gradual motor acceleration can reduce sudden torque changes during startup. This helps protect mechanical components such as couplings, belts, gearboxes, and driven equipment.

4. Integrated Electronic Overload Protection

The PST300-600-70 includes electronic motor overload protection. Its adjustable rated motor current range is 30–115% of the selected rated current setting.

Correct configuration is necessary to ensure that protection settings correspond to the actual motor and application.

5. Wide Main Circuit Voltage Range

The device supports a main circuit operational voltage range of 208–600 V AC, providing flexibility for compatible industrial electrical systems.

The supply voltage must remain within the specified operating range and match the motor-control installation.

6. Flexible Connection Methods

The PST300-600-70 supports both in-line and inside-delta connection arrangements.

These arrangements have different current ratings and wiring requirements. Engineers must select the correct connection method and follow the manufacturer’s wiring diagrams.

7. Industrial Control Integration

The unit provides control connections and relay-based status functions for integration into suitable industrial control panels.

It can work alongside PLCs, motor protection equipment, contactors, and other control components as part of a coordinated motor-control system.

8. Adjustable Starting and Stopping Ramps

Configurable ramp times allow the motor’s acceleration and deceleration behavior to be adapted to the mechanical system.

This is particularly useful for applications where abrupt starting or stopping could affect product handling, equipment stability, or process continuity.

Technical FAQs

1. What is the ABB PST300-600-70?

The ABB PST300-600-70 is an industrial soft starter designed to control the starting and stopping of three-phase AC motors. It belongs to ABB’s PST advanced softstarter family and has a rated operational current of 300 A for in-line connection.

2. What is the rated current of this soft starter?

Its rated operational current is 300 A for in-line connection. For inside-delta connection, the published rated operational current is 515 A. The correct rating depends on the selected connection arrangement and application conditions.

3. What is the main voltage range?

The PST300-600-70 supports a main circuit operational voltage range of 208–600 V AC. It is designed for three-phase motor applications.

4. What control supply voltage does it require?

The rated control supply voltage is 100–250 V AC at 50/60 Hz. The control circuit also supports 24 V DC operation. The actual control wiring must follow the product documentation.

5. What is its motor power rating at 400 V?

For in-line connection, the published motor power rating at 400 V is 160 kW. For inside-delta connection, the corresponding published rating is 257 kW. Motor selection must also consider current, starting duty, and application conditions.

6. Does the PST300-600-70 have built-in overload protection?

Yes. It includes electronic motor overload protection. The adjustable rated motor current setting ranges from 30% to 115%, allowing the protection parameters to be configured for the connected motor.

7. What is the maximum starting capacity?

The published starting capacity at maximum rated current is 3 × Ie for 15 seconds. The actual permissible starting duty must also account for ambient temperature, motor load, starting frequency, and the soft starter’s thermal limits.

8. Can this soft starter be used with a PLC?

Yes. It can be integrated into an appropriately designed PLC-based motor-control system. The PLC can coordinate start and stop commands and monitor available status signals through the configured control interface.

9. What is the difference between in-line and inside-delta connection?

In-line connection places the soft starter in series with the motor supply conductors. Inside-delta connection places it within the motor’s delta winding circuit and requires a compatible six-lead motor arrangement. The current ratings and wiring requirements differ, so the correct configuration must be selected from ABB’s documentation.

10. What should be checked before replacing an existing PST300-600-70?

Verify the complete model number, rated current, supply voltage, control supply, connection method, control wiring, dimensions, and motor protection settings. Also inspect the condition of the terminals and connected equipment. A replacement should be commissioned according to the manufacturer’s instructions.

Introduction

The ABB PST300-600-70 1SFA894014R7000 Soft Starter is a high-current motor starting and stopping controller designed for industrial three-phase AC motor applications.

Manufactured by ABB, the PST series is intended for installations where controlling motor acceleration and deceleration is important for electrical and mechanical performance. Instead of applying full voltage to the motor immediately, the soft starter manages the voltage supplied during startup, helping reduce the effects of high starting current and sudden torque changes.

The PST300-600-70 supports main circuit voltages from 208 to 600 V AC and provides a rated operational current of 300 A when connected in-line. Its inside-delta connection rating is 515 A, offering an alternative installation arrangement for compatible motors.

The unit is designed for substantial industrial motor loads. At 400 V, its published motor power rating is 160 kW for in-line connection and 257 kW for inside-delta connection. These figures are reference ratings; actual motor suitability depends on operating conditions, load characteristics, starting duty, and the selected connection method.

The PST300-600-70 includes electronic overload protection and adjustable motor current settings. Its control supply operates within a 100–250 V AC range, with 24 V DC control circuit operation also specified.

With its high current capacity, adjustable starting parameters, and industrial control interfaces, the PST300-600-70 is suitable for appropriately engineered pump, fan, compressor, conveyor, and process-equipment installations.

Technical Specifications

Parameter Specification
Brand ABB
Manufacturer ABB
Model PST300-600-70
Product ID 1SFA894014R7000
Product Type Soft Starter
Product Series PST Advanced Range
Main Circuit Voltage 208–600 V AC
Rated Operational Current – In-Line 300 A
Rated Operational Current – Inside Delta 515 A
Motor Power at 400 V – In-Line 160 kW
Motor Power at 500 V – In-Line 200 kW
Motor Power at 400 V – Inside Delta 257 kW
Motor Power at 500 V – Inside Delta 355 kW
Control Supply Voltage 100–250 V AC
Control Circuit Voltage 24 V DC operation
Rated Frequency 50/60 Hz
Adjustable Rated Motor Current 30–115%
Starting Capacity 3 × Ie for 15 seconds
Service Factor 115%
Overload Protection Integrated electronic overload protection
Starting Ramp Time 1–30 seconds
Connection Methods In-Line / Inside Delta
Main Terminal Type Busbars
Dimensions 420 × 270 × 360 mm
Weight 23 kg
Main Terminal Protection IP00
Operating Temperature 0 to +50°C
Storage Temperature -25 to +70°C

Specifications are based on the PST300-600-70 product configuration. Confirm the applicable technical documentation before final installation or replacement.

Working Principle

The PST300-600-70 controls the voltage applied to a three-phase motor during startup and stopping. Its semiconductor switching technology regulates the motor’s voltage profile, allowing the motor to accelerate more gradually than it would under direct-on-line starting.

Controlled Motor Starting

When a start command is received, the soft starter begins applying voltage according to the configured starting parameters.

The voltage increases progressively, allowing the motor to accelerate while helping limit the initial electrical and mechanical impact.

The starting ramp and current settings should be adjusted according to the motor’s rated current, load torque, and required acceleration time.

Controlled Motor Stopping

When a stop command is received, the soft starter can control the motor’s stopping process according to the configured stopping parameters.

A controlled stop can be useful in applications where sudden stopping may cause pressure fluctuations, material movement, or mechanical shock.

The appropriate stopping method depends on the driven equipment and the process requirements.

Electronic Overload Protection

The integrated electronic overload function monitors motor operating conditions according to the configured protection settings.

The rated motor current must be entered correctly. Incorrect settings can lead to nuisance trips or insufficient motor protection.

The soft starter should be used together with the appropriate upstream short-circuit protection and installation-specific safety equipment.

System Integration

The PST300-600-70 can be incorporated into industrial motor-control panels alongside PLCs, contactors, protective devices, and operator interfaces.

PLC Control

A PLC can manage the motor’s start and stop sequence and coordinate the soft starter with other machinery. Available status and relay signals can be incorporated into the control logic according to the selected wiring arrangement.

Motor Protection

The integrated electronic overload function provides motor overload protection. Additional short-circuit protection and isolation equipment must be selected according to ABB’s recommendations and applicable electrical regulations.

Control Panel Installation

The unit is designed for installation inside a suitable electrical cabinet. Its main terminals are IP00, so the installation must provide the required protection against accidental contact and environmental exposure.

The cabinet should provide sufficient ventilation and clearance to manage heat generated during operation.

Commissioning

Before operation, verify the power supply, motor connections, control wiring, grounding, and selected connection method. Configure the motor current and starting parameters according to the motor nameplate and application requirements.

Maintenance and Replacement Considerations

The PST300-600-70 is a high-current industrial soft starter, so regular inspection and correct configuration are important for reliable service.

Maintenance personnel should inspect the main terminals, control connections, cabinet ventilation, and signs of overheating or contamination. Any abnormal noise, repeated overload trips, or unexpected starting behavior should be investigated before the equipment is returned to normal operation.

When replacing an existing unit, verify the complete product number 1SFA894014R7000. Confirm the rated current, voltage range, control supply, connection arrangement, and mounting dimensions.

A replacement with a similar current rating is not necessarily a direct substitute. Differences in wiring, control interfaces, protection settings, and starting characteristics may require engineering review and recommissioning.

Conclusion

The ABB PST300-600-70 1SFA894014R7000 Soft Starter is designed for high-current industrial motor applications requiring controlled starting and stopping. With a 300 A in-line rating, 515 A inside-delta rating, 208–600 V AC main circuit range, and integrated electronic overload protection, it provides a configurable solution for suitable industrial motor-control systems.

Its adjustable starting parameters and industrial integration capabilities make it relevant to pump stations, ventilation equipment, compressors, conveyors, and other motor-driven machinery.

For maintenance and replacement projects, verifying the complete model number, motor ratings, connection method, and control requirements is essential to ensure reliable system operation.



Related Products