Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric MT16N2 Circuit Breaker is a high-capacity air circuit breaker associated with the Masterpact NT family. Designed for low-voltage power distribution systems, this type of circuit breaker provides switching and protection functions for electrical installations in industrial plants, commercial buildings, and large power distribution networks.
Air circuit breakers are commonly installed in main distribution boards and high-capacity switchgear. They help protect electrical systems against abnormal current conditions, including overloads and short circuits. When a fault occurs and the configured protection system detects that operating conditions have exceeded its limits, the circuit breaker interrupts the current to help protect connected equipment and distribution infrastructure.
The MT16N2 is associated with the 1600 A current class. Its application is therefore different from that of small miniature circuit breakers or ordinary branch-circuit protective devices. It is intended for larger distribution circuits where high current capacity, coordinated protection, and reliable switching are important.
The Masterpact NT platform is designed for industrial and commercial power distribution applications. Depending on the selected configuration, the circuit breaker may be installed as a fixed or withdrawable device and may use different protection trip units and accessories.
The exact configuration should be confirmed from the nameplate and complete product documentation before installation or replacement. Pole count, mounting arrangement, trip-unit type, auxiliary contacts, and electrical ratings all influence compatibility.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Product Series | Masterpact NT |
| Model | MT16N2 |
| Product Type | Air Circuit Breaker (ACB) |
| Rated Current Class | 1600 A |
| Application | Low-voltage power distribution and circuit protection |
| Circuit Configuration | Confirm exact pole configuration from nameplate |
| Mounting Configuration | Supplied dimensions correspond to fixed three-pole reference configuration |
| Protection | Overload and short-circuit protection, subject to installed trip unit |
| Operating Frequency | Verify according to the exact product configuration |
| Dimensions Provided | 301 × 196 × 276 mm |
| Weight Provided | 14 kg |
| Typical Installation | Main distribution boards and industrial switchgear |
Important: The dimensions and weight supplied correspond closely to the fixed three-pole Masterpact NT06–NT16 reference data. Confirm the exact MT16N2 nameplate, pole count, mounting arrangement, and trip-unit details before ordering or replacing the breaker. Do not assume that all MT16N2 configurations share identical specifications.
The MT16N2 is designed to perform switching and protective functions in a low-voltage electrical distribution system. Its operation involves current monitoring, fault detection through the installed protection arrangement, and mechanical interruption of the electrical circuit.
An overload occurs when a circuit carries more current than its intended operating capacity for a sustained period.
The installed protection unit monitors the circuit and responds when the current exceeds the configured overload threshold for the specified time. The breaker then opens its contacts to interrupt the circuit.
This function helps protect cables, busbars, transformers, and connected equipment from excessive heating caused by prolonged overcurrent conditions.
A short circuit can produce a very high fault current within a short period. Such conditions may cause serious thermal and mechanical stress on electrical equipment.
The circuit breaker’s protection system detects fault conditions and initiates interruption according to its protection settings and rated breaking capability.
The exact short-circuit performance depends on the breaker variant and its documented electrical ratings. Engineers should verify the applicable Icu and Ics values at the intended operating voltage before selecting the device.
Air circuit breakers are used to connect and disconnect electrical circuits during normal operation and maintenance activities.
Depending on the installed arrangement, the MT16N2 may serve as an incoming, outgoing, or bus-coupler breaker within a distribution system.
Where isolation is required, the installation must follow the manufacturer’s instructions and applicable electrical safety procedures. A circuit breaker should not automatically be treated as a substitute for every required isolation or lockout device.
When a circuit breaker opens under load or fault conditions, an electrical arc can form between its separating contacts.
An air circuit breaker uses an arc-control arrangement to manage and extinguish the arc. This allows the device to interrupt current safely within its specified operating limits.
The arc-interruption capability is an important consideration when selecting a breaker for a high-current distribution system.
The breaker is normally part of a coordinated electrical protection system. Its protection settings should be selected in relation to upstream and downstream protective devices.
Proper coordination helps ensure that the protective device closest to a fault operates where possible, limiting unnecessary interruption to other parts of the installation.
The MT16N2 can serve as a major switching and protection component in an industrial low-voltage distribution network.
In a main distribution board, a high-capacity air circuit breaker may be installed at the incoming supply point. It provides a means of switching the main circuit and protecting downstream distribution equipment.
The 1600 A current class makes the MT16N2 relevant to installations with substantial electrical loads, subject to the actual system design and breaker ratings.
The breaker may also be used in an outgoing feeder position to protect a major distribution branch.
A feeder can supply production equipment, motor control centers, transformers, or secondary distribution panels. The protective settings must be coordinated with the feeder cable capacity and downstream equipment.
Large industrial switchboards use busbars to distribute electrical power between incoming supplies and outgoing circuits.
A suitably configured air circuit breaker can serve as part of this distribution arrangement. Its rated current, short-circuit capacity, and connection configuration must match the switchboard design.
Air circuit breakers are also important during maintenance and equipment replacement activities. Their switching arrangements can help authorized personnel isolate sections of a distribution system according to the approved operating procedure.
Before maintenance, the circuit must be de-energized and verified safe. Personnel should follow the applicable lockout/tagout and electrical safety requirements.
Large manufacturing facilities often require substantial electrical distribution capacity for production lines, machine tools, material-handling equipment, and auxiliary systems.
A 1600 A class air circuit breaker may be used in the main or feeder distribution system where its electrical ratings match the installation.
Industrial power distribution rooms contain switchboards that distribute electricity to different plant areas.
The MT16N2 can be considered for compatible switchgear applications where high-current switching and protective functions are required.
Large commercial facilities may have substantial electrical loads from HVAC equipment, elevators, lighting systems, and other building services.
High-capacity air circuit breakers can be used in main distribution equipment to protect major electrical circuits.
Water treatment plants, transportation facilities, and other infrastructure installations often depend on reliable electrical distribution.
A properly selected air circuit breaker helps protect distribution circuits and supports planned switching and maintenance operations.
Utility areas within industrial facilities may contain pumps, compressors, cooling equipment, and auxiliary power systems.
The breaker can be used in an appropriate distribution arrangement to protect a major supply circuit, provided that the short-circuit and current ratings meet the system requirements.
Correct installation is essential for safe operation and dependable electrical protection.
Before installation, confirm the rated current, operational voltage, frequency, pole count, and short-circuit breaking capacity.
The 1600 A current class alone is not enough to determine suitability. The available fault current at the installation point must be compared with the circuit breaker’s documented breaking capacity.
The supplied dimensions are 301 × 196 × 276 mm, with a listed weight of 14 kg.
These values are consistent with the fixed three-pole reference configuration in the Masterpact NT06–NT16 installation data. A four-pole or withdrawable version may have different dimensions and weight.
Check the mounting arrangement, connection positions, clearances, and switchboard design before installation.
The protection trip unit determines how the breaker responds to abnormal electrical conditions.
Before commissioning, verify the installed trip unit and its available protection functions. Configure long-time, short-time, instantaneous, and other available settings according to the system protection study and manufacturer’s instructions.
Do not use generic settings without considering cable ratings, load characteristics, fault levels, and coordination requirements.
Inspect the busbar connections, terminals, contact surfaces, and fastening hardware before energizing the breaker.
Loose or incorrectly installed connections can create excessive resistance and localized heating. Connection torque must follow the manufacturer’s installation requirements.
Depending on the configuration, the breaker may be equipped with auxiliary contacts, shunt trip devices, undervoltage releases, motor mechanisms, or other accessories.
Confirm that the auxiliary circuits match the control voltage and wiring design of the switchboard.
Before returning the breaker to service, carry out the required mechanical and electrical checks.
These may include:
Testing should be performed by qualified personnel using approved procedures and suitable equipment.
The MT16N2 is normally installed as part of a larger low-voltage switchgear assembly.
| Component | Function | Integration Considerations |
|---|---|---|
| Low-voltage switchboard | Houses and distributes electrical circuits | Verify breaker mounting and connection dimensions |
| Copper busbars | Carry current between distribution components | Confirm current capacity, spacing, and connection arrangement |
| Protection trip unit | Detects abnormal current conditions | Verify exact trip-unit model and protection settings |
| Auxiliary contacts | Provide breaker status signals | Check contact ratings and control-circuit wiring |
| Shunt trip device | Enables remote tripping | Confirm control voltage and wiring requirements |
| Undervoltage release | Trips or prevents closing under specified voltage conditions | Verify the selected accessory and control supply |
| Operating mechanism | Supports breaker opening and closing | Confirm mechanical compatibility |
| Upstream protection | Provides coordinated protection for the supply | Perform protection coordination calculations |
| Downstream breakers | Protect individual feeders and loads | Coordinate time-current characteristics |
| Electrical monitoring system | Monitors distribution conditions | Verify the available measurement and communication accessories |
The components listed are possible elements of a complete switchgear installation. They are not necessarily included with the MT16N2 breaker.
When replacing an MT16N2, the replacement should be selected according to the complete electrical and mechanical configuration.
| Alternative or Related Product | Replacement Considerations |
|---|---|
| Another Masterpact NT16 variant | Check rated current, breaking capacity, pole count, mounting style, and trip unit |
| Masterpact NT12 | Lower current class; not a direct substitute without system review |
| Masterpact NT20 | Higher current class; requires verification of switchboard and protection compatibility |
| Masterpact MTZ2 16 | Newer Masterpact family option for certain applications; requires engineering review |
| Other Schneider Electric air circuit breakers | Compare electrical ratings, dimensions, accessories, and switchboard compatibility |
Before selecting a replacement, verify:
A breaker with the same current rating is not automatically a suitable replacement. Differences in breaking capacity, protection functions, mechanical mounting, and accessories can affect the safety and operation of the distribution system.
The MT16N2 belongs to the 1600 A current class, making it relevant to major low-voltage distribution circuits where substantial current capacity is required.
When equipped with the appropriate protection unit, the breaker can provide overload and short-circuit protection for compatible electrical circuits.
Its air circuit breaker design allows it to be considered for incoming, outgoing, and other major distribution positions in suitable switchgear assemblies.
The Masterpact NT family is designed for use in industrial and commercial low-voltage distribution equipment.
The available protection and accessory configuration can vary according to the selected breaker version, allowing engineers to specify equipment according to system requirements.
Accurate identification of the model and configuration helps maintenance teams source suitable replacement equipment for existing distribution systems.
The MT16N2 is a Masterpact NT family air circuit breaker associated with the 1600 A current class. It is designed for switching and protection in low-voltage power distribution systems.
The model designation is associated with a 1600 A current class. Confirm the actual nameplate and technical documentation before using this value for system design.
An air circuit breaker provides switching and protective functions in electrical distribution systems. It can interrupt current under specified abnormal conditions, including overloads and short circuits, when equipped with the appropriate protection arrangement.
It may be suitable for compatible industrial switchboards designed for its electrical and mechanical ratings. The rated voltage, breaking capacity, pole count, mounting arrangement, and connection dimensions must all be checked.
A fixed circuit breaker is mounted directly in its designated switchgear position. A withdrawable breaker is installed in a compatible cradle and can be moved between defined positions for isolation and maintenance procedures.
The two arrangements have different mechanical interfaces and dimensions.
The protection functions depend on the installed trip unit and its configuration. Verify the exact protection unit and settings before commissioning.
Check the complete model designation, rated current, voltage, breaking capacity, pole count, trip unit, mounting arrangement, busbar connections, and installed accessories.
The supplied listing values are 301 × 196 × 276 mm and 14 kg. These correspond closely to the fixed three-pole reference configuration for the Masterpact NT06–NT16 range. Confirm the exact configuration before shipment or installation.
A Masterpact MTZ2 may be considered as part of an upgrade, but it should not be assumed to be a direct mechanical or electrical replacement. Switchboard compatibility, protection settings, accessories, and commissioning requirements must be reviewed.
Maintenance may include inspection of the operating mechanism, electrical connections, contact condition, insulation, trip unit, and auxiliary circuits. The maintenance interval and test procedures should follow the manufacturer’s instructions and the site’s electrical maintenance program.
When purchasing a Schneider Electric MT16N2 circuit breaker, verify the complete product designation and configuration rather than relying on the model family alone.
For replacement projects, request clear photographs of the nameplate, front panel, terminals, and mounting arrangement. Confirm the pole count, trip-unit type, accessory configuration, rated current, and electrical performance.
For used or refurbished breakers, check the mechanical operating condition, contact system, insulation condition, auxiliary components, and available test records. For critical power distribution equipment, appropriate inspection and testing should be completed before installation.
During maintenance, follow the manufacturer’s procedures and applicable electrical safety requirements. Keep the switchgear clean, inspect connections for signs of overheating, and verify that the operating and protection mechanisms function correctly.
The breaker should only be installed, configured, and maintained by qualified personnel. Protection settings must be based on the actual electrical system design rather than copied from another installation.
The Schneider Electric MT16N2 Masterpact NT Circuit Breaker is a high-capacity air circuit breaker associated with the 1600 A class. It is intended for low-voltage power distribution applications that require reliable switching and protection of major electrical circuits.
With supplied dimensions of 301 × 196 × 276 mm and a weight of 14 kg, the listed configuration corresponds closely to the fixed three-pole reference dimensions for the Masterpact NT06–NT16 range. Exact pole count, mounting arrangement, trip-unit configuration, and breaking capacity should be confirmed before procurement.
For industrial maintenance, switchgear replacement, and power distribution projects, accurate product identification and electrical compatibility checks are essential for safe and dependable operation.