• Schneider MT16NA Circuit Breaker
  • Schneider MT16NA Circuit Breaker
  • Schneider MT16NA Circuit Breaker
  • Schneider MT16NA Circuit Breaker
Product Overview The Schneider Electric MT16NA Circuit Breaker is an industrial low-voltage air circuit breaker associated with the Masterpact MT series. Designed for power distribution and electrical p……
Schneider MT16NA Circuit Breaker
  • Schneider
  • MT16NA
  • Circuit Breaker
  • France
  • 301 x 196 x 276 mm
  • 14 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Schneider MT16NA Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT16NA Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT16NA Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT16NA Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MT16NA Circuit Breaker is an industrial low-voltage air circuit breaker associated with the Masterpact MT series. Designed for power distribution and electrical protection applications, this type of circuit breaker is used to protect electrical installations against abnormal current conditions and to provide switching and isolation functions in industrial power systems.

Air circuit breakers are commonly installed in main distribution panels, switchgear assemblies, industrial substations, and large electrical control systems. They are designed for applications where higher current ratings and configurable protection functions are required.

The MT16NA belongs to the MT16 frame category, associated with a 1600 A current rating. It can be considered for applications involving main power distribution, feeder protection, and power system sectionalization. The exact protection and switching characteristics depend on the complete breaker configuration, including its trip unit, pole arrangement, installation type, and rated breaking capacity.

In an industrial electrical distribution system, the circuit breaker serves as an important protective component. It monitors the electrical circuit through its protection mechanism and interrupts current when a qualifying fault or abnormal condition is detected. This helps reduce the risk of damage to cables, transformers, motors, busbars, and other connected equipment.

The MT16NA is relevant to maintenance and replacement projects involving legacy Schneider Electric Masterpact equipment. When sourcing this model, engineers should verify the complete identification information on the breaker nameplate because similar-looking Masterpact units may have different electrical and mechanical configurations.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series Masterpact MT
Model MT16NA
Product Type Air Circuit Breaker
Product Category Low-Voltage Power Circuit Breaker
Frame Category MT16
Current Rating 1600 A frame category
Operating Principle Air circuit interruption
Application Industrial power distribution and circuit protection
Typical Installation Main switchboards and low-voltage switchgear
Protection Function Depends on installed trip unit
Pole Configuration Verify from nameplate
Mounting Configuration Verify fixed or drawout version
Rated Operational Voltage Verify from nameplate
Rated Breaking Capacity Verify from exact configuration
Trip Unit Verify installed model
Dimensions Provided 301 × 196 × 276 mm
Weight Provided 14 kg

Important: The table distinguishes the MT16 frame category from the exact electrical ratings of an individual breaker. The complete nameplate and configuration are required to establish the rated voltage, breaking capacity, pole arrangement, and protection characteristics.

Function and Working Principle

The Schneider Electric MT16NA circuit breaker is designed to provide switching and protective functions in industrial electrical distribution systems. Its operation involves monitoring circuit conditions, responding to abnormal current, and interrupting the electrical path when the protection mechanism determines that disconnection is necessary.

1. Overcurrent Protection

Overcurrent occurs when the current flowing through an electrical circuit exceeds the permitted operating level. It may result from an overloaded circuit, equipment malfunction, or an abnormal operating condition.

A circuit breaker’s protection system detects qualifying overcurrent conditions and initiates a trip when the configured protection threshold and time delay are reached.

The actual protection settings depend on the installed trip unit and its configuration. Correct coordination with downstream and upstream protective devices is essential to avoid unnecessary interruptions.

2. Short-Circuit Protection

A short circuit can produce a very high current within a short period. If the fault is not interrupted promptly, it may cause severe thermal and mechanical stress to electrical equipment.

Air circuit breakers are designed to interrupt fault currents within their specified breaking capacity. When a qualifying short-circuit condition is detected, the trip mechanism releases the operating mechanism and the contacts separate.

The resulting electrical arc must be controlled and extinguished by the breaker’s arc-interruption system. The allowable fault current depends on the exact rated breaking capacity of the installed configuration.

3. Switching and Isolation

Besides protection, an air circuit breaker can be used for controlled switching of electrical circuits. This allows operators and maintenance personnel to disconnect sections of a distribution system when required.

Depending on the installation, the breaker may be used as a main incoming device, feeder breaker, or bus-section breaker.

Isolation procedures must follow the applicable electrical safety requirements. Opening a circuit breaker should not automatically be treated as proof that all parts of an electrical installation are safe to work on.

4. Protection Coordination

In a multi-level power distribution system, protective devices should be coordinated so that a fault is cleared by the device closest to the fault whenever possible.

The trip settings of the MT16NA and associated downstream breakers must be evaluated together. Proper coordination can help limit unnecessary outages and maintain power to unaffected sections of the facility.

Role in Industrial Power Distribution Systems

The MT16NA can serve as a major switching and protection device within an industrial low-voltage distribution system.

Main Incoming Protection

In a main distribution panel, a high-current air circuit breaker may be installed at the incoming power section. Its role is to provide a controlled means of disconnecting the incoming supply and protecting the downstream distribution system.

The required protection settings depend on the transformer capacity, available fault current, cable ratings, and the overall distribution design.

Feeder Circuit Protection

Industrial facilities often contain multiple outgoing feeders supplying motors, production lines, auxiliary systems, and sub-distribution panels.

An appropriately configured air circuit breaker can protect an individual feeder and provide a switching point for maintenance or system reconfiguration.

Busbar Sectionalization

Large distribution systems may be divided into separate busbar sections. A circuit breaker can be used as part of the switching arrangement that connects or separates these sections.

This arrangement supports maintenance planning and power distribution flexibility. The actual switching arrangement depends on the switchgear design.

Electrical System Maintenance

For legacy installations, maintaining the original breaker configuration can be important. Replacing an existing breaker with an incorrectly configured alternative may affect mechanical mounting, electrical connections, protection coordination, and operating procedures.

Accurate model identification is therefore essential when sourcing replacement equipment.

Industrial Applications

1. Manufacturing Plants

Manufacturing facilities rely on electrical distribution systems to supply production machinery, motor control centers, lighting, and auxiliary equipment.

An appropriately configured Masterpact MT circuit breaker can be used in main distribution or feeder applications where high-current switching and protection are required.

2. Industrial Switchgear

Low-voltage switchgear assemblies contain protective devices that distribute power to different sections of a facility.

The MT16NA may be encountered in legacy switchgear installations where an MT16-class breaker is required for maintenance or replacement.

3. Power Distribution Panels

Large electrical panels often require circuit breakers with higher current ratings to protect incoming supplies and distribution feeders.

Air circuit breakers provide switching and protection functions in these installations, subject to the electrical ratings of the selected configuration.

4. Industrial Utilities

Water treatment plants, utility facilities, and other infrastructure installations depend on reliable power distribution.

Circuit breakers are used to protect electrical feeders supplying pumps, ventilation systems, control equipment, and other essential loads.

5. Commercial and Infrastructure Facilities

Large buildings and infrastructure facilities may use low-voltage air circuit breakers in their main electrical distribution systems.

The selection of a suitable breaker must account for the installation voltage, load current, short-circuit level, and required protection functions.

Installation and System Integration

Correct installation is essential for safe and reliable operation. Air circuit breakers are high-energy electrical devices and should be installed, tested, and maintained by qualified electrical personnel.

1. Verify the Complete Model Configuration

Before installation, confirm the exact model and nameplate information. The MT16 frame designation alone does not establish every electrical characteristic.

Check the following information:

  • Rated operational voltage.
  • Rated current and frame rating.
  • Number of poles.
  • Rated ultimate breaking capacity.
  • Rated service breaking capacity.
  • Fixed or drawout construction.
  • Installed trip unit and protection settings.
  • Terminal and connection arrangement.

These details must match the requirements of the switchgear and the electrical distribution system.

2. Check Mechanical Dimensions

The supplied dimensions are 301 × 196 × 276 mm, with a listed weight of 14 kg.

Before replacing an existing breaker, compare the physical dimensions, mounting points, connection positions, and required operating clearances with the installed switchgear.

Do not assume that breakers in the same current frame category have identical mechanical interfaces.

3. Verify Electrical Connections

Check the incoming and outgoing terminal arrangements, conductor sizes, busbar connections, and specified tightening requirements.

Connections should be inspected for signs of overheating, corrosion, or mechanical damage. Electrical connections must be installed according to the manufacturer’s instructions and applicable electrical codes.

4. Configure the Protection System

The protection settings must be selected according to the installation’s load characteristics and fault-current calculations.

Protection coordination should consider transformer characteristics, cable ampacity, downstream protective devices, and the available short-circuit current.

Do not copy protection settings from another breaker without confirming that the equipment and electrical system are equivalent.

5. Perform Commissioning Tests

Before energizing the installation, qualified personnel should verify the mechanical and electrical condition of the breaker.

Depending on the installation and applicable procedures, commissioning may include:

  • Visual inspection.
  • Mechanical operation checks.
  • Electrical connection inspection.
  • Trip-unit configuration verification.
  • Protection testing.
  • Insulation and continuity checks where applicable.
  • Verification of auxiliary contacts and control circuits.
  • Confirmation of interlocking and operating arrangements.

The breaker should only be returned to service after the required inspection and testing procedures have been completed.

Compatible System Components

The MT16NA is used as part of a wider electrical distribution system. The following components may be found in installations using this type of air circuit breaker.

Component Function Integration Considerations
Low-voltage switchgear Houses and distributes electrical power Verify breaker dimensions and mechanical compatibility
Main busbar system Distributes power between circuit sections Confirm current capacity and connection arrangement
Protection trip unit Detects abnormal electrical conditions Verify exact model and protection functions
Current transformers Provide current measurement signals Confirm ratio, accuracy, and protection requirements
Auxiliary contacts Provide breaker status signals Verify contact configuration and control voltage
Shunt trip accessory Enables remote electrical tripping Confirm accessory compatibility and coil voltage
Undervoltage release Initiates tripping under specified voltage conditions Verify rated control voltage and installed option
Electrical control panel Provides control and monitoring functions Confirm wiring and interface requirements
Downstream circuit breakers Protect outgoing circuits Coordinate trip settings and breaking capacities
Power monitoring equipment Measures electrical operating conditions Confirm measurement and communication requirements

The actual accessories supplied with the breaker depend on its configuration. Do not assume that optional trip units, auxiliary contacts, or electrical releases are included with every MT16NA unit.

Alternative Models and Replacement Considerations

When replacing an MT16NA, the alternative must be evaluated against the original breaker’s electrical, mechanical, and protection characteristics.

Alternative or Related Product Consideration
Schneider Electric Masterpact MT16 variant May be relevant for legacy replacement, but the complete configuration must match
Schneider Electric Masterpact MTZ1 A newer product family that may be considered for an engineered upgrade
Schneider Electric Masterpact MTZ2 Suitable for certain higher-current distribution applications, subject to system design
Schneider Electric Masterpact NT Another low-voltage air circuit breaker family; verify frame and electrical compatibility
Other 1600 A air circuit breakers Must be evaluated for voltage, breaking capacity, mounting, protection, and connection requirements

A replacement decision should consider:

  1. Rated operational voltage.
  2. Continuous current rating.
  3. Rated short-circuit breaking capacity.
  4. Number of poles.
  5. Fixed or drawout construction.
  6. Mechanical dimensions and connection layout.
  7. Protection trip unit and available functions.
  8. Auxiliary contacts and electrical accessories.
  9. Switchgear compatibility.
  10. Applicable electrical standards and coordination requirements.

A breaker with the same 1600 A current rating is not automatically a suitable replacement. The complete protection and mechanical configuration must be reviewed.

Key Advantages

High-Current Distribution Capability

The MT16 frame category is associated with a 1600 A current rating, making it relevant to industrial distribution systems requiring higher-current switching and protection equipment.

Circuit Protection

An appropriately configured air circuit breaker can protect electrical distribution circuits against qualifying overload and short-circuit conditions.

Switching Functionality

The breaker can provide a controlled switching point within a low-voltage distribution system, supporting maintenance and operational requirements.

Industrial Switchgear Application

Masterpact MT equipment is associated with industrial and commercial power distribution applications, including main switchboards and feeder systems.

Maintenance and Replacement Relevance

The MT16NA is relevant to legacy equipment maintenance, where accurate identification and configuration matching are important for restoring existing electrical installations.

Technical FAQs

1. What is the Schneider Electric MT16NA?

The Schneider Electric MT16NA is an air circuit breaker associated with the Masterpact MT series. It is used in low-voltage electrical distribution systems for switching and circuit protection.

2. What does MT16 represent?

MT16 identifies the 1600 A frame category within the Masterpact MT series. The actual rated current and protection configuration should be confirmed from the breaker nameplate.

3. What is the rated current of the MT16NA?

The MT16 frame category is associated with a 1600 A current rating. Confirm the exact rating of the individual breaker before using it in an electrical design.

4. What is the difference between an air circuit breaker and a molded case circuit breaker?

An air circuit breaker is generally used in higher-current low-voltage distribution systems and often provides configurable protection and switching functions. A molded case circuit breaker uses a molded insulating housing and is commonly used in feeder and branch protection applications.

The appropriate device depends on the system voltage, current, available fault current, and installation requirements.

5. Can the MT16NA be used as a main circuit breaker?

An appropriately rated and configured MT16 breaker may be used in a main distribution application. The suitability of a particular unit depends on its voltage rating, breaking capacity, trip unit, installation type, and the electrical system design.

6. Does the MT16NA include an electronic trip unit?

The installed trip unit must be verified from the actual breaker configuration. The MT16NA designation alone does not establish the exact trip-unit model or protection functions.

7. Can it replace another 1600 A circuit breaker?

Not automatically. Mechanical dimensions, terminal arrangements, pole configuration, breaking capacity, trip characteristics, and accessory requirements must all be checked before substitution.

8. What should be checked before purchasing a used MT16NA?

Inspect the nameplate, mechanical condition, operating mechanism, terminals, arc-control components, trip unit, and available test records. Confirm the exact configuration and whether the unit has been functionally tested.

9. What are the dimensions and weight of this product?

The supplied listing information gives dimensions of 301 × 196 × 276 mm and a weight of 14 kg. Verify the actual unit and shipping packaging before transportation planning.

10. Why is the exact breaker configuration important?

Different configurations can have different electrical ratings, protection functions, mounting arrangements, and accessories. Selecting an incorrect configuration may cause installation problems or compromise the protection coordination of the electrical system.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric MT16NA, begin by confirming the complete model identification and inspecting the nameplate. The 1600 A frame category is useful for initial identification, but it is not sufficient to establish the complete electrical specification.

For replacement projects, compare the existing breaker’s voltage, current rating, breaking capacity, pole arrangement, trip unit, mechanical structure, and accessories. Confirm whether the equipment is fixed or drawout and whether the existing switchgear can accept the replacement.

For used or surplus circuit breakers, request clear photographs of the nameplate, terminals, operating mechanism, and trip unit. Ask for available inspection or test records and verify the condition of the equipment before purchase.

Routine maintenance should follow the manufacturer’s recommendations and applicable electrical safety procedures. Inspection may include contact condition, mechanical operation, connection integrity, auxiliary circuits, protection settings, and cleanliness.

Circuit breakers should be tested and serviced by qualified personnel. Any modification to protection settings or replacement of accessories should be documented to maintain the integrity of the electrical protection system.

Conclusion

The Schneider Electric MT16NA Circuit Breaker is a Masterpact MT series air circuit breaker associated with the 1600 A frame category. It is intended for industrial low-voltage power distribution applications requiring circuit protection and switching functionality.

Its use in main switchboards, feeder circuits, and industrial electrical distribution systems depends on the exact breaker configuration and the requirements of the installation. For maintenance and replacement projects, verifying the nameplate, rated breaking capacity, trip unit, pole arrangement, and mounting structure is essential.

With accurate identification and appropriate electrical engineering review, the MT16NA can be evaluated as a replacement component for compatible legacy Masterpact MT installations.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501