• Schneider NW12N2 Circuit Breaker
  • Schneider NW12N2 Circuit Breaker
  • Schneider NW12N2 Circuit Breaker
  • Schneider NW12N2 Circuit Breaker
Product Overview The Schneider NW12N2 Masterpact NW Circuit Breaker is an industrial low-voltage power protection device designed for use in large electrical distribution systems. It belongs to Schneide……
Schneider NW12N2 Circuit Breaker
  • Schneider
  • NW12N2
  • Circuit Breaker
  • France
  • 352 x 537 x 297 mm
  • 65 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider NW12N2 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW12N2 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW12N2 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW12N2 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider NW12N2 Masterpact NW Circuit Breaker is an industrial low-voltage power protection device designed for use in large electrical distribution systems. It belongs to Schneider Electric’s Masterpact NW family, a range of air circuit breakers developed for demanding power distribution applications in industrial facilities, commercial buildings, and critical infrastructure.

Circuit breakers play an essential role in electrical distribution networks. They protect electrical circuits and connected equipment by interrupting current when abnormal operating conditions, such as overloads or short circuits, occur. They can also provide a means of isolating electrical equipment for inspection and maintenance when installed in an appropriate configuration.

The Masterpact NW family includes different frame sizes, current ratings, interrupting capacities, trip-unit options, and mounting arrangements. The NW12 designation is associated with the 1200 A UL W-frame family, while related IEC versions use different catalog designations and ratings. The complete model designation and nameplate must therefore be checked before determining the exact electrical characteristics of an individual unit.

The NW12N2 is intended for integration into a properly engineered low-voltage distribution system. Its application may include main incoming protection, distribution feeder protection, and protection of large electrical loads. The actual function depends on the selected trip unit, sensor rating, pole configuration, and switchboard design.

For maintenance and replacement projects, accurate identification is especially important. Circuit breakers that share a similar frame designation may have different voltage ratings, short-circuit breaking capacities, connection arrangements, and control accessories.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family Masterpact NW
Model NW12N2
Product Type Air Circuit Breaker
Application Low-voltage power distribution and circuit protection
Frame Family NW12 / W-frame family
Frame Current Class 1200 A class for the UL NW12 family
Rated Operational Voltage Verify from the unit nameplate
Rated Current / Sensor Rating Verify exact trip-unit and sensor configuration
Number of Poles Verify from the complete breaker configuration
Breaking Capacity Depends on the exact N2 variant and applicable standard
Trip Unit Depends on the supplied configuration
Mounting Arrangement Verify fixed or drawout configuration
Dimensions Provided 352 × 537 × 297 mm
Weight Provided 65 kg
Typical Installation Industrial switchboards and low-voltage distribution assemblies

Important: NW12 family members are available in different configurations. Do not use the 1200 A frame designation as confirmation of the installed sensor rating or trip-unit setting. Confirm voltage, poles, interrupting capacity, trip-unit type, and mounting arrangement from the actual nameplate and technical documentation.

Function and Working Principle

The Masterpact NW12N2 is designed to protect electrical distribution circuits by detecting abnormal current conditions and opening its main contacts when the protection system determines that interruption is required.

1. Overload Protection

An overload occurs when a circuit carries more current than its permitted operating level for a sustained period. Prolonged overload conditions can cause conductors, terminals, and electrical equipment to overheat.

The circuit breaker’s protection system monitors current and can initiate a trip when the configured overload protection threshold and time characteristics are exceeded.

The exact long-time protection settings depend on the installed trip unit and its configuration. These settings must be coordinated with cable ampacity, equipment ratings, and the overall protection strategy.

2. Short-Circuit Protection

A short circuit can produce a very high current within a short period. Without suitable protection, this fault current can cause severe thermal and mechanical stress on electrical equipment.

The circuit breaker is designed to interrupt fault current within its specified breaking capacity. The appropriate breaker version must be selected according to the prospective short-circuit current at the installation point.

The N2 designation should not be used alone to determine the breaking capacity. The applicable voltage, standard, and complete model information must be confirmed.

3. Ground-Fault Protection

Depending on the installed protection unit and configuration, a Masterpact NW breaker may support ground-fault protection.

Ground-fault protection helps detect current flowing through unintended paths to ground. When correctly configured, this function can reduce the risk of equipment damage and support coordinated protection of the electrical distribution network.

Not every breaker configuration necessarily includes the same ground-fault protection functions. Verify the installed trip unit and settings before relying on this feature.

4. Circuit Isolation

A circuit breaker can provide a means of opening and isolating a protected electrical circuit. In a suitable switchboard arrangement, this allows maintenance personnel to isolate equipment before inspection or servicing.

Isolation procedures must follow the applicable electrical safety requirements. Opening the breaker alone should not be treated as proof that all hazardous energy has been removed.

5. Fault Indication and Monitoring

Depending on the installed trip unit and accessories, the breaker may provide trip indication, status contacts, and other monitoring functions.

These signals can be integrated into a supervisory control system or building management system. The actual available signals depend on the breaker configuration and installed auxiliary accessories.

Role in Industrial Power Distribution Systems

The NW12N2 can serve as a protection component in a low-voltage electrical distribution system. It is commonly considered for applications where large electrical loads and high distribution currents require coordinated circuit protection.

Main Incoming Protection

In a main switchboard, a suitably rated Masterpact NW circuit breaker can be installed as part of the incoming power protection arrangement.

It helps protect downstream distribution equipment from overload and short-circuit conditions. The selection must account for the supply characteristics, prospective fault current, and coordination with upstream protection.

Distribution Feeder Protection

Industrial switchboards often divide incoming power into multiple outgoing feeders. A circuit breaker can protect an individual feeder supplying a production line, distribution panel, or large electrical load.

Protection coordination is important so that a fault in one feeder does not unnecessarily interrupt the entire electrical installation.

Generator and Transformer Distribution

Large electrical distribution systems may use circuit breakers in generator and transformer applications. The breaker must be selected according to the electrical characteristics of the source, the expected fault current, and the protection requirements.

Generator and transformer protection requires detailed engineering. A circuit breaker should not be selected solely by comparing nominal current ratings.

Integration with Monitoring Systems

When suitable auxiliary contacts and monitoring accessories are installed, breaker status can be communicated to a PLC, power monitoring system, or supervisory control platform.

This allows operators to monitor breaker position, trip conditions, and selected electrical system events. Available monitoring functions depend on the installed accessories and communication architecture.

Industrial Applications

The Schneider Masterpact NW family is intended for demanding low-voltage distribution applications.

1. Industrial Manufacturing Facilities

Manufacturing plants use large electrical distribution systems to supply production machinery, motors, control panels, and auxiliary equipment.

A suitably configured NW12 circuit breaker can form part of the main or feeder protection arrangement, helping protect distribution circuits against abnormal current conditions.

2. Data Centers

Data centers require reliable power distribution for servers, cooling equipment, UPS systems, and supporting infrastructure.

Large air circuit breakers may be used in main distribution boards and other appropriately designed power distribution assemblies. Protection coordination and system redundancy are particularly important in these installations.

3. Commercial Buildings

Large commercial buildings often contain electrical switchboards supplying HVAC systems, elevators, lighting distribution, and other substantial electrical loads.

A suitable Masterpact NW configuration can provide protection and isolation within these distribution systems.

4. Power Generation Facilities

Power generation installations use circuit breakers to connect and protect distribution equipment, auxiliary systems, and selected power circuits.

The breaker configuration must be selected according to the source characteristics, fault levels, and required protection coordination.

5. Infrastructure and Utility Facilities

Water treatment plants, transportation facilities, and other infrastructure installations rely on dependable electrical distribution.

Masterpact NW breakers may be used in appropriately engineered switchboards to protect important distribution circuits and support maintenance isolation.

Installation and System Integration

Because the NW12N2 is a large power circuit breaker, installation requires appropriate switchboard engineering and qualified electrical personnel.

1. Verify the Complete Product Configuration

Before installation, confirm the complete model designation and the information shown on the breaker nameplate.

Important details include:

  • Rated operational voltage.
  • Rated current and sensor rating.
  • Number of poles.
  • Rated short-circuit breaking capacity.
  • Installed trip-unit type.
  • Fixed or drawout mounting arrangement.
  • Connection orientation.
  • Auxiliary contacts and accessories.

These details determine whether the breaker is suitable for the intended distribution system.

2. Check Switchboard Compatibility

The supplied dimensions are 352 × 537 × 297 mm, and the supplied weight is 65 kg.

Before designing or modifying a switchboard, confirm the actual dimensions, mounting points, connection arrangements, and required operating clearances using the manufacturer’s mechanical drawings.

The breaker is a heavy electrical component. Lifting equipment and suitable mechanical support may be required during installation.

3. Verify Electrical Ratings

The breaker must be suitable for the system’s operating voltage, current, and prospective short-circuit current.

Its interrupting capacity must be sufficient for the available fault current at the installation point. The protection settings must also be coordinated with upstream and downstream devices.

4. Inspect Main Connections

Inspect the main terminals, busbar connections, contact surfaces, and associated hardware before energizing the equipment.

Connections must be installed using the manufacturer’s specified procedures and tightening requirements. Poor connections can produce excessive resistance and localized heating.

5. Configure Protection Settings

The trip unit must be configured according to the electrical installation’s protection study.

Relevant settings may include long-time, short-time, instantaneous, and ground-fault protection, depending on the installed trip unit.

Incorrect settings can result in nuisance tripping or inadequate protection. Settings should be reviewed by qualified electrical engineers.

6. Test Before Energization

Before placing the breaker into service, perform the inspections and tests required by the manufacturer’s instructions and applicable electrical standards.

Verify mechanical operation, electrical connections, protection settings, auxiliary circuits, and interlocking functions where applicable.

Do not energize the breaker until installation and commissioning checks have been completed.

Compatible System Components

The NW12N2 is typically installed as part of a larger low-voltage power distribution assembly.

Component Function Integration Considerations
Low-voltage switchboard Houses and connects distribution equipment Verify breaker dimensions, mounting, and busbar arrangement
Busbar system Distributes electrical power Confirm current rating, short-circuit withstand, and connection compatibility
Protection trip unit Detects abnormal electrical conditions Verify exact model, protection functions, and settings
Current sensors Provide current measurement for protection Match the sensor rating to the breaker and protection design
Auxiliary contacts Provide breaker status signals Confirm contact arrangement and control voltage
Shunt trip accessory Enables remote electrical tripping Verify accessory compatibility and control-circuit requirements
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the correct accessory and operating voltage
PLC or monitoring system Monitors breaker status and system conditions Check available auxiliary signals and communication hardware
Upstream protection device Provides coordinated supply protection Perform a protection coordination study
Downstream circuit breakers Protect outgoing distribution circuits Verify selectivity and fault coordination

These components are examples of equipment used in a complete distribution installation. They are not necessarily supplied with the NW12N2 breaker.

Alternative Models and Replacement Considerations

Schneider Electric’s Masterpact NW family includes several frame and interrupting-capacity options. Related models may be considered during maintenance or replacement planning, but they are not automatically interchangeable.

Related Model General Description Replacement Considerations
Masterpact NW08N 800 A UL W-frame family Lower frame-current class; not a direct substitute without system review
Masterpact NW12N 1200 A UL W-frame family Confirm exact variant, poles, sensor rating, and trip unit
Masterpact NW16N 1600 A UL W-frame family Higher frame-current class; verify switchboard and protection compatibility
Masterpact NW20N 2000 A UL W-frame family Requires a different current and switchboard assessment
Masterpact NW12H Related 1200 A high-interrupting-capacity UL family Verify interrupting rating and applicable standards
Masterpact NW12N1 Related IEC 1250 A W-frame designation Different catalog designation and rating framework; do not assume interchangeability

Before selecting a replacement, compare the following:

  • Complete catalog number and product generation.
  • Applicable UL or IEC standard.
  • Rated operational voltage.
  • Rated current and sensor rating.
  • Number of poles.
  • Short-circuit breaking capacity.
  • Trip-unit model and protection functions.
  • Fixed or drawout installation.
  • Busbar and terminal arrangement.
  • Mechanical interlocks and auxiliary accessories.
  • Dimensions, weight, and switchboard compatibility.

For critical distribution equipment, replacement should be based on a documented engineering review rather than physical similarity alone.

Key Advantages

High-Current Distribution Capability

The Masterpact NW family is designed for large low-voltage distribution applications. The NW12 family is associated with the 1200 A UL W-frame class.

Circuit Protection

The breaker is designed to interrupt abnormal current conditions within its specified ratings, helping protect electrical distribution equipment and connected circuits.

Industrial Switchboard Integration

Its large-frame design supports installation in appropriately engineered industrial and commercial switchboards.

Configurable Protection

The Masterpact NW platform offers different trip-unit and protection configurations. The actual functions available depend on the installed hardware.

Monitoring and Control Options

With compatible auxiliary accessories, breaker status and selected operating conditions can be integrated into supervisory monitoring systems.

Maintenance and Isolation Support

A correctly installed breaker provides switching and isolation capabilities that support electrical maintenance procedures.

Technical FAQs

1. What is the Schneider NW12N2?

The NW12N2 is identified as a Schneider Electric Masterpact NW circuit breaker. It belongs to the large-frame low-voltage power protection product category and is intended for industrial and commercial distribution systems.

2. What does NW12 mean?

NW12 is a frame designation used in the Masterpact NW family. Schneider’s UL selection information identifies the NW12N family with a 1200 A frame rating. The exact current rating of an individual breaker depends on its configuration and installed sensor.

3. Is the NW12N2 rated at 1200 A?

The NW12 family is associated with the 1200 A UL W-frame class. However, the exact rated current and sensor configuration of the NW12N2 should be confirmed from its nameplate and technical documentation.

4. What is the breaking capacity of the NW12N2?

The breaking capacity cannot be established reliably from the abbreviated model designation alone. Schneider offers different interrupting-capacity versions within the NW12 family. Check the complete catalog number, rated voltage, and applicable standard.

5. What is the difference between NW12N and NW12H?

These are different interrupting-capacity versions in the Masterpact NW family. Schneider’s UL selection information lists different short-circuit interrupting ratings for N and H versions. The correct choice depends on the prospective fault current and the installation’s protection requirements.

6. Can the NW12N2 be used as a main circuit breaker?

It may be used in a main distribution application if its electrical ratings, protection functions, and installation configuration meet the system requirements. A qualified engineer must verify the application.

7. Can the NW12N2 be integrated with a PLC?

Yes, breaker status and selected control functions can be integrated into an automation or monitoring system when suitable auxiliary contacts and accessories are installed. The exact signals depend on the breaker configuration.

8. What should be checked before purchasing?

Verify the nameplate, complete catalog number, rated voltage, sensor rating, pole count, interrupting capacity, trip unit, mounting type, physical condition, and included accessories.

9. What are the supplied dimensions and weight?

The supplied listing dimensions are 352 × 537 × 297 mm, and the supplied weight is 65 kg. Confirm the actual unit dimensions and whether the weight refers to the breaker alone or a packaged shipment.

10. Can another Masterpact NW12 model replace it?

Not automatically. Different NW12 variants may have different breaking capacities, standards, trip units, and connection configurations. A replacement must be checked against the original electrical and mechanical requirements.

Procurement and Maintenance Recommendations

When sourcing a Schneider NW12N2 circuit breaker, begin by confirming the complete product designation and the information on the nameplate. The NW12 family includes several variants, and differences in interrupting capacity, sensor rating, pole configuration, and mounting arrangement can affect whether a unit is suitable for a particular installation.

For used, refurbished, or surplus equipment, request clear photographs of the front label, trip unit, terminals, and operating mechanism. Confirm the mechanical condition, accessory configuration, and available inspection or test records.

For a replacement project, compare the electrical ratings and physical interfaces with the existing switchboard. Check busbar dimensions, connection positions, mounting arrangements, interlocks, and auxiliary circuits before ordering.

Routine maintenance should follow Schneider Electric’s instructions and the site’s electrical maintenance procedures. Inspection may include the operating mechanism, main contacts, terminals, insulation condition, trip-unit settings, and auxiliary circuits.

Any protection-setting changes or internal servicing should be performed by qualified personnel. For critical electrical distribution systems, document inspection results and retain the relevant commissioning and maintenance records.

Conclusion

The Schneider NW12N2 Masterpact NW Circuit Breaker is an industrial low-voltage power protection device intended for large electrical distribution systems. The Masterpact NW family provides circuit protection and switching functions for applications such as industrial switchboards, commercial facilities, and infrastructure power systems.

The NW12 family is associated with a 1200 A UL frame class, but the exact electrical characteristics of the NW12N2 must be verified from the complete catalog number and nameplate. Rated voltage, sensor rating, breaking capacity, trip-unit configuration, and mounting arrangement are essential selection factors.

For procurement and replacement projects, confirming both electrical and mechanical compatibility is critical to maintaining safe and reliable power distribution.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501