Product Overview The Schneider Electric NW10N2 Circuit Breaker is a low-voltage air circuit breaker (ACB) from the MasterPact NW family. It is designed for high-current electrical distribution systems t……
Schneider NW10N2 Circuit Breaker
  • Schneider
  • NW10N2
  • Circuit Breaker
  • France
  • 352 x 537 x 297 mm
  • 65 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider NW10N2 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider NW10N2 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider NW10N2 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider NW10N2 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric NW10N2 Circuit Breaker is a low-voltage air circuit breaker (ACB) from the MasterPact NW family. It is designed for high-current electrical distribution systems that require reliable switching, overload protection, and short-circuit protection. It can be used in industrial facilities, commercial buildings, power distribution rooms, and other installations where large electrical loads must be controlled and protected.

Air circuit breakers are commonly installed in main distribution boards, switchboards, and power control centers. They protect electrical circuits by detecting abnormal current conditions and opening the circuit when the configured protection thresholds are exceeded. Compared with smaller molded-case circuit breakers, large-frame ACBs provide a broader range of protection settings, accessories, and installation arrangements for demanding distribution applications.

The NW10N2 belongs to the MasterPact NW10 frame category, associated with a 1000 A frame rating. The N2 designation identifies a particular performance configuration within the MasterPact NW range. The complete protection characteristics, including the actual sensor rating, trip-unit configuration, and interrupting capacity, must be confirmed from the product nameplate and the applicable technical documentation.

The supplied dimensions are 352 × 537 × 297 mm, and the listed weight is 65 kg. These values correspond to the approximate dimensions and weight of a fixed-mounted, four-pole MasterPact NW08–NW16 circuit breaker configuration. The exact mounting arrangement and pole count should be verified before installation or replacement.

For industrial maintenance teams, the NW10N2 is relevant to applications where an existing MasterPact NW circuit breaker must be maintained or replaced. Correct identification is essential because breakers in the same product family can differ in rated current, interrupting performance, trip-unit options, pole configuration, and mounting arrangement.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series MasterPact NW
Model NW10N2
Product Type Air Circuit Breaker
Product Category Low-Voltage Power Circuit Breaker
Frame Category NW10
Frame Rating 1000 A
Performance Designation N2
Mounting Configuration Verify exact unit; supplied dimensions correspond to fixed 4-pole configuration
Dimensions Provided 352 × 537 × 297 mm
Weight Provided 65 kg
Typical Installation Main distribution boards and industrial switchboards
Main Protection Functions Overload and short-circuit protection, according to installed trip unit
Trip Unit Depends on the complete breaker configuration
Pole Configuration Verify nameplate; supplied dimensions correspond to 4-pole configuration
Product Family MasterPact NW

Important: The NW10 frame designation indicates the 1000 A frame category; it does not by itself establish the installed sensor rating or trip setting. Confirm the complete catalog reference, trip unit, rating plug, pole count, and breaking capacity from the actual unit before specifying or installing the breaker.

Function and Working Principle

The NW10N2 is designed to protect low-voltage electrical distribution circuits against abnormal operating conditions. Its operation combines current detection, protective decision-making, and a mechanical switching mechanism.

1. Overload Protection

An overload occurs when a circuit carries more current than its permitted operating level for an extended period. Prolonged overloads can cause excessive heating in conductors, busbars, transformers, and connected equipment.

The breaker uses its installed trip unit to monitor current and determine whether an overload condition requires interruption. The protection settings depend on the trip-unit type and the configured rating.

For industrial power distribution, the overload settings must be coordinated with cable capacity, transformer characteristics, downstream protective devices, and the overall electrical design.

2. Short-Circuit Protection

A short circuit can cause a rapid and substantial increase in current. If the fault is not interrupted promptly, it can create severe thermal and electrodynamic stress on electrical equipment.

The MasterPact NW protection system is designed to detect fault-current conditions and initiate circuit interruption according to the installed protection configuration.

The required short-circuit performance must be checked against the prospective fault current at the installation point. The N2 designation should not be used as a substitute for verifying the breaker’s actual interrupting rating at the system voltage.

3. Circuit Switching

In addition to protection, an ACB provides a means of switching electrical distribution circuits. Depending on its installed accessories and control arrangement, the breaker may support local operation and remote switching functions.

This capability is useful in main distribution systems where operators need to isolate equipment for maintenance or coordinate the operation of multiple power sources.

Switching procedures must follow the electrical installation’s operating rules and safety requirements.

4. Trip Unit Operation

The trip unit is a critical part of the circuit breaker’s protection system. It monitors current and evaluates abnormal conditions according to its configured settings.

Depending on the installed trip-unit type, protection functions may include long-time, short-time, instantaneous, and ground-fault protection.

Not every NW10N2 assembly necessarily has the same trip unit or protection options. Maintenance personnel should inspect the installed unit and record its exact type and settings before replacing the breaker.

5. Arc Interruption

When the breaker opens under load or fault conditions, an electrical arc may form between the separating contacts. The ACB’s arc-control and interruption system is designed to extinguish this arc and isolate the circuit.

Proper maintenance of the switching mechanism and contact system is important for dependable operation. Inspection and servicing must follow Schneider Electric’s applicable maintenance procedures.

Role in Industrial Power Distribution Systems

The NW10N2 can serve as a major switching and protection device in low-voltage distribution installations. It is generally used where high-current circuits require coordinated protection and controlled isolation.

Main Incoming Feeder Protection

In a main distribution board, the breaker may be installed as the incoming protective device between a transformer or upstream supply and the main busbar system.

It helps protect the downstream distribution network against overload and short-circuit conditions. Its protection settings should be coordinated with the upstream and downstream protective devices.

Bus Coupler Applications

Some electrical distribution systems use two or more busbar sections connected through a bus coupler. A circuit breaker can control the connection between these sections.

In such arrangements, the breaker may be incorporated into an electrical interlocking and control scheme to support safe switching and power distribution flexibility.

The specific role of an NW10N2 depends on the switchboard design and its installed accessories.

Feeder Protection

The breaker may also be used to protect a high-current feeder supplying industrial equipment, distribution panels, or large electrical loads.

Its protective characteristics must match the connected circuit and the available fault current. Coordination with downstream breakers is important to reduce unnecessary interruption of the wider electrical system.

Generator and Transformer Distribution

Large generators and transformers are often connected to low-voltage distribution systems through appropriately rated circuit breakers.

An ACB can provide switching and protection functions in these arrangements, but generator protection and transformer protection require application-specific settings and coordination. The NW10N2 should only be used where its verified electrical ratings and protection configuration meet the system design.

Industrial Applications

1. Manufacturing Plants

Manufacturing facilities often operate large motors, production machinery, compressors, pumps, and auxiliary systems. A main distribution breaker helps protect the electrical infrastructure supplying these loads.

The MasterPact NW family is designed for distribution applications where high-current switching and protection are required.

2. Power Distribution Rooms

Industrial power distribution rooms use main and feeder circuit breakers to divide electrical power among different sections of a facility.

The NW10N2 can be considered for a suitable high-current distribution position when its electrical ratings, installation arrangement, and protection settings match the switchboard design.

3. Data Centers

Data centers require carefully coordinated electrical distribution systems to supply servers, cooling equipment, UPS systems, and other critical infrastructure.

Large-frame ACBs may be used in main switchboards and distribution sections. Correct protection coordination is important to limit the impact of electrical faults and maintain continuity of supply.

4. Infrastructure Facilities

Water treatment plants, transportation facilities, commercial complexes, and other infrastructure installations may use large-frame air circuit breakers in their low-voltage distribution networks.

The breaker helps provide controlled isolation and protection for high-current circuits.

5. Utility and Industrial Substations

Low-voltage sections of substations may use ACBs to control and protect outgoing feeders and distribution busbars.

Selection must consider system voltage, available short-circuit current, installation environment, and the coordination requirements of the complete protection scheme.

Installation and System Integration

The correct installation of the NW10N2 is essential for electrical safety and reliable operation.

1. Verify the Complete Breaker Configuration

Before installation, check the complete catalog number and nameplate. Confirm the frame category, actual current rating, pole count, trip-unit model, sensor rating, and interrupting capacity.

The NW10 frame category alone does not establish every electrical characteristic of the assembled breaker.

2. Confirm Panel Dimensions and Mounting

The supplied dimensions are 352 × 537 × 297 mm, with a listed weight of 65 kg. These values correspond to a fixed-mounted, four-pole configuration in the relevant MasterPact NW frame range.

Before designing or modifying a switchboard, verify the exact manufacturer’s dimensional drawing and the installed mounting arrangement. Fixed and drawout versions have different dimensions and weights.

The breaker is a heavy electrical component. Use suitable lifting equipment and approved handling procedures during transportation and installation. Ensure that the supporting structure and mounting hardware are designed for the actual unit weight.

3. Check Busbar and Terminal Connections

Busbar connections must be designed for the rated current and expected thermal and electrodynamic forces. Check conductor size, connection surfaces, clearances, terminal arrangements, and tightening requirements.

Incorrect connections can lead to overheating, excessive contact resistance, and equipment damage.

4. Configure the Protection System

The installed trip unit and its settings must be appropriate for the electrical system. Engineers should review long-time, short-time, instantaneous, and ground-fault functions where available.

Protection coordination should consider the transformer, upstream protective device, downstream feeders, cable ratings, and prospective fault current.

5. Connect Auxiliary Circuits

Depending on the installed accessories, the breaker may support auxiliary status contacts, shunt opening, undervoltage release, motorized operation, or other control functions.

Verify the exact accessories fitted to the unit before designing the control wiring. Do not assume that every MasterPact NW breaker includes the same auxiliary functions.

6. Perform Commissioning Checks

Before energizing the breaker, inspect mechanical mounting, busbar connections, insulation condition, control wiring, and grounding arrangements.

Verify the breaker’s mechanical operation and protective settings according to the manufacturer’s commissioning instructions. Testing should be performed by qualified personnel using appropriate equipment and documented procedures.

Compatible System Components

The NW10N2 may be integrated with a range of electrical distribution and control components. Actual compatibility depends on the breaker version, trip unit, accessories, and switchboard design.

Component Function Integration Considerations
Low-voltage switchboard Houses and distributes electrical power Verify mounting dimensions, clearances, and busbar arrangement
Main busbar system Distributes current to multiple feeders Confirm current capacity and connection requirements
Micrologic trip unit Provides electronic protection and monitoring where fitted Verify exact trip-unit model and available functions
Auxiliary contacts Provide breaker status signals Confirm contact type and terminal arrangement
Shunt release Enables electrical opening control Check coil voltage and accessory compatibility
Undervoltage release Opens the breaker when supply voltage falls below its operating threshold Confirm voltage rating and control arrangement
Motor mechanism Supports electrically operated charging or switching functions where fitted Verify the installed accessory and control voltage
PLC or power management system Coordinates monitoring and control Requires compatible auxiliary contacts or communication accessories
Current transformers or sensors Provide current measurement for protection Confirm the installed sensing and trip-unit arrangement
Upstream transformer Supplies the low-voltage distribution system Check rated current and short-circuit coordination

The table describes possible system components, not a list of accessories included with every NW10N2 breaker.

Alternative Models and Replacement Considerations

The MasterPact NW family includes multiple frame sizes and performance configurations. A replacement must be selected according to the complete electrical and mechanical requirements of the installation.

Alternative or Related Model Considerations
MasterPact NW10N1 Same NW10 frame category but a different performance designation; verify interrupting capacity and application suitability
MasterPact NW10H1 Higher-performance configuration within the NW10 family; check exact ratings and system requirements
MasterPact NW10H2 Different breaking-performance configuration; not automatically interchangeable
MasterPact NW12 series Larger frame category; requires verification of current rating, dimensions, and switchboard compatibility
Current-generation Schneider Electric MasterPact range May be considered for an upgrade, but mechanical, electrical, and accessory compatibility must be assessed

Before selecting a replacement, compare:

  • Frame rating and actual sensor rating.
  • Rated operational voltage.
  • Rated current and trip settings.
  • Short-circuit breaking capacity at the system voltage.
  • Number of poles.
  • Fixed or drawout mounting arrangement.
  • Trip-unit model and protection functions.
  • Auxiliary contacts and control accessories.
  • Busbar and terminal connection arrangement.
  • Dimensions, weight, and switchboard mounting requirements.

A breaker with the same frame category is not necessarily a direct replacement. Changes in trip-unit design, mounting dimensions, accessories, or protection performance may require switchboard modifications and a revised protection study.

Key Advantages

High-Current Distribution Capability

The NW10 frame category is designed for high-current low-voltage distribution applications, with a 1000 A frame rating.

Integrated Circuit Protection

The breaker can provide overload and short-circuit protection according to its installed trip-unit configuration.

Industrial Switching Functionality

The MasterPact NW family supports switching and isolation applications in industrial and commercial distribution systems.

Configurable Protection

Different trip-unit and accessory configurations allow the breaker to be adapted to specific distribution requirements.

Flexible Installation Arrangements

The MasterPact NW range includes fixed and drawout configurations. The exact installation arrangement must be confirmed for the specific unit.

Suitable for Critical Distribution Systems

When correctly selected and coordinated, a large-frame ACB can form an important part of the protection architecture in manufacturing plants, infrastructure facilities, and other high-current installations.

Technical FAQs

1. What is the Schneider Electric NW10N2?

The NW10N2 is a MasterPact NW low-voltage air circuit breaker designed for high-current electrical distribution and circuit protection.

2. What does NW10 mean?

NW10 identifies the frame category associated with a 1000 A frame rating. The actual sensor rating and trip settings must be checked on the assembled breaker.

3. What does the N2 designation mean?

N2 identifies a particular performance configuration within the MasterPact NW family. The exact breaking capacity must be confirmed from the applicable product documentation and breaker nameplate.

4. What is the weight of the NW10N2?

The supplied listing weight is 65 kg. This corresponds to the approximate weight of a fixed-mounted four-pole configuration in the relevant MasterPact NW frame range.

5. What are the dimensions of this circuit breaker?

The supplied dimensions are 352 × 537 × 297 mm. Verify the manufacturer’s dimensional drawing before designing the switchboard or planning a replacement.

6. Is the NW10N2 a fixed or drawout circuit breaker?

The supplied dimensions and weight correspond to a fixed-mounted four-pole configuration. However, the actual mounting arrangement should be verified from the product nameplate and physical unit.

7. What protection functions does it provide?

The breaker provides circuit protection through its installed trip unit. Depending on the trip-unit model and settings, protection functions may include long-time, short-time, instantaneous, and ground-fault protection.

8. Can the NW10N2 be used as a main incoming breaker?

It may be suitable for a main incoming position when its voltage, current, interrupting capacity, trip-unit configuration, and installation arrangement meet the electrical system requirements.

9. Can it replace another MasterPact NW10 breaker?

Not automatically. Confirm the performance designation, pole count, mounting arrangement, trip unit, accessories, terminal connections, and electrical ratings before substitution.

10. What should be checked before purchasing a used NW10N2?

Inspect the nameplate, breaker frame, contacts, operating mechanism, trip unit, accessories, and terminal condition. Request available test records and verify the breaker’s mechanical and electrical condition before using it in a critical distribution system.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric NW10N2, verify the full model designation and the actual configuration of the breaker. The NW10 frame category, N2 performance designation, pole count, trip unit, sensor rating, and mounting arrangement should all be confirmed.

For replacement projects, compare the existing breaker with the proposed unit using the manufacturer’s drawings and electrical specifications. Pay particular attention to the breaking capacity, protection settings, busbar connections, and switchboard dimensions.

For used or surplus equipment, request clear photographs of the nameplate, trip unit, front panel, terminals, and operating mechanism. Confirm whether auxiliary accessories are included and whether the breaker has undergone functional testing.

Routine maintenance should follow the manufacturer’s recommended procedures. Inspection may include mechanical operation, contact condition, terminal connections, insulation, auxiliary circuits, and trip-unit testing. Any work involving high-current switchgear must be performed by qualified personnel under appropriate isolation and safety procedures.

Conclusion

The Schneider Electric NW10N2 MasterPact NW is a low-voltage air circuit breaker designed for high-current industrial and commercial power distribution systems. Its NW10 frame category is associated with a 1000 A frame rating, while the N2 designation identifies a particular performance configuration.

With supplied dimensions of 352 × 537 × 297 mm and a listed weight of 65 kg, this configuration corresponds to a fixed-mounted four-pole MasterPact NW arrangement. Accurate verification of the trip unit, sensor rating, breaking capacity, pole count, and mounting details is essential when purchasing or replacing the breaker.

For industrial maintenance and electrical distribution projects, checking the complete product configuration helps ensure that the NW10N2 is correctly matched to the switchboard and the protection requirements of the installation.