Product Overview The Schneider Electric MT08H1b Masterpact Air Circuit Breaker (ACB) is a low-voltage circuit protection device designed for high-current power distribution systems. It belongs to the Ma……
Schneider MT08H1b Circuit Breaker
  • Schneider
  • MT08H1b
  • Circuit Breaker
  • France
  • 439 x 556 x 395 mm
  • 70 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

Schneider MT08H1b Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT08H1b Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT08H1b Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT08H1b Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MT08H1b Masterpact Air Circuit Breaker (ACB) is a low-voltage circuit protection device designed for high-current power distribution systems. It belongs to the Masterpact MT family and is used in industrial switchgear, main distribution panels, and electrical installations where reliable protection and controlled power isolation are essential.

With an 800 A rated current and an H1b interrupting class, the MT08H1b is designed for demanding power distribution applications. Circuit breakers in this category protect electrical equipment and distribution circuits against abnormal current conditions, including overloads and short circuits. When a fault occurs, the protection mechanism detects the abnormal condition and initiates circuit interruption to help limit damage to connected equipment.

The MT08H1b is associated with a high-interrupting-capacity configuration. Published model information identifies an 800 A rating and an approximately 85 kA ultimate short-circuit breaking capacity for the H1b version. The actual breaking capacity depends on the applicable standard, operating voltage, and complete breaker configuration.

The Masterpact MT platform can be configured with different trip units, pole arrangements, mounting styles, and accessories. Micrologic trip units provide electronic protection functions and allow the breaker to respond to electrical operating conditions. The specific trip unit installed on an individual MT08H1b should be confirmed from its nameplate and equipment documentation.

This circuit breaker is intended for use in properly designed low-voltage distribution systems. It is particularly relevant to industrial facilities where high-current feeders, main distribution circuits, and large electrical loads require coordinated protection.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Series Masterpact MT
Model MT08H1b
Product Type Air Circuit Breaker (ACB)
Rated Current 800 A
Interrupting Class H1b
Ultimate Breaking Capacity Approximately 85 kA, subject to rated voltage and applicable standard
Trip Unit Micrologic electronic trip unit; verify installed version
Referenced Trip Unit Configuration Micrologic 2.0A
Protection Function Overload and short-circuit protection, according to installed trip unit
Application Low-voltage power distribution
Dimensions Provided 439 × 556 × 395 mm
Weight Provided 70 kg
Installation Confirm fixed or draw-out configuration from the actual unit
Pole Configuration Confirm from the nameplate and product configuration
Typical Equipment Main distribution boards, industrial switchgear, feeder protection

Note: The MT08H1b model designation identifies the breaker frame and interrupting class, but does not by itself establish every electrical and mechanical option. Verify rated operational voltage, pole count, trip-unit details, mounting arrangement, and accessory configuration before installation.

Function and Working Principle

The MT08H1b is designed to protect electrical distribution circuits by monitoring current and interrupting the circuit when specified abnormal conditions occur. Its operation combines current sensing, protection logic, and a mechanical switching mechanism.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating level for a sustained period. Excessive current can cause conductors, busbars, transformers, and connected equipment to overheat.

The installed Micrologic trip unit monitors current and evaluates it against the configured protection characteristics. When an overload condition meets the trip criteria, the breaker initiates an opening operation to disconnect the affected circuit.

Correct protection settings are important. The long-time protection parameters must be coordinated with the cable capacity, downstream equipment, and system operating requirements.

2. Short-Circuit Protection

A short circuit can produce a rapid and substantial increase in current. If the fault is not interrupted quickly, the resulting thermal and electrodynamic forces can damage electrical equipment.

The MT08H1b’s H1b interrupting class is intended for high fault-current applications. The published approximately 85 kA figure is an ultimate breaking-capacity value associated with the H1b version, not a universal rating at every voltage.

Engineers must confirm the prospective short-circuit current at the installation point and compare it with the breaker rating at the actual system voltage.

3. Electronic Trip Unit Operation

The Micrologic trip unit provides electronic monitoring and protection functions. Depending on the installed version, it can evaluate current conditions and initiate a trip when the configured protection limits are exceeded.

The referenced Micrologic 2.0A configuration is associated with basic electronic overcurrent protection. The exact available settings and protection functions should be checked against the installed trip-unit documentation.

4. Circuit Interruption

When the protection system identifies a fault requiring interruption, the trip mechanism releases the operating mechanism. The breaker contacts separate, and the internal arc-control arrangement helps extinguish the electrical arc generated during interruption.

The breaker is designed to interrupt current within its specified operating and breaking limits. Correct selection requires consideration of system voltage, available fault current, power-system configuration, and coordination with upstream and downstream protective devices.

5. Manual Switching and Isolation

In addition to automatic protection, an air circuit breaker provides switching functionality for electrical distribution systems. Authorized personnel can operate the breaker according to the equipment’s operating procedures.

For maintenance, the breaker must be placed in the correct isolated condition and all applicable electrical safety procedures must be followed. A breaker in the open position should not automatically be assumed to provide safe isolation without verifying the equipment’s actual isolation and interlocking arrangement.

Role in Industrial Power Distribution Systems

The MT08H1b can serve as a main or feeder protection device in industrial low-voltage distribution systems. Its role depends on the switchgear architecture and the protection coordination study.

Main Incoming Circuit Protection

In a main distribution board, an ACB may be installed on the incoming supply to protect the main busbar system and downstream distribution circuits.

The 800 A rating makes the MT08H1b relevant to installations whose calculated operating current and protection requirements are compatible with this rating. Final selection must also account for load diversity, conductor ratings, and system fault levels.

Feeder Protection

The breaker can also be used to protect an individual feeder supplying a major load or a downstream distribution panel.

A properly coordinated feeder breaker helps isolate a faulted section while allowing unaffected parts of the electrical installation to remain in operation where the protection scheme permits.

Coordination with Protection Systems

Industrial distribution systems often contain multiple protective devices arranged in series. Their settings must be coordinated so that the protective device closest to a fault operates where possible.

Coordination requires consideration of long-time, short-time, instantaneous, and other applicable protection characteristics. The exact functions available depend on the installed Micrologic trip unit.

Integration with Electrical Monitoring

Depending on the installed accessories and trip-unit configuration, the breaker may form part of a wider electrical monitoring and control arrangement.

Additional functions such as remote indication, auxiliary status signals, or communication-based monitoring require the appropriate accessories and compatible system components. They should not be assumed to be included with every MT08H1b unit.

Industrial Applications

The Schneider Electric MT08H1b is designed for low-voltage power distribution applications requiring high-current circuit protection.

1. Industrial Main Distribution Boards

Manufacturing facilities use main distribution boards to receive and distribute electrical power to production areas, machinery, and auxiliary systems.

An 800 A air circuit breaker may be used where the incoming or feeder circuit requirements match its electrical ratings. Its high-interrupting-capacity class is relevant when the available fault current is substantial.

2. Manufacturing Plants

Industrial production facilities operate motors, machine tools, heating equipment, compressors, and automated production lines. These loads place significant demands on the electrical distribution system.

The MT08H1b can be incorporated into a suitably engineered switchgear assembly to protect an incoming supply or major feeder.

3. Power Distribution Rooms

Commercial and industrial buildings often use centralized electrical distribution rooms containing main switchgear and feeder panels.

The breaker can provide protection and switching functionality for compatible distribution circuits. The installation must provide suitable busbar connections, enclosure clearances, ventilation, and safe operating access.

4. Data Centers and Critical Facilities

Data centers require carefully designed electrical distribution systems to supply servers, cooling equipment, UPS systems, and other critical loads.

An ACB may be used in a main or secondary distribution position where its ratings and protection characteristics match the electrical design. Reliability depends on the complete power architecture, including redundancy, protective coordination, maintenance arrangements, and backup power systems.

5. Infrastructure and Utility Installations

Infrastructure facilities such as water treatment plants, transportation facilities, and large commercial complexes require dependable low-voltage distribution.

The MT08H1b may be considered for suitable high-current distribution duties where the breaker ratings, installation environment, and operating requirements are compatible.

Installation and System Integration

The installation of an 800 A air circuit breaker requires careful electrical and mechanical planning. It should be carried out by qualified personnel familiar with the relevant switchgear and electrical safety requirements.

1. Verify Electrical Ratings

Before installation, confirm the system’s nominal voltage, frequency, rated current, and prospective short-circuit current.

The 800 A current rating must be suitable for the protected circuit and its conductors. The H1b interrupting class must also be checked against the manufacturer’s breaking-capacity data at the actual operating voltage.

Do not assume that the approximately 85 kA figure applies at every voltage or under every standard.

2. Check the Mechanical Configuration

Confirm whether the actual breaker is fixed-mounted or draw-out. These arrangements have different installation requirements and may use different supporting structures and connection interfaces.

For a draw-out arrangement, verify the compatibility of the breaker body, cradle, guide rails, primary contacts, and interlocking components.

3. Verify the Trip Unit

Inspect the installed Micrologic trip unit and confirm its model, protection functions, and available settings.

Before energizing the breaker, verify that protection settings are consistent with the electrical design and the coordination study. Incorrect settings may cause unwanted trips or inadequate protection.

4. Busbar and Cable Connections

The busbar and cable connections must be suitable for the rated current and short-circuit stresses of the installation.

Check connection surfaces, contact condition, conductor sizing, and tightening requirements. Follow the manufacturer’s specified torque values and installation procedures.

5. Grounding and Switchgear Design

The switchgear assembly must have a suitable protective grounding arrangement. Ensure that the breaker is installed in an enclosure designed for its mechanical dimensions, electrical ratings, and required operating clearances.

The supplied dimensions of 439 × 556 × 395 mm should be checked against the actual unit and manufacturer’s dimensional drawings before panel fabrication or replacement planning.

6. Functional Testing and Commissioning

Before the breaker is placed into service, perform the required inspection and testing procedures. These may include mechanical operation checks, trip-unit verification, contact-resistance testing, insulation testing where appropriate, and confirmation of auxiliary circuits.

Testing must follow the manufacturer’s instructions and the relevant electrical safety standards. Record the final protection settings and commissioning results for future maintenance.

Compatible System Components

The MT08H1b is normally installed as part of a complete switchgear and power distribution assembly. The following components may be relevant, depending on the breaker configuration.

Component Function Compatibility Considerations
Micrologic trip unit Electronic current monitoring and protection Verify the exact installed version and supported functions
Circuit breaker cradle Supports a compatible draw-out breaker Match the cradle to the exact frame and model
Main busbars Carry current through the switchgear assembly Verify current rating, short-circuit withstand, and connection geometry
Auxiliary contacts Provide breaker status signals Confirm contact type and accessory compatibility
Shunt trip accessory Enables electrical remote tripping Verify coil voltage and accessory compatibility
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the correct accessory and rated control voltage
Closing release Supports electrical closing operation Verify the operating voltage and control-circuit design
Switchgear enclosure Houses and protects the breaker Check dimensions, mounting arrangement, clearances, and environmental conditions
Power monitoring system Monitors electrical operating conditions Requires compatible sensing, communication, and monitoring accessories

Not all components listed above are included with the MT08H1b. The actual accessory arrangement should be checked before purchasing replacement equipment.

Alternative Models and Replacement Considerations

When replacing an MT08H1b, engineers should evaluate both the electrical ratings and mechanical installation requirements. A breaker with a similar current rating may not provide equivalent protection or fit the existing switchgear.

Alternative or Related Model Considerations
Schneider Masterpact MT08H1 Related 800 A frame with a different interrupting class; verify fault-current requirements
Schneider Masterpact MT08H2 Higher interrupting class in the MT family; check voltage-specific ratings and configuration
Schneider Masterpact MT08N1 Related 800 A frame with a different breaking-capacity class
Schneider Masterpact MTZ range A newer product family that may be considered for modernization, subject to engineering evaluation
Other 800 A low-voltage ACBs Must be evaluated for electrical ratings, dimensions, trip characteristics, and switchgear compatibility

Before approving a replacement, compare:

  • Rated operational voltage.
  • Rated current and frame rating.
  • Ultimate and service short-circuit breaking capacities.
  • Pole configuration.
  • Trip-unit model and protection functions.
  • Fixed or draw-out mounting arrangement.
  • Busbar and terminal connection dimensions.
  • Auxiliary contacts and electrical accessories.
  • Mechanical interlocks and closing arrangements.
  • Switchgear dimensions and installation clearances.

A replacement project may require modifications to the switchgear, busbar connections, control wiring, protection settings, and commissioning procedures.

Key Advantages

High-Current Protection

The 800 A rating makes the MT08H1b suitable for compatible high-current distribution circuits in industrial and commercial installations.

High Interrupting Capacity

The H1b version is associated with an approximately 85 kA ultimate breaking-capacity rating in published model data. The applicable rating must be confirmed at the actual system voltage.

Electronic Protection

The Micrologic trip-unit platform provides electronic overcurrent monitoring and configurable protection functions according to the installed version.

Industrial Switchgear Integration

The Masterpact MT platform is designed for integration into low-voltage switchgear and distribution assemblies.

Main and Feeder Applications

The breaker can be applied to main incoming or feeder protection duties where the electrical design and equipment ratings are suitable.

Maintenance and Replacement Use

The MT08H1b remains relevant to maintenance and replacement work involving existing Masterpact MT installations. Accurate identification of the trip unit, mounting arrangement, and accessories helps reduce compatibility problems.

Technical FAQs

1. What is the Schneider Electric MT08H1b?

The MT08H1b is a Masterpact MT low-voltage air circuit breaker designed for high-current power distribution and circuit protection applications.

2. What is the rated current of the MT08H1b?

The model is listed with an 800 A rated current.

3. What does H1b mean?

H1b identifies an interrupting-capacity class within the Masterpact MT product family. Published model data associates the MT08H1b with an approximately 85 kA ultimate breaking-capacity rating. The applicable value depends on the rated voltage and standard.

4. What is the difference between MT08H1 and MT08H1b?

Both models are associated with an 800 A frame rating, but they have different interrupting classes. Published comparison data lists approximately 65 kA for MT08H1 and 85 kA for MT08H1b. Always consult the manufacturer’s voltage-specific rating tables before selecting a breaker.

5. What trip unit can be used with the MT08H1b?

Micrologic electronic trip units are associated with the Masterpact MT platform. A Micrologic 2.0A configuration is listed in model-related equipment information, but the exact trip unit on an individual breaker must be verified.

6. Can the MT08H1b be used as a main circuit breaker?

It may be used as a main breaker in a suitable low-voltage distribution system if its current rating, interrupting capacity, pole arrangement, and protection characteristics match the system design.

7. Is the MT08H1b suitable for draw-out switchgear?

Masterpact MT breakers are available in different mechanical arrangements. The exact mounting type of the unit must be checked before selecting a replacement cradle or planning installation.

8. What should be checked before purchasing a replacement?

Confirm the complete model designation, rated current, voltage, interrupting class, trip-unit model, pole count, mounting arrangement, and accessory configuration. Photographs of the nameplate and terminal connections can help with identification.

9. Can an MT08H1b replace an MT08H1?

Not automatically. Although both are 800 A models, their interrupting classes differ. The replacement must meet the installation’s short-circuit requirements and be mechanically and electrically compatible with the switchgear.

10. What maintenance is required?

Maintenance should follow the manufacturer’s instructions and the applicable electrical safety standards. Typical activities include visual inspection, contact and connection checks, mechanical operation tests, trip-unit verification, and appropriate electrical testing.

Procurement and Maintenance Recommendations

When purchasing the Schneider Electric MT08H1b, verify the complete model designation and inspect the breaker nameplate. Confirm the 800 A rating, H1b interrupting class, installed Micrologic trip unit, pole configuration, and mechanical mounting arrangement.

For used or refurbished units, request clear photographs of the front panel, nameplate, terminals, operating mechanism, and trip unit. Ask for available inspection or test records, and confirm the equipment’s operating condition and warranty terms.

The supplied dimensions are 439 × 556 × 395 mm, with a listed weight of 70 kg. These values should be checked against the physical breaker and its shipping configuration. For transportation, use suitable lifting equipment and follow the manufacturer’s handling instructions because an air circuit breaker of this size is heavy electrical equipment.

For maintenance, inspect the breaker and its switchgear environment according to the manufacturer’s recommended schedule. Check for abnormal heating, damaged insulation, contamination, loose connections, mechanical wear, and signs of deterioration. Verify protection settings after maintenance or replacement and retain the test records.

When planning a modernization project, evaluate whether the existing switchgear can accommodate a replacement breaker. Changes in frame dimensions, mounting interfaces, busbar connections, protection functions, and accessories may require modifications to the electrical assembly.

Conclusion

The Schneider Electric MT08H1b Masterpact Air Circuit Breaker is an 800 A low-voltage circuit protection device intended for industrial and commercial power distribution systems. Its H1b interrupting class is associated with an approximately 85 kA ultimate breaking-capacity rating in published model information, while the installed Micrologic trip unit provides electronic overcurrent protection according to its configuration.

For industrial maintenance, switchgear replacement, and power distribution projects, correct identification of the complete breaker configuration is essential. Rated voltage, short-circuit capacity, trip-unit type, pole arrangement, mounting style, and accessories should all be verified before installation or substitution.