• Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver
  • Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver
  • Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver
  • Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver
Product Overview The Honeywell 2MLR-DBDH is a TP/FO Hybrid Redundant Expansion Driver for the MasterLogic-200R PLC system. It provides the communication interface between the redundant CPU system and re……
Honeywell 2MLR-DBDH MasterLogic-200 Redundant Expansion Driver
  • Honeywell
  • 2MLR-DBDH
  • Redundant Expansion Driver
  • USA
  • 150 × 25 × 100 mm
  • 0.1 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell 2MLR-DBDH MasterLogic-200 Redundant  Expansion Driver

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Honeywell 2MLR-DBDH is a TP/FO Hybrid Redundant Expansion Driver for the MasterLogic-200R PLC system. It provides the communication interface between the redundant CPU system and remote I/O expansion bases, supporting the dual I/O link architecture used in redundant automation installations.

Unlike the 2MLR-DBDT and 2MLR-DBDF, which use a single specified communication medium, the 2MLR-DBDH belongs to the hybrid communication configuration. TP (Twisted Pair) and FO (Fiber Optic) communication are both supported within this arrangement, allowing the expansion network to accommodate different transmission media according to the system configuration.

This is particularly useful in industrial plants where the main controller and remote I/O cabinets are installed in different areas. For example, a production facility may use twisted-pair cabling for nearby expansion cabinets while using fiber-optic connections for more distant equipment locations. The hybrid driver supports this type of mixed communication arrangement within the MasterLogic-200R redundant expansion architecture.

The 2MLR-DBDH is installed in the designated expansion-driver position of the 2MLR-E12H redundant expansion base. It works with the controller, expansion base, communication cabling, and I/O modules to maintain the connection between the central PLC and distributed field signals.

When selecting this module, the communication configuration is more important than its physical similarity to other expansion drivers. The 2MLR-DBDH, 2MLR-DBDT, and 2MLR-DBDF belong to the same redundant expansion-driver family, but their communication interfaces are different. Replacement selection should follow the existing network design and the required TP/FO arrangement.


Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 2MLR-DBDH
Product Series MasterLogic-200
System Type MasterLogic-200R
Product Type Redundant Expansion Driver
Module Category Redundant Expansion Driver Module
Communication Interface TP/FO Hybrid
Communication Media Twisted Pair and Fiber Optic
Network Configuration Dual I/O Link Redundancy
Installation Position Redundant Expansion Driver Connector
Compatible Expansion Base 2MLR-E12H
Current Consumption 550 mA
Dimensions 150 × 25 × 100 mm
Weight 0.1 kg

Product Features

  • Hybrid Communication Interface: Supports both twisted-pair and fiber-optic communication within the specified system arrangement.
  • Redundant Expansion Architecture: Belongs to the MasterLogic-200R dual I/O link redundancy hardware family.
  • Mixed Transmission Media: Accommodates network configurations involving TP and FO communication.
  • Remote I/O Connectivity: Supports communication between the redundant CPU system and distributed expansion bases.
  • Dedicated Expansion Driver: Installs in the designated position on the 2MLR-E12H redundant expansion base.
  • Industrial Network Integration: Supports distributed I/O arrangements in industrial control installations.
  • Communication Configuration Flexibility: Provides a hybrid alternative to the dedicated TP and FO driver variants.
  • Modular PLC Architecture: Works with the MasterLogic-200R expansion hardware and compatible I/O modules.
  • Dedicated Model Identification: Distinguishes the hybrid redundant driver from 2MLR-DBDT and 2MLR-DBDF.
  • Maintenance Replacement: Provides a specific replacement reference for existing TP/FO redundant expansion installations.

Product Working Principle

The 2MLR-DBDH functions as the communication interface within the MasterLogic-200R redundant expansion network. Its main responsibility is to support data exchange between the controller and remote I/O assemblies using the configured TP/FO communication arrangement.

The basic system connection is:

MasterLogic-200R CPU → Redundant Expansion Network → 2MLR-DBDH → 2MLR-E12H Expansion Base → I/O Modules → Field Devices

The hybrid configuration accommodates two different transmission media:

  • TP (Twisted Pair): Uses copper-based communication cabling for electrical data transmission.
  • FO (Fiber Optic): Uses optical fiber to transmit data through light signals.

These media have different transmission characteristics. Twisted-pair connections are suitable for compatible electrical communication links, while fiber-optic connections are useful where longer transmission distances or greater resistance to electromagnetic interference are required.

During normal operation, the CPU exchanges process information with the remote I/O system. Input modules collect signals from connected instruments, including pressure transmitters, temperature sensors, and equipment status contacts. The expansion communication network transfers this information to the controller.

The CPU processes the incoming data and sends the corresponding output commands to the remote I/O modules. These modules then control connected equipment such as valves, motor starters, and other field devices.

The redundant expansion architecture uses dual I/O communication links. The 2MLR-DBDH supports the hybrid communication arrangement within this architecture. Actual communication paths and their operating behavior depend on the system’s cabling and configuration.

The module does not independently execute PLC programs or convert field analog signals. Its role is to maintain the communication interface between the redundant controller and the expansion I/O hardware.


Role in Honeywell MasterLogic-200R Control System Architecture

The 2MLR-DBDH occupies the redundant expansion-driver position in the MasterLogic-200R control architecture. It connects the redundant expansion base to the communication network used by the main controller.

Its hybrid interface is particularly relevant when the installation requires both copper and optical communication media. This can occur in plants where local and remote I/O cabinets have different cable-routing conditions.

MasterLogic-200R CPU → Main Base → Redundant I/O Communication Network → 2MLR-DBDH → 2MLR-E12H Expansion Base → I/O Modules → Field Devices

System Component Function
2MLR-CPUH/T Redundant CPU configuration with TP communication
2MLR-CPUH/F Redundant CPU configuration with FO communication
2MLR-M02P Main CPU base for a two-module installation
2MLR-M06P Main CPU base for a six-module installation
2MLR-DBDH Provides the TP/FO hybrid interface for redundant I/O expansion
2MLR-E12H Redundant expansion base with 12 slots
2MLR-DBDT Redundant expansion driver using TP communication
2MLR-DBDF Redundant expansion driver using FO communication
MasterLogic I/O Modules Acquire field inputs and control connected output devices
Field Instruments Supply process measurements and equipment status signals
Industrial Actuators Execute output commands from the PLC system

The driver, expansion base, and communication cabling must be selected as a compatible arrangement. The presence of both TP and FO interfaces does not mean that every cable type or network topology can be used without configuration checks.


Industrial Applications

The 2MLR-DBDH is suitable for MasterLogic-200R installations where redundant I/O communication requires a hybrid transmission arrangement.

Industrial Application Typical Use
Oil and Gas Processing Connecting distributed I/O cabinets through mixed communication media
Petrochemical Plants Supporting redundant expansion networks across different process areas
Chemical Processing Connecting remote I/O assemblies in electrically demanding environments
Power Generation Supporting distributed control cabinet communication
Refinery Automation Integrating local and remote I/O connections
Water Treatment Facilities Connecting process instrumentation through distributed I/O bases
Compressor Stations Linking remote monitoring and control equipment
Industrial Manufacturing Expanding PLC I/O networks across production areas
Continuous Process Plants Supporting redundant communication between controller and remote I/O
Large Industrial Facilities Accommodating different cable-routing and transmission requirements

Installation and Maintenance

  1. Verify the Complete Model Number: Confirm that the replacement is 2MLR-DBDH and not the TP-only or FO-only redundant expansion driver.
  2. Check the Communication Configuration: Review the existing network design and confirm that the installation requires a TP/FO hybrid driver.
  3. Inspect the Expansion Base: Verify that the module is installed in a compatible 2MLR-E12H redundant expansion base.
  4. Review the Network Diagram: Identify the primary and secondary I/O communication paths and determine where TP and FO connections are used.
  5. Isolate the Equipment: Follow the approved shutdown and electrical isolation procedures before removing or installing the module.
  6. Inspect the Driver Connector: Check the module interface and expansion-base connector for contamination, loose connections, or mechanical damage.
  7. Check TP Cabling: Inspect twisted-pair cables for damaged insulation, loose terminations, and incorrect cable routing.
  8. Inspect Fiber-Optic Connections: Check optical cables and connectors for contamination, damaged jackets, and excessive bending.
  9. Verify Media Assignment: Confirm that the TP and FO connections are connected to their intended ports according to the system wiring documentation.
  10. Check Redundant Links: Verify that both I/O communication paths are connected and configured according to the original architecture.
  11. Perform Communication Testing: Confirm that the CPU can exchange data with the remote expansion base and verify the operation of the configured redundant links.
  12. Document Maintenance Results: Record the driver model, expansion-base position, cable connections, and functional test results.

When troubleshooting communication problems, inspect the TP and FO connections separately. A fault affecting one transmission medium may not have the same symptoms as a problem in the other communication path.


Compatible System Components

Component Function
Honeywell 2MLR-CPUH/T Redundant CPU configuration with TP communication
Honeywell 2MLR-CPUH/F Redundant CPU configuration with FO communication
Honeywell 2MLR-E12H Redundant expansion base with 12 slots
Honeywell 2MLR-DBDT Redundant expansion driver using TP communication
Honeywell 2MLR-DBDF Redundant expansion driver using FO communication
Honeywell 2MLR-DBST Standard expansion driver using TP communication
Honeywell 2MLR-DBSF Standard expansion driver using FO communication
Honeywell 2MLR-DBSH Standard expansion driver using TP/FO hybrid communication
Honeywell 2MLC-F201 Multimode fiber-optic synchronization cable with LC connectors
MasterLogic-200 I/O Modules Handle distributed digital and analog field signals

Recommended Related Models

Model / Product Family Product Type Typical Application
Honeywell 2MLR-DBDT Redundant Expansion Driver, TP Redundant expansion communication through twisted-pair cabling
Honeywell 2MLR-DBDF Redundant Expansion Driver, FO Redundant expansion communication through fiber-optic cabling
Honeywell 2MLR-DBSH Expansion Driver, TP/FO Standard hybrid expansion communication
Honeywell 2MLR-DBST Expansion Driver, TP Standard twisted-pair expansion communication
Honeywell 2MLR-DBSF Expansion Driver, FO Standard fiber-optic expansion communication
Honeywell 2MLR-E12H Redundant Expansion Base, 12 Slot Distributed I/O expansion with dual-link redundancy

Key Advantages

  • Hybrid TP/FO communication configuration.
  • Supports the MasterLogic-200R redundant expansion architecture.
  • Accommodates mixed copper and fiber-optic network arrangements.
  • Suitable for distributed I/O communication.
  • Compatible with the 2MLR-E12H redundant expansion base.
  • Provides an alternative to dedicated TP and FO redundant drivers.
  • Supports industrial automation installations with different transmission requirements.
  • Dedicated part number for maintenance and replacement identification.

Technical FAQs

1. What does TP/FO mean on the Honeywell 2MLR-DBDH?

TP/FO stands for Twisted Pair/Fiber Optic. It identifies the hybrid communication configuration, which supports both copper-based twisted-pair and optical-fiber communication within the specified MasterLogic-200R network arrangement.

2. What is the difference between the 2MLR-DBDH and the 2MLR-DBDF?

The 2MLR-DBDH is the hybrid TP/FO redundant expansion driver, whereas the 2MLR-DBDF is the fiber-optic redundant expansion driver. The DBDH is selected when the system requires a hybrid communication arrangement, while the DBDF is used for the specified FO configuration.

3. Which expansion base is used with the 2MLR-DBDH?

The 2MLR-DBDH is associated with the 2MLR-E12H redundant expansion base. This 12-slot base supports the dual I/O link redundancy arrangement and provides the designated position for the redundant expansion driver.

4. Can the 2MLR-DBDH replace the 2MLR-DBDT without changing the wiring?

Not necessarily. Although both are redundant expansion drivers, the DBDT uses TP communication while the DBDH supports a hybrid TP/FO arrangement. The existing network topology, connector assignments, and communication configuration must be checked before replacement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501