Product Overview The Schneider Electric MT63H1 Circuit Breaker is an industrial low-voltage circuit protection device associated with the Masterpact air circuit breaker product family. Designed for high……
Schneider MT63H1 Circuit Breaker
  • Schneider
  • MT63H1
  • Circuit Breaker
  • France
  • 819 x 311 x 290 mm
  • 120 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Schneider MT63H1 Circuit Breaker

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider MT63H1 Circuit Breaker

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider MT63H1 Circuit Breaker

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider MT63H1 Circuit Breaker

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider Electric MT63H1 Circuit Breaker is an industrial low-voltage circuit protection device associated with the Masterpact air circuit breaker product family. Designed for high-capacity electrical distribution systems, this type of circuit breaker is used to protect electrical installations against abnormal operating conditions, including overloads and short circuits.

Large air circuit breakers are commonly installed in main distribution boards, power control centers, industrial switchgear, and other high-current electrical systems. They provide a means of switching and isolating electrical circuits while supporting coordinated protection between the incoming supply and downstream distribution equipment.

The MT63H1 designation is associated with a high-current Masterpact configuration. Available product references identify the M63H1 variant as a three-pole, 6300 A Masterpact circuit breaker with a 600 V listing and solid-state electronic protection. However, the exact configuration of an individual MT63H1 unit must be confirmed from its nameplate and installed accessories. The MT63H1 designation should not be confused with the newer Masterpact MTZ3 63H1 product family.

In industrial installations, a circuit breaker of this class is generally used at a major power distribution point where high fault levels and substantial load currents must be managed. Its protection settings and installation arrangement must be coordinated with the electrical system design.

The supplied product dimensions are 819 × 311 × 290 mm, with a listed weight of 120 kg. These values are retained as the provided listing information and should be verified against the actual breaker assembly, including any cradle, accessories, and packaging.

Technical Specifications

Parameter Specification
Brand Schneider Electric
Product Family Masterpact
Model MT63H1
Product Type Circuit Breaker
Breaker Category Air Circuit Breaker / High-Capacity Circuit Breaker
Associated Variant Reference M63H1
Number of Poles 3P, subject to nameplate verification
Current Rating 6300 A for the associated M63H1 variant
Voltage Listing 600 V for the associated M63H1 reference
Protection Type Solid-state electronic protection for the associated M63H1 reference
Application Industrial power distribution protection
Dimensions Provided 819 × 311 × 290 mm
Weight Provided 120 kg
Installation Verify fixed or drawout configuration from the actual unit
Trip Unit Verify installed trip-unit model and settings
Product Identification Confirm full catalog designation and nameplate details

Important: The table distinguishes the supplied listing information from specifications associated with the M63H1 reference. Confirm the exact MT63H1 catalog designation, voltage rating, pole configuration, trip unit, and interrupting capacity before technical selection or replacement.

Function and Working Principle

The MT63H1 circuit breaker is intended to provide switching and protective functions in high-current electrical distribution systems. Its operation involves monitoring circuit conditions and interrupting current when a detected fault exceeds the configured protection limits.

1. Overload Protection

An overload occurs when a circuit carries more current than its intended operating capacity for a sustained period. If not interrupted, excessive current can cause conductor overheating, insulation deterioration, and damage to connected equipment.

Electronic protection systems can evaluate current levels and apply configured time delays before initiating a trip. This allows the protection system to distinguish between temporary operating conditions and sustained overloads.

The actual overload protection characteristics depend on the installed trip unit and its settings.

2. Short-Circuit Protection

A short circuit can produce a rapid increase in current, creating high thermal and electromagnetic stress on electrical equipment.

The circuit breaker’s protection system detects fault conditions and initiates the opening mechanism to interrupt the affected circuit. Its ability to interrupt a fault safely depends on the rated breaking capacity at the actual system voltage and the available fault current.

Engineers must confirm the applicable Icu, Ics, and short-time withstand ratings from the exact product documentation. These values must not be assumed from the model-family name alone.

3. Switching and Isolation

Large industrial circuit breakers also provide switching and isolation functions. They allow authorized personnel to disconnect electrical distribution sections for maintenance, inspection, or system reconfiguration.

Isolation procedures must follow the applicable electrical safety standards. Opening a breaker does not automatically establish a safe working condition; personnel must verify isolation, discharge stored energy where applicable, and follow lockout/tagout procedures.

4. Electronic Protection Coordination

Electronic trip units can provide configurable protection functions, depending on the installed version. These may include long-time, short-time, instantaneous, and ground-fault protection.

The settings should be coordinated with upstream and downstream protective devices. Proper coordination helps ensure that a fault is cleared by the appropriate breaker while limiting unnecessary interruption to other parts of the electrical installation.

Role in Industrial Power Distribution Systems

The MT63H1 is intended for high-capacity power distribution applications where circuit protection and controlled switching are essential.

Main Incoming Protection

A high-current air circuit breaker may be installed at the incoming section of a main distribution board. It provides a protective switching point between the incoming electrical supply and the facility’s internal distribution network.

Its rating and trip settings must be matched to the transformer, busbar system, conductor capacity, and available short-circuit current.

Busbar Section Protection

Industrial switchgear often uses busbars to distribute power to multiple outgoing feeders. A main or sectionalizing breaker can help isolate a busbar section when maintenance or a fault condition requires disconnection.

The breaker’s rated current, short-time withstand capability, and protection coordination are important when designing this arrangement.

Generator and Transformer Distribution

High-capacity circuit breakers may be used in generator or transformer distribution systems. Their function is to provide switching and fault protection while supporting coordination with generator controls, transformer protection, and downstream feeders.

The exact breaker application depends on the electrical system’s grounding arrangement, fault characteristics, and protection study.

Power Control Centers

In large industrial facilities, circuit breakers are central components of power control centers. They help protect production equipment, distribution feeders, and major electrical loads.

A suitable breaker must be selected according to the system voltage, rated current, fault level, operating duty, and installation configuration.

Industrial Applications

1. Manufacturing Plants

Large manufacturing facilities require stable electrical distribution for production lines, motors, process equipment, and auxiliary systems. High-capacity circuit breakers can protect main distribution sections and support controlled isolation during maintenance.

2. Power Generation Facilities

Power generation installations use circuit breakers to connect and disconnect electrical distribution sections and protect equipment against abnormal current conditions.

Breaker selection must account for generator characteristics, system fault levels, and the coordination requirements of the protection scheme.

3. Data Centers

Data centers depend on reliable electrical distribution for servers, cooling systems, UPS equipment, and power distribution units. Main circuit breakers can provide protection and switching at major distribution points.

The breaker must be coordinated with upstream transformers, backup power sources, and downstream protective devices to support the facility’s electrical reliability strategy.

4. Petrochemical and Process Industries

Petrochemical plants and continuous-process facilities use large electrical distribution systems to supply pumps, compressors, motors, and process equipment.

Circuit breakers in these installations must be selected with attention to fault current, environmental conditions, maintenance access, and the plant’s electrical protection philosophy.

5. Infrastructure and Utility Distribution

Large commercial buildings, infrastructure facilities, and utility-related installations may use high-capacity air circuit breakers in main switchboards and distribution assemblies.

Their switching and protective functions help manage the electrical supply to multiple distribution branches.

Installation and System Integration

Correct installation is essential for the safe and reliable operation of a high-current circuit breaker.

1. Verify the Electrical System Rating

Before installation, confirm the system’s nominal voltage, rated frequency, maximum load current, and prospective short-circuit current.

The breaker’s rated current must be appropriate for the busbar and conductor capacity. Its breaking capacity must be sufficient for the fault level at the installation point.

Do not use the 6300 A figure associated with the M63H1 reference as the sole basis for selecting an MT63H1 unit. Verify the actual nameplate and technical documentation.

2. Check Mounting Configuration

Confirm whether the unit is fixed-mounted or drawout-mounted. These arrangements have different installation requirements, mechanical interfaces, and maintenance procedures.

For drawout assemblies, inspect the cradle, guide rails, primary contacts, secondary connections, and mechanical interlocks. Ensure that the breaker can move between its permitted positions without obstruction.

3. Inspect Main Electrical Connections

Inspect the main terminals, busbar connections, contact surfaces, and fastening hardware. Follow the manufacturer’s specified tightening torques and connection procedures.

Poor electrical connections can lead to localized heating, voltage drop, and premature component deterioration.

4. Configure the Trip Unit

Identify the installed trip unit and confirm its supported protection functions. Set long-time, short-time, instantaneous, and ground-fault parameters as required by the approved protection study.

Protection settings should be reviewed by qualified electrical engineers. Incorrect settings can compromise equipment protection or cause unnecessary power interruptions.

5. Verify Auxiliary and Control Circuits

Large circuit breakers may use auxiliary contacts, shunt trips, undervoltage releases, motor-charging mechanisms, and other accessories.

Confirm the installed accessories and their control voltage before connecting them to the switchgear control system. Do not assume that accessories supplied with another Masterpact variant are automatically compatible.

6. Perform Commissioning Tests

Before energizing the installation, inspect the mechanical operation, electrical connections, interlocks, auxiliary circuits, and protection settings.

Carry out the appropriate insulation, contact resistance, trip-unit, and functional tests according to the manufacturer’s procedures and the site’s commissioning requirements.

Testing should be performed by qualified personnel using suitable equipment and approved safety procedures.

Compatible System Components

The MT63H1 is normally integrated into a larger electrical distribution assembly. The following components may be used in a suitable system, subject to exact model and configuration compatibility.

Component Function Compatibility Considerations
Main switchgear cabinet Houses the circuit breaker and distribution equipment Confirm dimensions, mounting arrangement, and required clearances
Busbar system Distributes high-current electrical power Verify current rating, short-time withstand rating, and connection geometry
Electronic trip unit Provides configurable protective functions Confirm exact breaker compatibility and protection settings
Auxiliary contacts Provide breaker status signals Check contact configuration and control-circuit ratings
Shunt trip accessory Enables remote electrical tripping Verify accessory type and control voltage
Undervoltage release Trips or prevents closing under specified voltage conditions Confirm the correct accessory and supply requirements
Motor-charging mechanism Charges the breaker operating mechanism Verify voltage and mechanical compatibility
PLC or electrical monitoring system Monitors breaker status and coordinates operations Confirm auxiliary contacts and any required communication interface
Current transformers Supply current measurement signals to protection or monitoring equipment Verify ratio, accuracy, wiring, and protection requirements

These components are examples of equipment used in industrial switchgear. They are not necessarily included with the MT63H1 breaker.

Alternative Models and Replacement Considerations

The MT63H1 designation must be checked carefully before selecting an alternative. A breaker with a similar current rating or a similar Masterpact name may belong to a different product generation.

Alternative or Related Product Replacement Considerations
Masterpact M63H1 Closely associated legacy designation; verify the exact catalog reference and installed configuration
Masterpact MTZ3 63H1 A different product generation; not automatically interchangeable with MT63H1
Other Masterpact high-current models Compare current rating, voltage, breaking capacity, pole configuration, and mounting arrangement
Current-generation Schneider Electric air circuit breakers May be considered for a modernization project after a complete engineering review

Before replacing the breaker, compare:

  • Complete catalog number and nameplate information.
  • Rated operational voltage and frequency.
  • Rated current and temperature conditions.
  • Number of poles and neutral arrangement.
  • Rated ultimate and service breaking capacities.
  • Short-time withstand current and duration.
  • Installed trip unit and protection functions.
  • Fixed or drawout mounting arrangement.
  • Main terminal and busbar connection dimensions.
  • Auxiliary contacts and electrical accessories.
  • Control voltage and operating mechanism.
  • Panel dimensions and required installation clearances.

A replacement breaker may require changes to the switchgear, busbars, control wiring, protection coordination, or commissioning procedures. A matching current rating alone does not establish compatibility.

Key Advantages

High-Current Distribution Capability

The associated M63H1 reference is rated for 6300 A, making it relevant to high-capacity industrial distribution applications. Confirm the actual MT63H1 nameplate before relying on this rating.

Electronic Protection

The associated product reference identifies solid-state electronic protection. The actual protective functions and settings depend on the installed trip unit.

Industrial Switching Function

The circuit breaker provides a switching point for controlling and isolating major electrical distribution sections.

Integration into Switchgear Assemblies

Masterpact circuit breakers are designed for use in engineered electrical distribution assemblies. Correct mounting and accessory selection are essential for safe integration.

Maintenance and Replacement Relevance

Legacy Masterpact equipment may remain in service in industrial facilities. Accurate identification supports maintenance planning and spare-parts procurement.

Technical FAQs

1. What is the Schneider Electric MT63H1?

MT63H1 is a circuit breaker designation associated with the Schneider Electric / Merlin Gerin Masterpact high-capacity breaker family. The exact product generation and configuration should be confirmed from the nameplate.

2. What is the rated current?

The associated M63H1 reference is listed at 6300 A. Confirm the exact MT63H1 nameplate and technical documentation before using this figure for electrical design.

3. Is MT63H1 the same as MTZ3 63H1?

No. These designations refer to different product generations. MTZ3 63H1 is a Masterpact MTZ3 model and should not be treated as a direct substitute for MT63H1 without a detailed compatibility assessment.

4. What is the function of an air circuit breaker?

An air circuit breaker provides switching and protective functions in electrical distribution systems. It can interrupt abnormal current conditions when the installed protection system detects a fault that meets its trip criteria.

5. What protection functions are available?

Protection functions depend on the installed trip unit. Common functions in electronic breaker protection systems include long-time, short-time, instantaneous, and ground-fault protection. Verify the actual trip-unit model before specifying these functions.

6. Can the MT63H1 be installed in an existing Masterpact switchgear cabinet?

It may be possible if the breaker, cradle, mounting dimensions, terminal arrangement, and accessories are compatible. The cabinet and breaker must be checked against the relevant manufacturer drawings.

7. What should be checked before purchasing a used unit?

Check the complete nameplate, breaker condition, operating mechanism, contact condition, trip unit, accessories, and available test records. For critical power distribution systems, request appropriate inspection and functional testing.

8. Is the listed weight of 120 kg the shipping weight?

The supplied 120 kg is retained as the product listing weight. Confirm whether it represents the breaker alone, a complete drawout assembly, or a packaged shipment before arranging transport.

9. Can a modern Masterpact MTZ3 replace this breaker?

Not automatically. A replacement project must evaluate electrical ratings, fault performance, mounting dimensions, busbar connections, trip-unit functionality, accessories, and switchgear compatibility.

10. Why is the exact catalog number important?

Different Masterpact generations and configurations can have different dimensions, protection functions, electrical ratings, and accessories. Correct identification helps prevent an unsuitable replacement from being installed in a critical distribution system.

Procurement and Maintenance Recommendations

When sourcing the Schneider Electric MT63H1, begin by checking the complete nameplate and identifying the exact Masterpact generation. The distinction between MT63H1, M63H1, and MTZ3 63H1 is particularly important because similar designations do not guarantee identical technical characteristics.

For used or surplus equipment, request clear photographs of the front panel, nameplate, trip unit, terminals, operating mechanism, and any supplied cradle or accessories. Ask for inspection or test records where available, especially if the breaker is intended for a critical power distribution system.

Confirm whether the listed dimensions of 819 × 311 × 290 mm and weight of 120 kg apply to the standalone breaker or a complete assembly. Shipping arrangements should account for the actual packaged dimensions, lifting points, and handling requirements.

During maintenance, inspect the main contacts, terminal connections, operating mechanism, auxiliary circuits, and trip-unit settings according to the manufacturer’s maintenance schedule. Record test results and parameter changes to support future maintenance and replacement activities.

For replacement planning, conduct a complete electrical and mechanical compatibility assessment. Review the fault-current study, protection coordination, busbar arrangement, control wiring, and switchgear construction before selecting another Masterpact model.

Conclusion

The Schneider Electric MT63H1 Circuit Breaker is associated with the Masterpact family of high-capacity industrial circuit breakers. Such equipment is used in main switchboards, power control centers, and other electrical distribution systems where reliable switching and fault protection are essential.

The associated M63H1 reference is listed as a 6300 A, three-pole breaker, but the exact electrical ratings and configuration of an MT63H1 unit must be verified from its nameplate and manufacturer documentation. Careful model identification, trip-unit inspection, and compatibility checks are essential when purchasing, maintaining, or replacing this equipment.