Product Overview The Foxboro P0926KL is an I/A Series power supply output cable used to connect compatible Foxboro 200 Series power supplies to modular baseplates. It forms part of the subsystem’s……
Foxboro P0926KL I/A Series Power Supply Output Cable
  • Foxboro
  • P0926KL
  • Power Supply Output Cable
  • USA
  • 0.9 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Foxboro P0926KL I/A Series Power Supply Output Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro P0926KL I/A Series Power Supply Output Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro P0926KL I/A Series Power Supply Output Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro P0926KL I/A Series Power Supply Output Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro P0926KL is an I/A Series power supply output cable used to connect compatible Foxboro 200 Series power supplies to modular baseplates. It forms part of the subsystem’s power-distribution arrangement, carrying the supply output to the baseplate where fieldbus modules and related control hardware receive their operating power.

With a cable length of 0.9 meters, the P0926KL suits cabinet layouts where the power supply and receiving baseplate are positioned within a short distance of one another. Its role differs from a DC input terminal block cable, which connects incoming power to the power supply itself. The P0926KL instead serves the downstream connection between the supply and the baseplate.

This cable is associated with the older P0926KL part designation. The corresponding newer cable designation is RH926KL, also specified at 0.9 meters for compatible modular baseplates. When maintaining an existing installation, the baseplate family and connector arrangement should be checked before choosing a replacement.


Technical Specifications

Parameter Specification
Manufacturer Foxboro
Model P0926KL
Product Series I/A Series
Product Type Power Supply Output Cable
Cable Function Power supply to modular baseplate connection
Cable Length 0.9 meters
Cable Construction Shielded power cable
Conductor Size 16 AWG
System Application Foxboro 200 Series control subsystem
Compatible Equipment Compatible 200 Series power supplies and modular baseplates
Newer Cable Designation RH926KL
Shipping Weight 3 kg

Product Features

  • Dedicated output-power connection: Connects a compatible power supply to its designated modular baseplate.
  • 0.9-meter cable length: Supports short-distance power connections inside control cabinets.
  • Shielded cable construction: Uses a shielded cable arrangement for the intended industrial power-distribution application.
  • 16 AWG conductors: Matches the conductor specification listed for this cable family.
  • 200 Series subsystem integration: Supports power connections between compatible Foxboro power supplies and modular baseplates.
  • Defined cable identification: The P0926KL designation distinguishes this cable from input-terminal-block cables and other baseplate cable lengths.
  • Replacement planning: The newer RH926KL designation provides a reference when reviewing cable replacement requirements.
  • Organized cabinet wiring: A dedicated cable assembly helps maintain an orderly power connection between system components.

Working Principle

The P0926KL establishes an electrical path from the output connector of a compatible Foxboro power supply to the corresponding connector on a modular baseplate. Once connected correctly, the cable carries the supply’s output power to the baseplate power-distribution interface.

The cable does not convert or regulate voltage. Those functions are handled by the power supply, while the baseplate distributes power to the installed control-system hardware according to its design. The cable’s conductor arrangement, connectors and length must therefore match the intended system configuration.

During commissioning or maintenance, technicians should verify the cable part number, connector seating and routing before restoring power. The connected baseplate and installed modules must remain within the power supply’s specified capacity. The cable should not be treated as interchangeable with a DC input cable or an alarm-status relay output cable.


Role in a Foxboro I/A Series Power Distribution Architecture

The P0926KL connects the power supply output to a compatible modular baseplate in a Foxboro 200 Series control subsystem. The power supply generates the required DC output, the cable transfers that output, and the baseplate distributes power to the associated modules.

System Component Function Relationship to the P0926KL
Foxboro P0926KL Transfers power-supply output to a baseplate Provides the cable connection between the two components
Foxboro FPS400-24 Power Supply Supplies 24 V DC output power Feeds the baseplate through the designated cable
Modular Baseplate Provides mounting and electrical interfaces for modules Receives power through the output cable
Fieldbus Modules (FBMs) Interface field signals with the control system Receive operating power through the configured subsystem
Field Control Processor (FCP), Where Applicable Executes control and communication functions Operates within a compatible system power architecture
Redundant Power Supply, Where Configured Provides an alternative power source May use a separate compatible cable and connection
Control Cabinet Houses power and control hardware Supports cable routing and component mounting
Cabinet Power Distribution Organizes incoming and distributed power connections Separates supply input wiring from baseplate output wiring

Industrial Applications

Application Power Connection Requirement Role of the P0926KL
Foxboro I/A Series Control Cabinets Power connection between a supply and modular baseplate Transfers output power to the baseplate
Process Automation Systems Distributed power for control-system modules Supports the configured baseplate power path
Oil and Gas Facilities Organized power wiring within process-control cabinets Connects compatible power and baseplate hardware
Chemical Processing Plants Power distribution for process-control equipment Forms part of the subsystem’s output-power connection
Power Generation Control DC power delivery to compatible control-system baseplates Connects the supply output to the receiving baseplate
Water and Wastewater Automation Cabinet-based control-system power distribution Supports the designated baseplate connection
Control-System Expansion Addition of compatible baseplates within a subsystem Provides a specified cable length for the planned layout
Maintenance and Replacement Replacement of a damaged or incorrectly identified output cable Restores the power connection when the P0926KL is the required part

Installation and Maintenance

  1. Verify the cable part number: Confirm that P0926KL is the specified output cable for the intended power supply and baseplate configuration.
  2. Identify the baseplate family: Check whether the receiving baseplate belongs to the compatible modular baseplate family before installation.
  3. Isolate the power supply: Follow site lockout and electrical isolation procedures before disconnecting or replacing the cable.
  4. Inspect both connectors: Check for damaged housings, bent contacts, contamination or other conditions that could prevent proper mating.
  5. Confirm connector orientation: Align the connectors with their intended interfaces and avoid forcing a connection that does not seat correctly.
  6. Check the cable routing: Ensure the cable can reach both connection points without excessive tension or strain on the connectors.
  7. Avoid sharp bends and crushing: Route the cable away from cabinet edges, moving equipment and other potential sources of mechanical damage.
  8. Keep power wiring organized: Separate the output cable from unrelated wiring where required by the cabinet’s wiring practices and equipment instructions.
  9. Secure the connections: Confirm that each connector is fully seated and any applicable retaining mechanism is engaged.
  10. Check power-supply loading: Verify that the connected baseplate and installed modules remain within the power supply’s specified output capacity.
  11. Inspect before energizing: Check the cable jacket, connector seating and routing before restoring power to the subsystem.
  12. Record the installed cable variant: Document the part number and any replacement or connection issues to help prevent incorrect substitutions during future maintenance.

Related Components

Component Function Relationship to the P0926KL
Foxboro FPS400-24 Power Supply Supplies DC output power to the subsystem Provides the output connected to the baseplate through the cable
Foxboro Modular Baseplate Houses and electrically connects compatible modules Receives power from the cable
Foxboro RH926KL Newer baseplate power supply cable designation Supersedes P0926KL for the specified 0.9-meter cable configuration
Foxboro P0926KK Older baseplate power supply cable, 0.4-meter variant Provides a shorter cable option for compatible baseplates
Foxboro RH926KK Newer 0.4-meter baseplate power supply cable Related shorter-length cable variant
Foxboro P0926KM Older baseplate power supply cable, 1.2-meter variant Provides a longer cable option for compatible baseplates
Foxboro RH926KM Newer 1.2-meter baseplate power supply cable Related longer-length cable variant
Foxboro RH923NG Power-distribution Y-cable Supports additional power connections in compatible FPS400 installations
Foxboro P0923DG / RH923DG DC input terminal block cable Connects the input terminal block to the power supply rather than the supply to a baseplate

Recommended Related Models

Model Product Type Relationship Selection Consideration
Foxboro P0926KL I/A Series Power Supply Output Cable Main product 0.9-meter output cable for compatible modular baseplates
Foxboro RH926KL I/A Series Power Supply Output Cable Newer designation Listed as the successor to P0926KL at the same cable length
Foxboro P0926KK I/A Series Power Supply Output Cable Shorter cable variant 0.4-meter cable for compatible modular baseplates
Foxboro RH926KK I/A Series Power Supply Output Cable Newer shorter-length variant Check connector and baseplate compatibility
Foxboro P0926KM I/A Series Power Supply Output Cable Longer cable variant 1.2-meter cable for compatible modular baseplates
Foxboro RH926KM I/A Series Power Supply Output Cable Newer longer-length variant Check the required cable routing distance
Foxboro RH923NG I/A Series Power Distribution Y-Cable Related distribution component Used to provide additional physical connections in compatible FPS400 installations

Key Advantages

  • Provides a defined 0.9-meter output-power connection for compatible Foxboro modular baseplates.
  • Uses shielded 16 AWG cable construction.
  • Supports organized power distribution within 200 Series control cabinets.
  • Has a corresponding newer designation, RH926KL, for replacement planning.
  • Keeps baseplate output wiring distinct from power-supply input and alarm-status wiring.

Technical FAQs

What does the P0926KL connect in a Foxboro control system?

The P0926KL connects a compatible power supply’s output to a modular baseplate. The baseplate then distributes power to the installed control-system hardware according to the subsystem configuration.

How does P0926KL differ from P0923DG?

P0926KL is a power supply output cable used between a power supply and a modular baseplate. P0923DG is a DC input terminal block cable used between the input terminal block and the power supply. They serve different connection points and should not be substituted for one another.

Is RH926KL the newer designation for P0926KL?

Yes. The newer cable designation RH926KL supersedes P0926KL for the listed 0.9-meter baseplate power connection. Before replacement, confirm that the installed baseplate family and connector arrangement match the intended cable configuration.

What should be checked if a baseplate loses power after cable replacement?

Check that the cable is the correct output-power variant, both connectors are fully seated, and the power supply is operating normally. Also verify the baseplate connection and subsystem loading. Isolate power before inspecting or reconnecting the cable.