• Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply
  • Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply
  • Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply
  • Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply
Product Overview The Emerson VE5008 KJ1501X1-BC2 12P2186X042 is identified as a DeltaV M-Series system power supply. In a distributed control system, the power supply forms part of the electrical infras……
Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply
  • Emerson
  • VE5008 KJ1501X1-BC2 12P2186X042
  • System Power Supply
  • USA
  • 145 × 120 × 60 mm
  • 0.68 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson VE5008 KJ1501X1-BC2 12P2186X042 DeltaV M-Series System Power Supply

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson VE5008 KJ1501X1-BC2 12P2186X042 is identified as a DeltaV M-Series system power supply. In a distributed control system, the power supply forms part of the electrical infrastructure that keeps compatible controller and I/O hardware operating within its specified power requirements.

The KJ1501X1-BC2 and 12P2186X042 identifiers are important when selecting a replacement or maintaining an installed system. Product-family names alone do not establish electrical interchangeability, so the full part number should be considered alongside the carrier arrangement, input source, and power requirements of the connected hardware.

In a process-control cabinet, system power supplies work alongside controllers, I/O modules, carriers, and power distribution components. Their role is to supply electrical power; process measurements and control decisions are handled by the controller and I/O modules.

For installation or replacement, verify the complete model identification and the intended system configuration before connecting the unit.


Technical Specifications

Parameter Specification
Manufacturer Emerson
Model VE5008
Part Number KJ1501X1-BC2
Alternate Part Number 12P2186X042
Product Family DeltaV M-Series
Product Type System Power Supply
Dimensions 145 × 120 × 60 mm
Weight 0.68 kg

Product Features

  • Dual DC/DC power conversion: Accepts compatible DC input power and generates the regulated voltage rails required by the DeltaV M-Series control hardware.
  • Multiple output rails: Supplies 12 VDC, 5.1 VDC, and 3.4 VDC outputs for compatible system components.
  • Carrier-mounted installation: Fits the appropriate slot on a compatible two-wide power/controller carrier.
  • Output status monitoring: Uses alarm relay contacts to indicate whether the monitored 3.3 V and 5 V logic outputs remain within their specified tolerance.
  • Internal input protection: Incorporates non-replaceable input fuses.
  • System power integration: Supplies the control-system electronics through the M-Series power architecture.
  • Temperature-dependent output capacity: Output-current limits vary with input voltage and operating temperature, which must be considered during load planning.

Working Principle

The KJ1501X1-BC2 converts DC input power into regulated outputs for compatible DeltaV M-Series control hardware.

DC Input → KJ1501X1-BC2 → Regulated DC Rails → Controller and I/O Hardware

The supply supports different DC input arrangements, with output capacity depending on the selected input voltage and operating conditions. The 12 VDC rail powers compatible system loads, while the 5.1 VDC and 3.4 VDC rails serve the associated logic electronics.

During operation, the supply’s alarm relay monitors the specified logic output conditions. When the monitored outputs remain within their defined tolerance, the relay contacts indicate the normal state. A change in relay state can therefore help identify a power fault, although additional measurements may be needed to determine its cause.

When diagnosing an issue, measure the input voltage and examine the output rails, carrier connections, and connected load. The input source must remain within its specified range, and the output current must stay within the limit for the actual input voltage and ambient temperature.


Role in a DeltaV M-Series Control System Architecture

The KJ1501X1-BC2 supplies power to compatible control hardware through the M-Series power/controller carrier. It performs the electrical power-conversion function, while the controller executes control strategies and the I/O modules handle communication with process instrumentation.

DC Power Source → KJ1501X1-BC2 → Power/Controller Carrier → Controller and I/O System

System Element Function
DC Input Source Provides the required DC input power
KJ1501X1-BC2 Converts input power into regulated system voltage rails
Power/Controller Carrier Provides mounting and electrical interconnection
DeltaV Controller Executes control logic and coordinates system operation
Analog Input Modules Acquire continuous process measurements
Analog Output Modules Deliver analog control signals to compatible devices
Discrete I/O Modules Handle binary field status and control signals
Alarm Relay Circuit Provides an indication of monitored logic-output status
Field Instruments Measure process variables and report equipment status
Control Cabinet Houses the power supply, controller, I/O hardware, and associated wiring

The actual configuration depends on the installed carrier, controller, I/O modules, input source, and power demand. The supply should be matched to the intended system arrangement rather than treated as a universal replacement for every DeltaV power-supply variant.


Industrial Applications

Application Typical Use
Process Automation Supplying system power to compatible DeltaV control hardware
Oil and Gas Powering control-system electronics in process automation cabinets
Chemical Processing Supporting controller and I/O operation in distributed control installations
Water Treatment Providing system power for compatible monitoring and control equipment
Power Generation Supplying control hardware used in plant automation
Pharmaceutical Manufacturing Supporting control-system operation in automated process installations
Food and Beverage Powering compatible control-system hardware for production processes
Industrial Manufacturing Providing regulated DC rails for controller and I/O assemblies

Installation and Maintenance

  1. Confirm the complete KJ1501X1-BC2 and 12P2186X042 identifiers before installation or replacement.
  2. Verify that the intended system uses a compatible DeltaV M-Series power/controller carrier.
  3. Check the available DC input source and confirm that its voltage matches the selected input arrangement.
  4. Isolate the input power before connecting or disconnecting the supply.
  5. Inspect the carrier and electrical connectors for damage, contamination, or loose connections.
  6. Install the unit in the correct carrier position according to the system configuration.
  7. Verify the input wiring and polarity before energizing the supply.
  8. Calculate the load on each output rail, accounting for the input voltage and operating temperature.
  9. Restore power according to the system commissioning procedure and check the monitored output status.
  10. If a power alarm occurs, measure the input voltage and check the output rails and carrier connections.
  11. Inspect the connected hardware for excessive load or a short circuit before replacing the supply.
  12. Record the installed part number and carrier position to simplify future maintenance and troubleshooting.

The supply’s input power must be removed before connecting or disconnecting its input wiring. For replacement work, verify the complete electrical configuration rather than relying solely on the shared DeltaV product-family designation.


Related Components

Component Function
DeltaV M-Series Power/Controller Carrier Provides mounting and interconnection for compatible system hardware
DeltaV M-Series Controller Executes control logic and coordinates process I/O
DeltaV Analog Input Modules Acquire continuous process measurements
DeltaV Analog Output Modules Send analog control signals to field equipment
DeltaV Discrete Input Modules Acquire binary field status signals
DeltaV Discrete Output Modules Control compatible discrete field devices
DC Input Power Source Supplies the DC input required by the KJ1501X1-BC2
Power Alarm Circuit Uses the supply’s relay contacts to monitor output status
Protective-Earth Connection Provides the grounding arrangement required by the installation
Control Cabinet Wiring Connects the supply, carrier, controller, and I/O components

Recommended Related Models

Model / Product Family Product Type Typical Application
Emerson VE5008 KJ1501X1-BC2 DeltaV M-Series DC/DC System Power Supply Regulated power for compatible M-Series hardware
Emerson KJ1501X1-BC1 DeltaV Dual DC/DC System Power Supply System power for a compatible configuration
Emerson KJ1501X1-BC3 DeltaV Dual DC/DC System Power Supply DC system power with model-specific output ratings
Emerson VE5001 KJ1501X1-BA Series DeltaV AC/DC System Power Supply Powering compatible system hardware from an AC source
DeltaV M-Series Power/Controller Carrier System carrier Mounting and interconnection for compatible hardware
DeltaV M-Series Controller Controller Executing control strategies and coordinating I/O

Key Advantages

  • Provides regulated DC power for compatible DeltaV M-Series hardware.
  • Supports multiple output rails for system electronics.
  • Accommodates specified DC input arrangements.
  • Includes input protection and monitored logic-output status.
  • Integrates with the M-Series power/controller carrier architecture.
  • Allows system power to be planned around actual load and temperature requirements.

Technical FAQs

What is the function of the Emerson VE5008 KJ1501X1-BC2 power supply?

It converts DC input power into regulated voltage rails for compatible DeltaV M-Series control hardware. The supply operates through the system’s power/controller carrier and provides the electrical power needed by the connected controller and I/O components.

Can the KJ1501X1-BC2 operate from both 12 VDC and 24 VDC input sources?

The KJ1501X1-BC2 supports specified 12 VDC and 24 VDC input arrangements. The allowable input range and available output current differ according to the selected input voltage, so the input source and load must be checked against the applicable ratings.

Can the KJ1501X1-BC2 replace another DeltaV M-Series power supply?

Not automatically. Different power-supply variants can have different input requirements, output capacities, and carrier compatibility. Confirm the full part number, input source, output ratings, and intended system configuration before selecting a replacement.

What should I check if the KJ1501X1-BC2 triggers a power alarm?

Check the DC input voltage, input wiring, carrier connections, and output loads. The alarm relay monitors the specified logic-output conditions, so an abnormal relay state may indicate that a monitored output is outside its tolerance. Measure the output rails and investigate overloads or connected-hardware faults before replacing the supply.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501