• Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply
  • Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply
  • Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply
  • Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply
12 VDC nominal Conversion Type DC-to-DC Primary Function Converts 24 VDC input power to 12 VDC output Dimensions 393.7 × 63.5 × 127 mm Weight 2.63 kg Product Features DC-to-DC conversi……
Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply
  • Emerson
  • VE5005
  • Power Supply
  • USA
  • 393.7 × 63.5 × 127 mm
  • 2.63 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

12 VDC nominal
Conversion Type DC-to-DC
Primary Function Converts 24 VDC input power to 12 VDC output
Dimensions 393.7 × 63.5 × 127 mm
Weight 2.63 kg

Product Features

  • DC-to-DC conversion: Converts a nominal 24 VDC input into a 12 VDC output for compatible loads.
  • Bulk power conversion: Serves as a voltage-conversion stage within an industrial control cabinet.
  • Separate voltage distribution: Allows selected devices to operate at 12 VDC while the upstream cabinet distribution remains at 24 VDC.
  • Control-system integration: Can be incorporated into an automation power architecture when the connected equipment’s electrical requirements are met.
  • Centralized installation: Keeps voltage conversion within the cabinet rather than requiring separate conversion at each device.
  • System-level power planning: Allows the upstream 24 VDC source and downstream 12 VDC loads to be assessed as part of the same power budget.

Working Principle

The VE5005 receives a nominal 24 VDC input and converts it to a nominal 12 VDC output for compatible equipment.

24 VDC Input → VE5005 → 12 VDC Output → Compatible Loads

The upstream supply provides the input energy, while the VE5005 performs the voltage conversion required by the downstream circuit. The connected device draws current according to its operating conditions, so the converter must be selected according to the output load and its startup requirements.

In a control cabinet, the input may come from a 24 VDC distribution terminal, while the output feeds a separate 12 VDC branch. The branch wiring and protection should match the connected load, and the output voltage should be checked under operating conditions rather than only when the circuit is unloaded.

When diagnosing a power issue, measuring both the converter input and output helps distinguish an upstream supply problem from a conversion-stage fault or excessive downstream load.


Role in a DeltaV Control System Power Architecture

The VE5005 functions as a DC voltage-conversion stage in a control-system power arrangement. It differs from an AC/DC supply, which converts incoming AC power, and from a controller or I/O module, which performs control processing or signal acquisition.

24 VDC Distribution → VE5005 → 12 VDC Distribution → Compatible Equipment

System Element Function
Upstream 24 VDC Supply Provides DC power to the conversion stage
24 VDC Distribution Routes input power to the VE5005
VE5005 Power Supply Converts 24 VDC input to 12 VDC output
12 VDC Distribution Routes the converted output to compatible loads
Branch-Circuit Protection Protects wiring and downstream circuits according to the installation design
Control-System Accessories Use the converted supply where their electrical requirements match
DeltaV Controller and I/O Hardware Perform control and signal-processing functions using their specified power arrangements
Grounding and Bonding Provides the protective connections required by the cabinet design

The actual arrangement depends on the connected equipment and the system’s power requirements. The 12 VDC output should only be connected to devices rated for that supply, and the VE5005 should not be assumed to power every DeltaV controller or I/O module directly.


Industrial Applications

Application Typical Use
Process Automation Providing 12 VDC to compatible auxiliary control equipment
Oil and Gas Supplying DC-powered interface devices within automation cabinets
Water Treatment Powering compatible monitoring and instrumentation accessories
Chemical Processing Converting cabinet DC power for devices requiring 12 VDC
Manufacturing Supplying lower-voltage equipment from a 24 VDC distribution system
Utility Systems Providing a separate DC voltage for compatible auxiliary loads
Control Cabinets Creating a 12 VDC branch from an existing 24 VDC source
Industrial Instrumentation Supplying devices whose specified input voltage matches the converter output

Installation and Maintenance

  1. Confirm the VE5005 model and verify that the intended application requires conversion from 24 VDC to 12 VDC.
  2. Check the upstream DC supply and confirm that its voltage and available current meet the converter’s input requirements.
  3. Isolate the power source before installation or wiring and verify that the circuit is de-energized.
  4. Mount the unit in a suitable location according to the cabinet’s installation requirements.
  5. Provide adequate clearance for wiring, ventilation, and maintenance access.
  6. Connect the 24 VDC input with the correct polarity and specified terminal arrangement.
  7. Connect the 12 VDC output only to equipment rated for that voltage.
  8. Calculate the combined downstream load and verify that the converter’s output capacity is sufficient.
  9. Check conductor sizing, branch protection, and expected voltage drop on the output circuit.
  10. Energize the converter and measure the output voltage before connecting or enabling sensitive downstream equipment.
  11. Verify the output again under normal operating load and investigate unexpected voltage variation.
  12. If a downstream device loses power, inspect the input source, wiring, protection devices, converter connections, and load current before replacing the power supply.

For installations with multiple 12 VDC loads, calculate the combined demand and account for startup current. A converter may show the expected voltage without a load but experience excessive voltage drop or shutdown when the connected equipment draws more current than the available output capacity.


Related Components

Component Function
24 VDC Power Supply Provides the upstream DC input
24 VDC Distribution Terminal Block Routes input power to the converter
VE5005 Power Supply Converts 24 VDC input into 12 VDC output
12 VDC Distribution Terminal Block Distributes converted power to downstream branches
DC Branch-Circuit Protection Protects downstream wiring and equipment
DC Power Wiring Carries input and output power between components
Protective-Earth Connection Provides protective grounding as required by the installation
Voltage Measuring Instrument Checks input and output voltage during commissioning
Compatible 12 VDC Equipment Receives power from the converter
DeltaV Controller and I/O Hardware Performs control and process-signal functions using the specified power arrangement

Recommended Related Models

Model / Product Family Product Type Typical Application
Emerson VE5003 Bulk AC to 24 VDC Power Supply Providing a 24 VDC source from an AC input
Emerson VE5005 Bulk 24 VDC to 12 VDC Power Supply Converting 24 VDC distribution to 12 VDC
Emerson VE5001 DeltaV M-Series AC/DC System Power Supply Supplying compatible M-Series control hardware
Emerson DeltaV System Power Supplies Control-system power-supply family Providing power for compatible controller and I/O arrangements
24 VDC Distribution Equipment DC power distribution components Routing upstream power to converters and other loads
12 VDC Distribution Equipment Low-voltage DC distribution components Distributing converted power to compatible equipment

Key Advantages

  • Converts nominal 24 VDC input power to nominal 12 VDC output.
  • Allows compatible lower-voltage equipment to operate from an upstream 24 VDC distribution system.
  • Separates voltage conversion from the controller and I/O signal-processing functions.
  • Supports centralized DC conversion within an industrial control cabinet.
  • Simplifies planning for systems with different DC voltage requirements.
  • Can be integrated into a structured DC distribution arrangement with suitable wiring and circuit protection.

Technical FAQs

What is the function of the Emerson VE5005 DeltaV Bulk 24 VDC to 12 VDC Power Supply?

The VE5005 converts a nominal 24 VDC input into a nominal 12 VDC output for compatible downstream equipment. It is used where the upstream DC distribution voltage differs from the input voltage required by an auxiliary device or interface.

How do I determine whether the VE5005 can supply enough current to a 12 VDC load?

Calculate the combined current demand of the connected devices, including startup and transient loads. Compare the result with the converter’s rated output capacity, and account for wiring voltage drop and branch-circuit protection. The converter’s output-current rating must be confirmed before finalizing the load configuration.

Can the VE5005 directly replace a 24 VDC power supply?

No, not where the connected equipment requires 24 VDC input. The VE5005 is intended to convert 24 VDC input into 12 VDC output. Replacing a 24 VDC source with a 12 VDC converter output could leave equipment outside its specified operating range. Confirm the voltage requirements of the load and the role of the existing supply before making a substitution.

What should I check if the VE5005 output drops when equipment is connected?

Measure the input voltage and output voltage while the downstream equipment is operating. Check whether the upstream supply can maintain its voltage under load, whether the connected devices exceed the available output capacity, and whether wiring or terminal connections introduce excessive voltage drop. If the input remains within its required range and the load is within the converter’s ratings, investigate the converter and connected circuit for faults.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501