• Schneider TM3TI4 Modicon TM3 Analog Input Module
  • Schneider TM3TI4 Modicon TM3 Analog Input Module
  • Schneider TM3TI4 Modicon TM3 Analog Input Module
  • Schneider TM3TI4 Modicon TM3 Analog Input Module
Product Overview The Schneider TM3TI4 is an analog input module in the Modicon TM3 expansion family, used to acquire temperature-related signals in compatible PLC control systems. It extends the control……
Schneider TM3TI4 Modicon TM3 Analog Input Module
  • Schneider
  • TM3TI4
  • Analog Input Module
  • France
  • 90 × 70 × 23.6 mm
  • 0.11 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Schneider TM3TI4 Modicon TM3 Analog Input Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TM3TI4 Modicon TM3 Analog Input Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TM3TI4 Modicon TM3 Analog Input Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TM3TI4 Modicon TM3 Analog Input Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider TM3TI4 is an analog input module in the Modicon TM3 expansion family, used to acquire temperature-related signals in compatible PLC control systems. It extends the controller’s ability to monitor process conditions, allowing temperature measurements to become part of an automated machine’s monitoring, sequencing, and control logic.

In applications such as industrial ovens, packaging machinery, environmental chambers, and process equipment, temperature feedback helps the controller determine whether a process is operating within its intended range. The module receives supported sensor signals and makes the resulting input information available to the controller for processing. The PLC program can then use these values for temperature monitoring, alarms, sequence transitions, or coordination with other control devices.

When selecting or replacing the TM3TI4, engineers should confirm the supported sensor types, input channel configuration, measurement range, resolution, and wiring arrangement in Schneider Electric’s official documentation. These details determine whether the module is suitable for the installed temperature sensors and the requirements of the application.


Technical Specifications

Parameter Description
Brand Schneider Electric
Model TM3TI4
Product Series Modicon TM3
Product Type Analog Input Module
Product Family Modicon TM3 Expansion Modules
Primary Function Temperature-related analog signal acquisition
System Role PLC temperature input interface
Input Signal Type Temperature sensor signals supported by the module
Input Channels 4 temperature input channels
Supported Sensor Types Verify the supported thermocouple and temperature sensor types in the official datasheet
Measurement Range Depends on the selected sensor type; refer to the manufacturer’s specifications
Measurement Resolution Refer to the official technical documentation
Conversion and Update Time Refer to the model-specific specifications
Controller Compatibility Verify using the Modicon TM3 compatibility documentation
Mounting Follow the manufacturer’s installation instructions
Wiring Use the model-specific sensor wiring diagram
Dimensions 90 × 70 × 23.6 mm
Weight 0.11 kg

Product Features

  • Temperature signal acquisition: Receives supported temperature sensor signals for monitoring process conditions through a compatible Modicon controller.
  • Four-channel measurement: Supports monitoring multiple temperature points, subject to the module’s documented input configuration.
  • PLC-based process monitoring: Makes temperature input data available to the application program for alarms, operating sequences, and process supervision.
  • Modular expansion: Adds temperature input capability to a compatible control system without requiring the entire PLC architecture to be replaced.
  • Multi-point monitoring: Can be used where several locations or stages require separate temperature feedback.
  • Sensor-specific configuration: Requires the correct sensor selection and configuration to ensure that the measured values are interpreted properly by the controller.

Working Principle

The TM3TI4 acquires signals from supported temperature sensors and supplies measurement information to the PLC through the Modicon TM3 expansion system. The controller uses this information as part of its application logic.

During operation, a connected temperature sensor responds to changes in the monitored process. The module processes the sensor signal according to its supported input type and measurement characteristics, then makes the resulting temperature data available to the controller. The PLC program can compare the measured value with configured limits, evaluate process conditions, and issue control commands through the appropriate output modules.

For example, in an industrial heating process, the controller may monitor temperatures at several points in a chamber. When a measured value reaches a configured threshold, the program can advance a process step, activate an alarm, or adjust the associated control output. The actual response depends on the application program and the equipment connected to the controller.

Accurate operation depends on selecting a supported sensor, using the correct wiring arrangement, configuring the corresponding input type, and applying suitable measurement limits. Sensor faults, incorrect wiring, or an unsuitable input configuration can cause invalid or unexpected readings.


Role in a Modicon TM3 PLC Control Architecture

System Component Role in the Control Architecture
Modicon Logic Controller Executes the control program and processes temperature measurements
TM3 Expansion Connection Transfers input data between the module and the compatible controller
TM3TI4 Analog Input Module Acquires supported temperature sensor signals for PLC processing
Temperature Sensors Measure temperature at selected machine or process locations
Digital Input Modules Provide discrete feedback such as equipment status and limit-switch signals
Digital Output Modules Execute discrete commands generated by the controller program
Analog Output Modules Provide analog command signals where required by the process
Heating or Cooling Equipment Changes process temperature in response to the relevant control system
Programming and Diagnostic Tools Support input configuration, monitoring, and troubleshooting

Industrial Applications

Application Typical Use
Industrial Ovens Monitors temperature at selected points during heating and curing processes
Packaging Machinery Tracks temperature in sealing, forming, or other temperature-sensitive machine stages
Environmental Chambers Supplies temperature measurements for environmental testing and control sequences
Plastics Processing Monitors temperature conditions in selected heating zones, subject to sensor compatibility
Food and Beverage Equipment Provides temperature feedback for process monitoring where the installed sensor type is supported
Process Skids Acquires temperature measurements for packaged industrial process systems
Laboratory and Test Equipment Monitors multiple temperature points during automated test cycles
General Machine Automation Adds temperature feedback to PLC applications that require measurement-based decisions

Installation and Maintenance

  1. Verify the model number. Confirm that the module is TM3TI4 and check the installed hardware against the equipment documentation.
  2. Check controller compatibility. Ensure that the Modicon controller supports the module and that the expansion configuration follows Schneider Electric’s system requirements.
  3. Isolate power before installation. Follow the site’s lockout/tagout procedure and verify the relevant circuits are in a safe state before handling the module or sensor wiring.
  4. Inspect the mounting location. Confirm that the module is securely mounted and that cabinet conditions meet the manufacturer’s requirements.
  5. Identify the sensor type. Check the installed temperature sensor against the sensor types supported by the TM3TI4.
  6. Review the wiring diagram. Use the official terminal assignment and sensor wiring instructions rather than assuming that all temperature sensors share the same connection method.
  7. Check sensor wiring and polarity. Verify terminal connections, conductor condition, shielding arrangements where applicable, and any polarity requirements specified for the selected sensor.
  8. Configure the input channels. Set each channel according to the connected sensor type and the applicable controller configuration instructions.
  9. Inspect the expansion connection. Confirm that the module is seated correctly and that its connection to the controller or expansion system is secure.
  10. Verify input readings. Compare the displayed values with a suitable reference measurement under controlled conditions and investigate unexpected deviations.
  11. Test alarm and control logic. Confirm that configured temperature thresholds, alarms, and process responses operate as intended without bypassing safety functions.
  12. Document maintenance findings. Record sensor types, channel assignments, configuration changes, test results, and any faults. When readings are incorrect, inspect the sensor, wiring, configuration, and controller diagnostics before deciding whether the module requires replacement.

Compatible System Components

Component Function in the System
Compatible Modicon Logic Controller Processes acquired temperature data and executes the control program
Modicon TM3 Digital Input Modules Receive discrete equipment-status and sensor signals
Modicon TM3 Digital Output Modules Execute discrete control commands from the PLC
Modicon TM3 Analog Output Modules Provide analog control signals where required
Supported Temperature Sensors Supply the temperature signals accepted by the module
Sensor Wiring and Terminal Accessories Provide the required electrical connections between sensors and the module
Heating and Cooling Equipment Regulates process temperature through the wider control system
Control Power Supply Supplies the relevant control-system circuits
Programming and Diagnostic Tools Support configuration, monitoring, and troubleshooting

Recommended Related Models

Model or Product Family Product Type Relationship
Schneider Modicon TM3 Analog Input Modules Analog Input Modules Provide alternative analog input configurations; confirm signal compatibility before selection
Schneider Modicon TM3 Digital Input Modules Discrete Input Modules Add discrete feedback from switches and sensors
Schneider Modicon TM3 Digital Output Modules Discrete Output Modules Add discrete output capability for machine control
Schneider Modicon TM3 Analog Output Modules Analog Output Modules Provide analog command signals for compatible applications
Schneider Modicon TM3 Communication Modules Communication Expansion Modules Address supported communication requirements within the system configuration
Schneider Modicon Logic Controllers Programmable Logic Controllers Process input data and coordinate the overall automation sequence

Key Advantages

  • Temperature monitoring: Brings supported temperature measurements into the PLC control program.
  • Multi-point acquisition: Supports monitoring multiple temperature locations through its documented input channels.
  • Modular expansion: Adds temperature input capability to compatible Modicon TM3 systems.
  • Program-based response: Enables the controller to use measured temperatures for alarms, sequence decisions, and process supervision.
  • Structured diagnostics: Supports troubleshooting through sensor checks, wiring inspection, input configuration, and controller monitoring.

Technical FAQs

1. What is the main function of the Schneider TM3TI4?

The TM3TI4 is a Modicon TM3 analog input module intended for temperature-related signal acquisition. It supplies measurement information from supported temperature sensors to a compatible PLC for monitoring and control logic. Confirm the exact supported sensor types in the official datasheet.

2. Which temperature sensors can be connected to the TM3TI4?

The permitted sensor types and measurement ranges must be checked in Schneider Electric’s official TM3TI4 documentation. Before connecting a sensor, verify its type, wiring requirements, measurement range, and the channel configuration supported by the module.

3. Why might the temperature reading be incorrect or unstable?

Potential causes include a damaged sensor, incorrect wiring or polarity, a loose terminal, electrical interference, an unsuitable sensor configuration, or a measurement value outside the supported range. Check the sensor and wiring first, then review the channel configuration and controller diagnostics.

4. Can the TM3TI4 be replaced with another Modicon TM3 analog input module?

Not automatically. Different analog input modules may support different signal types, sensor configurations, measurement ranges, and channel arrangements. Compare the official specifications and verify controller compatibility before selecting a replacement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501