• Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable
  • Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable
  • Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable
  • Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable
Product Overview The Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable is an industrial control-system cable associated with Foxboro I/A Series 200 equipment. Termination cables form part of……
Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable
  • Foxboro
  • RH916FJ
  • Termination Cable
  • USA
  • 3 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro RH916FJ I/A Series 200 Type 4 P/PVC Termination Cable is an industrial control-system cable associated with Foxboro I/A Series 200 equipment. Termination cables form part of the physical connection between control-system hardware and designated termination points, supporting the transfer of signals between connected assemblies.

In a distributed control system (DCS), the correct cable reference matters when maintaining existing installations. For example, during maintenance of a process-control cabinet, a technician may need to replace a cable connecting an I/O-related assembly to its associated termination hardware. Identifying the RH916FJ model helps distinguish the required cable from other interconnection cables used in the same cabinet.

The RH916FJ is relevant to spare-parts management and replacement work involving compatible Foxboro I/A Series 200 installations. Before replacement, maintenance personnel should identify the cable’s existing connection points and verify the applicable wiring arrangement.


Technical Specifications

Parameter Specification
Manufacturer Foxboro
Model RH916FJ
Product Family I/A Series 200
Product Type Type 4 P/PVC Termination Cable
Cable Length 3 meters
Cable Construction Designation P/PVC
Component Category Industrial Control-System Cable
Application Control-system termination and interconnection
System Association Foxboro I/A Series 200
Installation Context Industrial control-system installations
Replacement Reference RH916FJ
Shipping Weight 3 kg

Product Features

  • Foxboro RH916FJ model for I/A Series 200 installations.
  • Identified as a Type 4 P/PVC termination cable.
  • Used for designated cable connections within compatible control-system arrangements.
  • Relevant to maintenance of installed Foxboro automation equipment.
  • Supports replacement planning using the original cable reference.
  • Helps maintain organized connections between control-system assemblies.
  • Suitable for spare-parts identification and inventory management.
  • Requires matching the cable to the installed connector and wiring arrangement.
  • Useful during planned maintenance, cable replacement, and cabinet refurbishment.
  • Can be recorded by model reference in maintenance and procurement documentation.

Working Principle

The RH916FJ serves as a physical connection within the applicable control-system installation. It carries the signals assigned to its cable path between compatible connection points. The specific signals and their direction depend on the connected equipment and the system wiring arrangement.

During replacement, maintenance personnel identify the cable’s two connection points and record the existing routing before disconnecting it. The replacement is then installed in the corresponding position, with both ends checked against the equipment wiring documentation.

In a control cabinet, a termination cable may form part of the connection between system hardware and termination components. The cable itself does not process control logic; signal acquisition, output handling, and control functions are performed by the associated automation equipment.


Role in a Foxboro I/A Series 200 Control Architecture

The RH916FJ is a cable-level component within the applicable Foxboro I/A Series 200 installation. Its specific position depends on the hardware configuration and the termination arrangement used by the system.

Control-System Hardware → RH916FJ Termination Cable → Designated Termination or Interface Point → Associated I/O and Control-System Functions

System Element Function
Foxboro RH916FJ Provides the designated cable connection within a compatible installation
I/A Series 200 Equipment Provides the control-system hardware associated with the cable
Termination Hardware Provides connection points for the applicable wiring arrangement
I/O Assembly Handles input or output signals where included in the installed architecture
Controller Executes control logic and processes system data
Engineering or Maintenance Station Supports configuration, monitoring, and troubleshooting where available
Field Instrument or Device Supplies measurements or receives control signals, depending on the signal path

Industrial Applications

Application Typical Use
Process Manufacturing Maintaining cable connections in an established process-control system
Chemical Processing Replacing identified termination cables during planned cabinet maintenance
Oil and Gas Facilities Supporting maintenance of compatible installed automation equipment
Water and Wastewater Treatment Maintaining control-system interconnections in plant automation cabinets
Power and Utility Operations Managing spare cables for existing control-system installations
Industrial Production Lines Restoring cable connections after equipment maintenance
Distributed Control Systems Maintaining physical connections between compatible system assemblies
Control Cabinet Refurbishment Replacing cables that require service or show signs of damage
Plant Maintenance Programs Tracking cable references and replacement requirements
Legacy Automation Systems Identifying specific cable models for existing Foxboro installations

Installation and Maintenance

  1. Confirm that the existing cable reference is RH916FJ before ordering or beginning replacement work.
  2. Identify the equipment and connection points served by the installed cable.
  3. Compare the replacement cable with the existing cable, including the connector arrangement.
  4. Follow approved electrical safety and isolation procedures before disconnecting control-system wiring.
  5. Label both ends of the original cable to preserve the existing connection mapping.
  6. Inspect the cable route for sharp bends, abrasion, crushing, and excessive tension.
  7. Examine the mating connectors and termination points for contamination, damaged contacts, or loose fittings.
  8. Verify that the replacement cable is intended for the same system position as the original.
  9. Route and secure the cable according to the equipment installation requirements and cabinet wiring practices.
  10. Check both cable ends against the recorded labels and applicable wiring documentation.
  11. After installation, follow the approved maintenance procedure to confirm that the affected equipment and associated signals operate correctly.
  12. Update the maintenance record with the cable reference, installation location, replacement date, and inspection findings.

Compatible System Components

Component Category Function
Foxboro I/A Series 200 Hardware Control-system equipment associated with the cable’s product family
Termination Assembly Provides the relevant cable connection point, depending on the installation
I/O Assembly Handles the applicable input or output signals
Controller or Control Processor Executes control logic and processes system data
Cabinet Wiring and Cable Supports Maintain the physical routing and organization of connections
Connector and Interface Hardware Provides the mating connection for the cable
Engineering and Maintenance Tools Support system checks and troubleshooting
Plant Spare-Parts Inventory Records the cable reference for maintenance and procurement

Recommended Related Models

Model / Product Category Product Type Typical Application
Foxboro RH916FJ Type 4 P/PVC Termination Cable Replacement of the same cable reference
Foxboro I/A Series 200 Hardware Industrial Control-System Hardware Identifying the equipment served by the cable
Foxboro Termination Assemblies Termination Hardware Checking the cable’s connection arrangement
Foxboro I/O Modules Input / Output Modules Identifying the signal-processing hardware in the installation
Foxboro Control-System Components Control-System Hardware Maintaining the wider installed automation system
Industrial Control Cables Control-System Interconnection Cables Considering alternatives only where the system documentation permits substitution

Key Advantages

  • Specific model identification for maintenance and procurement.
  • Associated with the Foxboro I/A Series 200 product family.
  • Useful for restoring an existing cable connection.
  • Supports spare-parts planning for installed automation systems.
  • Helps distinguish the required cable from unrelated wiring components.
  • Simplifies cable-reference tracking in maintenance records.

Technical FAQs

What is the RH916FJ used for?

The RH916FJ is identified as a Foxboro I/A Series 200 Type 4 P/PVC termination cable. It serves as a physical cable connection within the applicable control-system arrangement.

Can the RH916FJ be replaced with another I/A Series cable?

A different cable should not be treated as a direct substitute solely because it belongs to the same product family. The connector arrangement, cable construction, signal assignment, and system compatibility should match the requirements of the installation.

What should be checked before installing an RH916FJ replacement?

Confirm the full model reference, intended connection points, connector arrangement, cable routing, and applicable wiring documentation. Labeling the existing cable before removal can help prevent connection errors.

What could cause a control-system problem after replacing the RH916FJ?

Potential causes include an incorrectly seated connector, a connection made to the wrong point, damaged mating hardware, cable damage, or a fault elsewhere in the connected I/O and control-system path. Check the physical connections and follow the equipment’s approved troubleshooting procedure.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501