Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Foxboro P0916DG is an I/A Series 200 Type 1 P/PVC termination cable used to connect field wiring with the appropriate termination assembly in Foxboro process automation systems. It belongs to the Type 1 P/PVC termination cable family used with I/A Series 200 fieldbus modules and related termination assemblies.
The cable provides the wiring path between the field termination side and the associated FBM interface. This allows field signals to be routed into the I/A Series control system without requiring individual field wires to be connected directly to the module terminals.
P0916DG is particularly relevant to installations where an existing I/A Series 200 field wiring arrangement needs to be maintained or serviced. The P/PVC construction uses a polyurethane outer jacket with semi-rigid PVC primary conductor insulation, making the cable suitable for conventional industrial control cabinet and field termination applications.
The P0916DG has been superseded in the current cable family by RH916DG. When maintaining an existing installation, the original P0916DG designation can still be important for identifying installed wiring, spare parts, and historical system documentation.
| Parameter | Specification |
|---|---|
| Product | P0916DG |
| Product Family | I/A Series 200 Termination Cable |
| Cable Type | Type 1 |
| Cable Construction | P/PVC |
| Application | Field Wiring / Termination Assembly Connection |
| System | Foxboro I/A Series 200 |
| Cable Jacket | Polyurethane |
| Primary Conductor Insulation | Semi-rigid PVC |
| Temperature Range | -20 to +80°C (-4 to +176°F) |
| Replacement Model | RH916DG |
| Cable Length | 20 meters |
| Shipping Weight | 3 kg |
The P0916DG functions as an interconnection path rather than an active electronic device. Field conductors are brought into the termination assembly, while the cable carries the corresponding signal and circuit connections toward the associated I/A Series 200 interface.
During normal operation, process signals from field instruments or discrete devices pass through the field termination arrangement and continue through the termination cable to the connected FBM circuitry. Output and control circuits can use the same wiring path in the opposite direction.
The cable itself does not perform signal conversion, isolation, amplification, or control logic. Its main function is to maintain the required electrical connections between the termination assembly and the I/A Series control hardware.
For maintenance work, the cable identification is important because Type 1 termination cables are available in different cable constructions and lengths. Matching the installed termination arrangement and cable type helps avoid wiring errors during replacement.
| System Element | Role |
|---|---|
| Field Instruments | Generate measurement signals or receive control signals |
| Field Wiring | Carries signals between field devices and the termination assembly |
| Type 1 Termination Assembly | Provides the field-side termination interface |
| P0916DG | Connects the termination assembly wiring to the system interface |
| Foxboro FBM | Receives input signals or sends output/control signals |
| I/A Series 200 Control System | Processes field data and executes control functions |
| Operator / Engineering Station | Provides monitoring, configuration, diagnostics, and control functions |
| Application | Typical Use |
|---|---|
| Process Control Systems | Field signal wiring between termination hardware and I/A Series 200 interfaces |
| Chemical Processing | Connection of instrumentation and control circuits in process automation cabinets |
| Oil and Gas | Maintenance and replacement of existing Foxboro field wiring assemblies |
| Power and Utilities | Signal routing between field termination equipment and control modules |
| Manufacturing Plants | Integration of field devices with established I/A Series 200 control architectures |
| System Maintenance | Replacement of aging or damaged termination cables |
| Legacy DCS Upgrades | Identification and replacement of existing P0916-series wiring |
| Component | Function |
|---|---|
| Foxboro I/A Series 200 FBM | Provides the system-side field I/O interface |
| Type 1 Termination Assembly | Provides the field-side connection point |
| Termination Assembly Adapter | Alternative interface arrangement used in supported upgrade configurations |
| Field Wiring | Connects process instruments and control devices to the termination assembly |
| I/A Series Control System | Processes field signals and executes control functions |
| Model | Application / Relationship |
|---|---|
| RH916DG | Current replacement model for P0916DG in the Type 1 P/PVC termination cable family |
| P0916DF | Type 1 P/PVC termination cable for a shorter cable run |
| P0916DH | Type 1 P/PVC termination cable for a longer cable run |
| P0916DJ | Type 1 P/PVC termination cable for extended cable runs |
| RH916DE | Current Type 1 P/PVC cable for applications requiring a shorter termination connection |
The P0916DG is a Type 1 P/PVC termination cable used to connect compatible field termination assemblies with Foxboro I/A Series 200 system interfaces.
P0916DG is a legacy model. RH916DG is the corresponding successor in the current Type 1 P/PVC termination cable family.
P/PVC refers to a polyurethane outer jacket combined with semi-rigid PVC primary conductor insulation.
RH916DG is the designated successor to P0916DG in the same Type 1 P/PVC cable family. Before replacement, the installed termination assembly and system wiring should still be checked against the application requirements.