• Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable
  • Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable
  • Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable
  • Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable
Product Overview The Foxboro P0916DG is an I/A Series 200 Type 1 P/PVC termination cable used to connect field wiring with the appropriate termination assembly in Foxboro process automation systems. It ……
Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable
  • Foxboro
  • P0916DG
  • Termination Cable
  • USA
  • 20 meters
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro P0916DG I/A Series 200 Type 1 P/PVC Termination Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro P0916DG is an I/A Series 200 Type 1 P/PVC termination cable used to connect field wiring with the appropriate termination assembly in Foxboro process automation systems. It belongs to the Type 1 P/PVC termination cable family used with I/A Series 200 fieldbus modules and related termination assemblies.

The cable provides the wiring path between the field termination side and the associated FBM interface. This allows field signals to be routed into the I/A Series control system without requiring individual field wires to be connected directly to the module terminals.

P0916DG is particularly relevant to installations where an existing I/A Series 200 field wiring arrangement needs to be maintained or serviced. The P/PVC construction uses a polyurethane outer jacket with semi-rigid PVC primary conductor insulation, making the cable suitable for conventional industrial control cabinet and field termination applications.

The P0916DG has been superseded in the current cable family by RH916DG. When maintaining an existing installation, the original P0916DG designation can still be important for identifying installed wiring, spare parts, and historical system documentation.


Technical Specifications

Parameter Specification
Product P0916DG
Product Family I/A Series 200 Termination Cable
Cable Type Type 1
Cable Construction P/PVC
Application Field Wiring / Termination Assembly Connection
System Foxboro I/A Series 200
Cable Jacket Polyurethane
Primary Conductor Insulation Semi-rigid PVC
Temperature Range -20 to +80°C (-4 to +176°F)
Replacement Model RH916DG
Cable Length 20 meters
Shipping Weight 3 kg

Product Features

  • Type 1 P/PVC termination cable for Foxboro I/A Series 200 systems.
  • Intended for connection between field wiring and compatible termination assemblies.
  • Polyurethane outer jacket with semi-rigid PVC conductor insulation.
  • Suitable for process automation control cabinet wiring.
  • Supports organized field signal routing between termination hardware and FBM interfaces.
  • Useful for maintenance, replacement, and restoration of existing I/A Series 200 installations.
  • P0916DG identification remains useful when matching legacy system documentation and installed cable assemblies.
  • Superseded by the RH916DG model within the current termination cable family.

Working Principle

The P0916DG functions as an interconnection path rather than an active electronic device. Field conductors are brought into the termination assembly, while the cable carries the corresponding signal and circuit connections toward the associated I/A Series 200 interface.

During normal operation, process signals from field instruments or discrete devices pass through the field termination arrangement and continue through the termination cable to the connected FBM circuitry. Output and control circuits can use the same wiring path in the opposite direction.

The cable itself does not perform signal conversion, isolation, amplification, or control logic. Its main function is to maintain the required electrical connections between the termination assembly and the I/A Series control hardware.

For maintenance work, the cable identification is important because Type 1 termination cables are available in different cable constructions and lengths. Matching the installed termination arrangement and cable type helps avoid wiring errors during replacement.


Role in an I/A Series 200 Field Wiring Architecture

System Element Role
Field Instruments Generate measurement signals or receive control signals
Field Wiring Carries signals between field devices and the termination assembly
Type 1 Termination Assembly Provides the field-side termination interface
P0916DG Connects the termination assembly wiring to the system interface
Foxboro FBM Receives input signals or sends output/control signals
I/A Series 200 Control System Processes field data and executes control functions
Operator / Engineering Station Provides monitoring, configuration, diagnostics, and control functions

Industrial Applications

Application Typical Use
Process Control Systems Field signal wiring between termination hardware and I/A Series 200 interfaces
Chemical Processing Connection of instrumentation and control circuits in process automation cabinets
Oil and Gas Maintenance and replacement of existing Foxboro field wiring assemblies
Power and Utilities Signal routing between field termination equipment and control modules
Manufacturing Plants Integration of field devices with established I/A Series 200 control architectures
System Maintenance Replacement of aging or damaged termination cables
Legacy DCS Upgrades Identification and replacement of existing P0916-series wiring

Installation and Maintenance

  1. Confirm the existing I/A Series 200 termination assembly and FBM configuration before removing the installed cable.
  2. Verify that the replacement cable corresponds to the required Type 1 P/PVC termination arrangement.
  3. Isolate the relevant control and field circuits according to the plant maintenance procedure before disconnecting the cable.
  4. Record the existing cable routing and connector positions before removal, especially in densely populated termination cabinets.
  5. Inspect the termination assembly interface for damaged connectors, loose terminals, contamination, or mechanical wear.
  6. Route the replacement cable along the established wiring path and avoid unnecessary sharp bends or mechanical stress.
  7. Keep the cable separated from wiring routes that may introduce excessive electrical interference where the cabinet installation requires segregation.
  8. Confirm connector engagement and mechanical locking before restoring the associated system circuits.
  9. Check field-to-FBM signal continuity after installation when the maintenance procedure requires cable verification.
  10. Verify that the corresponding I/O channels receive or transmit the expected signals after the system is returned to operation.
  11. Compare cable identification with the plant wiring drawings and maintenance records before closing the cabinet.
  12. Keep records of the installed cable model and replacement history to simplify future maintenance of legacy I/A Series 200 installations.

Related Components

Component Function
Foxboro I/A Series 200 FBM Provides the system-side field I/O interface
Type 1 Termination Assembly Provides the field-side connection point
Termination Assembly Adapter Alternative interface arrangement used in supported upgrade configurations
Field Wiring Connects process instruments and control devices to the termination assembly
I/A Series Control System Processes field signals and executes control functions

Recommended Related Models

Model Application / Relationship
RH916DG Current replacement model for P0916DG in the Type 1 P/PVC termination cable family
P0916DF Type 1 P/PVC termination cable for a shorter cable run
P0916DH Type 1 P/PVC termination cable for a longer cable run
P0916DJ Type 1 P/PVC termination cable for extended cable runs
RH916DE Current Type 1 P/PVC cable for applications requiring a shorter termination connection

Key Advantages

  • Matches Foxboro I/A Series 200 termination architecture.
  • Supports organized field-to-FBM wiring.
  • Uses Type 1 P/PVC cable construction.
  • Suitable for maintenance of established I/A Series 200 installations.
  • Provides a direct replacement path through the RH916DG successor model.
  • Helps simplify identification of legacy termination wiring.

Technical FAQs

What is the Foxboro P0916DG used for?

The P0916DG is a Type 1 P/PVC termination cable used to connect compatible field termination assemblies with Foxboro I/A Series 200 system interfaces.

Is P0916DG still the current model?

P0916DG is a legacy model. RH916DG is the corresponding successor in the current Type 1 P/PVC termination cable family.

What does P/PVC mean for the P0916DG cable?

P/PVC refers to a polyurethane outer jacket combined with semi-rigid PVC primary conductor insulation.

Can P0916DG be replaced directly by RH916DG?

RH916DG is the designated successor to P0916DG in the same Type 1 P/PVC cable family. Before replacement, the installed termination assembly and system wiring should still be checked against the application requirements.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501