The Foxboro RH916DF is an I/A Series 200 Type 1 P/PVC termination cable used to connect compatible fieldbus modules with their associated termination assemblies. It is part of the RH916 termination cable family for Foxboro distributed control system field I/O installations.
The RH916DF is the 15-meter configuration in the Type 1 P/PVC cable range. It is used where the termination assembly and fieldbus module require a longer physical connection within the control system installation.
The cable provides a preassembled signal path between the termination assembly and the I/O module, reducing the need for individually wired connections between these two parts of the I/O architecture.
RH916DF supersedes the earlier P0916DF designation. The Type 1 P/PVC construction uses a polyurethane outer jacket and semi-rigid PVC primary conductor insulation, with a specified temperature range of -20 to +80 °C.
| Parameter | Specification |
|---|---|
| Product Family | I/A Series 200 |
| Product Type | Type 1 P/PVC Termination Cable |
| Cable Series | RH916 |
| Cable Type | Type 1 |
| Cable Construction | P/PVC |
| Outer Jacket | Polyurethane |
| Primary Conductor Insulation | Semi-Rigid PVC |
| Application | I/A Series 200 Field I/O |
| Connection Function | Fieldbus Module to Termination Assembly |
| System Application | Distributed Control System |
| Installation | Control Cabinets and I/O Enclosures |
| Temperature Range | -20 to +80 °C |
| Previous Model | P0916DF |
| Cable Length | 15 meters |
| Shipping Weight | 3 kg |
The RH916DF serves as the electrical connection between the fieldbus module and the associated termination assembly. It does not perform signal processing or control functions itself.
Field devices are wired to the termination assembly, where the corresponding field circuits are organized and connected to the termination cable. The RH916DF then carries these signals to the fieldbus module.
For input channels, signals from transmitters, sensors, switches, or other field devices travel through the termination assembly and cable to the I/O module for processing. For output channels, signals generated by the control system travel through the same connection in the opposite direction toward the field termination point.
The 15-meter cable length allows the termination assembly and fieldbus equipment to be installed with greater separation while maintaining the required electrical connection within the I/A Series 200 I/O architecture.
| System Layer | Typical Component | Role |
|---|---|---|
| Field Device Layer | Sensors, transmitters, switches, actuators | Generates or receives process signals |
| Field Wiring Layer | Field Cables | Connects field devices with termination hardware |
| Termination Layer | I/A Series 200 Termination Assembly | Provides organized field wiring connections |
| Cable Interface Layer | RH916DF | Connects termination hardware with the fieldbus module |
| I/O Layer | I/A Series 200 Fieldbus Module | Processes field input and output signals |
| Control Layer | I/A Series Controller | Executes process control logic |
| Operator Layer | HMI or Operator Workstation | Provides process monitoring and operator control |
| Application | Use of RH916DF |
|---|---|
| I/A Series 200 I/O Cabinets | Connects fieldbus modules with termination assemblies |
| Process Control Systems | Carries field signals between termination and I/O hardware |
| Distributed Field I/O | Provides the physical connection within the I/O subsystem |
| Control Cabinet Expansion | Supports additional field I/O installation |
| System Maintenance | Replaces an existing compatible termination cable |
| Extended Cabinet Wiring | Provides a 15-meter connection where greater cable reach is required |
| Component | Function |
|---|---|
| I/A Series 200 Fieldbus Module | Provides the field I/O interface |
| Type 1 Termination Assembly | Provides field wiring termination |
| Field Wiring | Connects process instruments and field devices |
| I/A Series Controller | Processes I/O data and executes control functions |
| Control Cabinet | Houses fieldbus, termination, and cable assemblies |
| I/A Series 200 I/O Subsystem | Provides the overall field signal interface |
| Model | Product | Application |
|---|---|---|
| RH916DA | I/A Series 200 Type 1 P/PVC Termination Cable | 0.5-meter cable configuration |
| RH916DB | I/A Series 200 Type 1 P/PVC Termination Cable | 1-meter cable configuration |
| RH931RM | I/A Series 200 Type 1 P/PVC Termination Cable | 2-meter cable configuration |
| RH916DC | I/A Series 200 Type 1 P/PVC Termination Cable | 3-meter cable configuration |
| RH916DD | I/A Series 200 Type 1 P/PVC Termination Cable | 5-meter cable configuration |
| RH916DE | I/A Series 200 Type 1 P/PVC Termination Cable | 10-meter cable configuration |
| RH916DG | I/A Series 200 Type 1 P/PVC Termination Cable | 20-meter cable configuration |
The RH916DF is a Type 1 P/PVC termination cable used to connect compatible I/A Series 200 fieldbus modules with their associated termination assemblies.
The RH916DF has a Cable Length of 15 meters. It is the 15-meter version of the RH916 Type 1 P/PVC termination cable family.
RH916DF is the newer designation that supersedes P0916DF. Both identify the 15-meter Type 1 P/PVC termination cable configuration for the applicable Foxboro I/A Series field I/O systems.
The specified temperature range for the Type 1 P/PVC cable construction is -20 to +80 °C. The P/PVC construction consists of a polyurethane outer jacket and semi-rigid PVC primary conductor insulation.