• Foxboro RH916DB I/A Series Termination Cable
  • Foxboro RH916DB I/A Series Termination Cable
  • Foxboro RH916DB I/A Series Termination Cable
  • Foxboro RH916DB I/A Series Termination Cable
Product Overview The Foxboro RH916DB is an I/A Series termination cable used to connect field termination hardware with the associated I/A Series I/O equipment. It forms part of the cabinet-level interc……
Foxboro RH916DB I/A Series Termination Cable
  • Foxboro
  • RH916DB
  • Termination Cable
  • USA
  • 1 meter
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 44

Our advantage

Foxboro RH916DB I/A Series Termination Cable

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Foxboro RH916DB I/A Series Termination Cable

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Foxboro RH916DB I/A Series Termination Cable

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Foxboro RH916DB I/A Series Termination Cable

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Foxboro RH916DB is an I/A Series termination cable used to connect field termination hardware with the associated I/A Series I/O equipment. It forms part of the cabinet-level interconnection between the field wiring termination section and the electronic I/O section of a Foxboro process-control system.

In an I/A Series installation, field instruments are normally connected through an organized termination arrangement before their circuits reach the electronic I/O hardware. The RH916DB carries the corresponding electrical connections between these system sections, helping maintain a structured signal path inside the control cabinet.

The RH916DB is a passive cable assembly rather than an active I/O device. It does not independently process field signals or execute control logic. Its function is to preserve the electrical connection between the termination arrangement and the associated I/O interface.

For maintenance and replacement work, the cable should be considered together with the termination assembly, associated I/O hardware, cabinet wiring, and applicable system drawings. Correct identification of both ends is particularly important because the cable forms part of the fixed point-to-point signal architecture.


Technical Specifications

Parameter Specification
Product Model RH916DB
Product Type I/A Series Termination Cable
Product Family Foxboro I/A Series
Series I/A Series
Cable Function I/O Termination Interconnection
System Role Termination-to-I/O Signal Connection
Interface Function Electrical Signal Interconnection
Component Type Passive Cable Assembly
Application I/A Series I/O Cabinet Wiring
Signal Path Termination Hardware to Associated I/O Hardware
Installation Control-System Cabinet
Cable Application Field I/O Signal Routing
Cable Length 1 meter
Shipping Weight 3 kg

Product Features

  • Termination cable for Foxboro I/A Series control-system installations
  • Connects termination hardware with associated I/A Series I/O equipment
  • Functions as a passive electrical signal interconnection
  • Supports organized field I/O wiring inside control cabinets
  • Maintains the physical separation between field termination and electronic I/O hardware
  • Suitable for established Foxboro I/A Series installations
  • Useful for replacement of existing termination cables during maintenance
  • Supports structured routing of field signal connections
  • Suitable for cabinet refurbishment and retrofit service work
  • Helps preserve the existing I/A Series I/O wiring architecture

Working Principle

The RH916DB provides the electrical path between an I/A Series termination arrangement and the corresponding I/O hardware. It carries the circuit connections without independently interpreting, conditioning, or processing the process signals.

For an input circuit, the general signal path can be represented as:

Field Device → Field Wiring → Termination Hardware → RH916DB → I/A Series I/O Hardware → Control System

A transmitter, switch, or other field instrument sends its signal through the field wiring to the termination hardware. The RH916DB then carries the associated connection toward the I/O interface, where the applicable I/A Series electronics process the signal.

For an output circuit, the direction is reversed:

Control System → I/A Series I/O Hardware → RH916DB → Termination Hardware → Field Device

In this arrangement, the cable carries the output connection toward the field device through the termination hardware.

Because the RH916DB is part of a fixed interconnection, correct cable identification is essential during maintenance. Both ends should be matched to the appropriate termination and I/O interfaces using the cabinet drawings or termination documentation. A physically connected cable can still create an incorrect signal path if it is installed at the wrong connection point.


Role in a Foxboro I/A Series I/O Control Architecture

The RH916DB occupies the interconnection layer between the field termination hardware and the electronic I/O section. It maintains the physical signal path while leaving signal processing and control functions to the associated I/A Series electronics.

Control Architecture Layer Typical Component Function
Process Control Foxboro I/A Series Control System Executes process-control strategies and system functions
I/O Processing I/A Series I/O Hardware Processes field input and output signals
Interconnection RH916DB Termination Cable Carries I/O connections between termination and I/O hardware
Termination I/A Series Termination Hardware Provides organized field-wiring connections
Field Interface Field Wiring and Instruments Connects process devices with the control system
Process Equipment Pumps, Valves, Motors, Machinery Generates or responds to process conditions
Engineering / HMI Operator and Engineering Stations Provides monitoring and system interaction

Industrial Applications

Application Cable Role
Process Control Systems Connects I/A Series termination hardware with associated I/O equipment
Chemical Processing Routes instrumentation circuits between field termination and I/O hardware
Oil and Gas Facilities Supports field-signal interconnection in established I/A Series systems
Power Generation Maintains signal connections between termination and control-system I/O
Water and Wastewater Supports organized instrumentation wiring within control cabinets
Manufacturing Plants Used in Foxboro I/A Series automation cabinets
Continuous Process Plants Maintains fixed signal paths between field termination and electronic I/O
System Maintenance Replaces damaged or aging termination cables without redesigning the I/O architecture

Installation and Maintenance

  1. Confirm the part number — Verify that the RH916DB matches the existing I/A Series termination and I/O arrangement before installation.
  2. Review system documentation — Check cabinet drawings, termination schedules, and I/O documentation to identify the intended connection points.
  3. Isolate the relevant equipment — Follow the plant’s approved shutdown, isolation, and electrical safety procedures before disconnecting the existing cable.
  4. Identify both cable ends — Confirm the termination-side and I/O-side connection points before removing the installed cable.
  5. Inspect the cable assembly — Check the cable and accessible connection areas for physical damage, contamination, corrosion, or other visible abnormalities.
  6. Remove the existing cable carefully — Disconnect both ends according to the applicable maintenance procedure without applying unnecessary force to the connectors or adjacent wiring.
  7. Verify the cable routing — Confirm that the replacement follows the established cabinet routing and does not interfere with nearby equipment or wiring.
  8. Install the replacement cable — Connect the RH916DB to the correct termination and I/O interfaces and ensure that both connections are fully seated.
  9. Check connection identification — Compare both ends with the cabinet documentation to prevent incorrect point-to-point connections.
  10. Perform continuity verification — Where applicable, verify the completed cable path before restoring the I/O section to normal operation.
  11. Perform a controlled signal check — Confirm representative input or output points and investigate any unexpected signal behavior after installation.
  12. Document the maintenance work — Record the installed cable model, associated termination hardware, I/O equipment, and test results for future service activities.

Related Components

Component Function in the System
Foxboro I/A Series I/O Module Processes connected field input or output signals
I/A Series Termination Assembly Provides the field-wiring termination point
RH916DB Termination Cable Connects termination hardware with associated I/O equipment
Field Wiring Carries signals between field devices and termination hardware
Field Transmitter Supplies process measurement signals
Control Valve / Actuator Receives control commands from the I/O system
I/O Cabinet Houses termination, cable, and I/O hardware
Foxboro I/A Series Control System Performs process monitoring and control functions

Recommended Related Models

Model Product Type Series
Foxboro RH916DA I/A Series Termination Cable I/A Series
Foxboro RH916DB I/A Series Termination Cable I/A Series
Foxboro RH916DC I/A Series Termination Cable I/A Series
Foxboro P0916DB I/A Series Termination Cable I/A Series
Foxboro I/A Series Termination Cables I/O Interconnection Cable I/A Series

Key Advantages

  • Provides a dedicated electrical connection between I/A Series termination and I/O hardware.
  • Maintains the established field-wiring architecture of Foxboro control cabinets.
  • Functions as a passive signal path without independent signal processing.
  • Supports organized routing of field I/O connections.
  • Suitable for maintenance and replacement of existing I/A Series installations.
  • Helps preserve established point-to-point wiring during cabinet service work.

Technical FAQs

What is the purpose of the Foxboro RH916DB?

The RH916DB is an I/A Series termination cable used to connect termination hardware with associated I/A Series I/O equipment. It carries the corresponding electrical connections without independently processing the signals.

Is the RH916DB an active I/O component?

No. The RH916DB is a passive cable assembly. Signal processing and control functions are performed by the associated I/A Series I/O and control-system hardware.

What should be checked before replacing the RH916DB?

The termination arrangement, associated I/O hardware, cable connection points, cabinet documentation, and routing should be verified before removing the existing cable. Both ends should be positively identified before reconnection.

What should be checked after installing a replacement termination cable?

The cable connections should be checked against the system documentation, followed where applicable by continuity verification and a controlled signal test. Any unexpected signal loss or incorrect point indication should be investigated before returning the system to normal operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501