• Schneider TM2AMI8HT Modicon M238 Analog Input Module
  • Schneider TM2AMI8HT Modicon M238 Analog Input Module
  • Schneider TM2AMI8HT Modicon M238 Analog Input Module
  • Schneider TM2AMI8HT Modicon M238 Analog Input Module
Product Overview The Schneider TM2AMI8HT is a Modicon M238 analog input module used to expand the analog measurement capability of an M238 control system. It provides an interface for bringing multiple ……
Schneider TM2AMI8HT Modicon M238 Analog Input Module
  • Schneider
  • TM2AMI8HT
  • Analog Input Module
  • France
  • 23.5× 70× 90 mm
  • 0.085 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Schneider TM2AMI8HT Modicon M238 Analog Input Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider TM2AMI8HT Modicon M238 Analog Input Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider TM2AMI8HT Modicon M238 Analog Input Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider TM2AMI8HT Modicon M238 Analog Input Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider TM2AMI8HT is a Modicon M238 analog input module used to expand the analog measurement capability of an M238 control system. It provides an interface for bringing multiple continuously varying field signals into the controller, making it suitable for machines and compact process systems that require more analog acquisition than the base controller configuration can provide.

In a typical installation, sensors or transmitters measure variables such as temperature, pressure, level, flow, position, or other process conditions. Their analog signals are wired to the TM2AMI8HT, where the measurements are acquired and made available to the M238 controller. The controller can then use these values for sequencing, monitoring, alarm handling, limits, or control functions.

The module is useful when several analog measurement points need to be integrated into the same M238 automation architecture. It can be combined with digital I/O and other TM2 expansion modules, allowing the overall I/O arrangement to match the instrumentation and control requirements of the machine.


Technical Specifications

Parameter Specification
Product Model TM2AMI8HT
Product Type Analog Input Module
Product Family Modicon M238
Series Modicon TM2
Module Function Analog Signal Acquisition
I/O Type Analog Input
Application Machine and Process Automation
System Integration Modicon M238 Controller
Signal Processing Analog Measurement Acquisition
Field Interface Analog Sensors and Transmitters
Control Architecture M238 Expansion I/O
Installation Control Cabinet / Automation Panel
Dimensions 23.5 × 70 × 90 mm
Weight 0.085 kg

Product Features

  • Expands analog input capability within a Modicon M238 control system.
  • Provides a dedicated interface for multiple field measurement signals.
  • Acquires continuously varying signals from compatible sensors and transmitters.
  • Integrates into the Modicon TM2 expansion architecture.
  • Allows additional process measurements to be incorporated into M238 application logic.
  • Suitable for machine automation and compact process-control applications.
  • Can operate alongside digital and other analog I/O expansion modules.
  • Supports centralized analog signal acquisition within an automation cabinet.
  • Useful for applications where several process values must be monitored by a single controller.
  • Helps extend an existing M238 system without replacing the main controller.

Working Principle

The TM2AMI8HT serves as the analog acquisition stage between field instrumentation and the Modicon M238 controller.

Each connected sensor or transmitter produces an analog electrical signal corresponding to a measured physical variable. The signal enters the appropriate input of the TM2AMI8HT, where it is acquired and converted into measurement data that the M238 controller can process.

Field Sensors / Transmitters → TM2AMI8HT → M238 Controller → Application Logic / Monitoring

The controller can associate the acquired values with individual process variables and use them in the control program. For example, measurements from several sensors can be monitored simultaneously, compared with operating limits, or used as feedback for machine sequences.

The module’s role is focused on signal acquisition and communication with the controller’s I/O architecture. The main control decisions remain within the M238 application program.


Role in a Modicon M238 Control Architecture

The TM2AMI8HT forms part of the analog field-input layer of a Modicon M238 system. Its role is to collect multiple analog measurements and make them available to the controller alongside other digital and analog I/O information.

System Layer Typical Component Function
Application Control Modicon M238 Controller Executes machine or process control logic
Analog Acquisition TM2AMI8HT Acquires analog measurements from field devices
Digital I/O Modicon TM2 Digital I/O Modules Handles discrete machine signals
Field Measurement Sensors / Transmitters Measures process and machine variables
Field Wiring Terminal Connections Carries measurement signals to the analog module
Control Equipment Drives / Valves / Actuators Responds to commands from the control system
Operator Interface HMI Displays measured values, alarms, and operating status

Industrial Applications

Application Typical Use
Machine Automation Collects multiple analog feedback signals for machine control
Temperature Monitoring Acquires temperature measurements from several sensing points
Pressure Monitoring Brings pressure measurements into M238 control logic
Level Measurement Integrates continuous level measurements into the automation system
Flow Monitoring Acquires flow-related process measurements from field instruments
Process Equipment Monitors several continuously varying process conditions
Packaging Machinery Supports analog sensing and process-value supervision
Material Handling Provides analog feedback for equipment monitoring and control
Utility Equipment Integrates multiple measurement points into a compact control system
Retrofit Projects Expands analog acquisition capacity in established M238 installations

Installation and Maintenance

  1. Confirm that the TM2AMI8HT is compatible with the existing Modicon M238 controller and TM2 expansion arrangement.
  2. Review the electrical drawings and identify each field device assigned to the analog inputs.
  3. Isolate the relevant control-system power before installing or removing the module.
  4. Verify the intended input assignments before connecting field wiring.
  5. Inspect sensor and transmitter wiring for loose terminals, damaged conductors, or incorrect connections.
  6. Keep analog signal wiring appropriately separated from high-power circuits and other significant sources of electrical interference.
  7. Install the module correctly within the M238 expansion arrangement and verify that the connection is fully seated.
  8. Confirm that the controller project contains the appropriate hardware and input configuration.
  9. Restore system power and verify that the M238 controller recognizes the expansion hardware correctly.
  10. Compare the acquired values with the corresponding field measurements during commissioning.
  11. If an input value is abnormal, check the field device, wiring, module connection, configuration, and controller diagnostics systematically.
  12. Record the module model, input assignments, and associated field devices for future maintenance and troubleshooting.

Related Components

Component Function in the System
Schneider Modicon M238 Controller Executes the main machine or process control program
Schneider TM2 Digital I/O Modules Provides discrete input and output expansion
Schneider TM2 Analog Input Modules Adds additional analog measurement acquisition
Schneider TM2 Analog Output Modules Provides analog command signals to compatible field devices
Field Sensors Generates analog measurement signals
Signal Transmitters Sends conditioned process measurements to the input interface
Terminal Blocks Provides organized field wiring termination
HMI Displays process values, alarms, and machine status
Drives / Actuators Responds to control commands generated by the M238 system

Recommended Related Models

Model Product Type Typical Relationship
Schneider TM2AMI2HT Modicon M238 Analog Input Module Related analog input expansion model
Schneider TM2AMI4HTN Modicon M238 Analog Input Module Related analog input expansion model
Schneider TM2ALM3LT Modicon M238 Analog Input/Output Module Related M238 analog I/O expansion
Schneider TM2AMO1HT Modicon M238 Analog Output Module Complementary analog output expansion
Schneider TM2AMI8HT Modicon M238 Analog Input Module Same model family and analog acquisition function

Key Advantages

  • Expands analog acquisition capacity within the Modicon M238 architecture.
  • Provides a dedicated interface for multiple continuous field measurements.
  • Integrates with the modular TM2 expansion system.
  • Supports sensors and transmitters used in machine and process automation.
  • Allows multiple analog process values to participate in M238 control logic.
  • Can be combined with digital and other analog I/O modules to build a complete machine interface.

Technical FAQs

What is the main purpose of the TM2AMI8HT?

The TM2AMI8HT is used to acquire analog measurement signals from compatible field sensors and transmitters and make those measurements available to a Modicon M238 controller.

Why use an analog input expansion module instead of a digital input module?

Digital inputs are intended for discrete states such as ON/OFF or open/closed. An analog input module is used when the controller needs to acquire a continuously varying measurement, such as a process value from an appropriate sensor or transmitter.

How should multiple analog measurement points be organized?

Each field device should be mapped to the appropriate input according to the application’s electrical drawings and controller configuration. Clear channel labeling and consistent field-device documentation make commissioning and later troubleshooting easier.

What should be checked before replacing a TM2AMI8HT?

The existing M238 hardware configuration, field-device connections, input assignments, wiring, controller project, and replacement module compatibility should all be verified. After installation, the individual analog measurements should be checked against the corresponding field values.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501