Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The GE UR 8AH is a Multilin UR Series CT/VT Module used to interface current transformer and voltage transformer signals with a GE Multilin Universal Relay system. It forms part of the relay’s measurement input path, allowing electrical quantities from the protected circuit to be brought into the relay for protection, metering, monitoring, and control functions.
In a typical substation, switchgear, generator, motor, or feeder application, CT and VT signals are routed from the power system through the appropriate instrument-transformer circuits and into the relay. The UR 8AH provides the corresponding module-level interface within the UR platform.
Because CT/VT inputs are fundamental to many protection functions, correct wiring, phase identification, configuration, and signal verification are particularly important when installing or replacing this module.
| Parameter | Specification |
|---|---|
| Product Model | UR 8AH |
| Product Type | Multilin UR Series CT/VT Module |
| Series | Multilin UR |
| I/O Function | CT / VT Signal Interface |
| Dimensions | 120 × 30 × 100 mm |
| Weight | 1.15 kg |
The UR 8AH receives measurement signals originating from external current transformers and voltage transformers. These signals enter the CT/VT interface and are passed into the Multilin UR relay’s internal measurement and processing architecture.
The relay uses the acquired electrical quantities according to its configured protection and monitoring functions. Depending on the application, the measured information can contribute to functions such as overcurrent protection, voltage supervision, power measurement, fault analysis, and control logic.
The module is therefore part of a complete measurement chain rather than an independent protection device. During commissioning, technicians should verify the instrument-transformer circuits, polarity and phase relationships, module connections, and relay configuration together. An incorrect CT or VT connection can produce abnormal measurements even when the relay and module are functioning normally.
| Architecture Layer | Role of UR 8AH |
|---|---|
| Power System | Provides the electrical quantities being monitored or protected |
| CT / VT Transformers | Produce scaled current and voltage signals for the relay |
| Instrument Transformer Wiring | Carries the measurement signals to the relay |
| UR 8AH | Provides the CT/VT interface within the UR platform |
| Multilin UR Relay | Processes current and voltage measurements |
| Protection Logic | Uses the measurements for configured protection functions |
| Metering / SCADA | Uses relay measurements for monitoring and system supervision |
The UR 8AH sits at the measurement-input layer of the architecture. Its correct operation depends on the external CT/VT circuits and the configuration of the host Multilin UR relay.
| Application | Typical Use |
|---|---|
| Substation Protection | Providing CT/VT measurements to a UR protection relay |
| Feeder Protection | Supplying current and voltage information for feeder monitoring and protection |
| Generator Protection | Integrating generator-side electrical measurements with relay functions |
| Motor Protection | Providing electrical measurement inputs for motor protection applications |
| Switchgear Protection | Connecting instrument-transformer circuits to the relay platform |
| Industrial Power Distribution | Supporting protection and metering of industrial electrical equipment |
| Electrical Monitoring | Providing current and voltage information for relay-based measurement and supervision |
| Component | Relationship |
|---|---|
| GE Multilin UR Protection Relays | Host platform for the CT/VT module |
| Current Transformers | Provide current measurement signals to the relay |
| Voltage Transformers | Provide voltage measurement signals to the relay |
| GE Multilin UR I/O Modules | Related modules used to configure relay inputs and outputs |
| Protection Test Equipment | Used to verify CT/VT measurement channels during commissioning |
| SCADA Systems | Receive measurement and protection information from the relay |
| Switchgear Control Equipment | Works with the relay in integrated protection and control systems |
| Model | Product Type | Application Relationship |
|---|---|---|
| GE UR 8AH | Multilin UR Series CT/VT Module | CT/VT measurement interface for UR relay systems |
| GE Multilin UR CT/VT Modules | CT/VT Input Module | Related measurement-input options for UR systems |
| GE Multilin UR Protection Relays | Universal Relay | Host platform for modular CT/VT and I/O functions |
| GE Multilin UR Feeder Relays | Feeder Protection Relay | Related platform for feeder CT/VT measurement and protection |
| GE Multilin UR Generator Relays | Generator Protection Relay | Related platform for generator electrical measurement and protection |
The UR 8AH is a Multilin UR Series CT/VT Module that provides the interface between external current and voltage transformer circuits and the host UR relay.
CT and VT connections determine the current and voltage information received by the relay. Incorrect phase assignment, polarity, or wiring can produce incorrect measurements and may affect protection functions even when the module itself is operating normally.
Possible symptoms include missing measurements, incorrect phase values, unexpected current or voltage readings, or inconsistencies between relay measurements and the electrical system. The CT/VT circuits, wiring, module connections, and relay configuration should be checked as a complete signal path.
The UR 8AH serves as the CT/VT interface. The host Multilin UR relay processes the received electrical measurements and applies the configured protection, metering, monitoring, and control functions.